胎儿心脏轴与V征角度在孕早期重大心脏缺陷筛查中的贡献
本队列研究纳入30例重大心脏缺陷胎儿与1538例正常胎儿,在孕早期测量四腔心切面心脏轴(CAx)和三血管气管切面V征角度(VSA)。正常胎儿CAx为30°至60°、VSA为30°至40°;异常CAx或VSA在心脏缺陷胎儿中占93.3%(28/30),在无心脏缺陷胎儿中占7.3%(113/1538)。作者认为CAx与VSA评估有助于界定孕早期重大心脏缺陷的风险人群。
要点
- 正常胎儿CAx参考范围为30°至60°,VSA为30°至40°。
- 重大心脏缺陷胎儿中异常CAx或VSA占93.3%(28/30),无缺陷胎儿中占7.3%(113/1538)。
- CAx与VSA评估有助于界定孕早期重大心脏缺陷的风险人群。
核心结论
- 评估胎儿心脏轴(CAx)与V征角度(VSA)有助于界定孕早期重大心脏缺陷的风险人群。
研究设计与样本
- 队列研究,2015年12月至2016年6月招募单胎妊娠且头臀长45至84 mm的孕妇接受颈项透明层超声检查,研究人群包括30例重大心脏缺陷胎儿和1538例正常胎儿。
关键影像表现/征象
- 在四腔心切面测量心脏轴(CAx),在三血管气管切面多普勒模式下测量V征角度(VSA)。
- 正常胎儿中CAx的2.5th至97.5th百分位范围为30°至60°,VSA为30°至40°。
诊断标准与关键数值
- 排除孤立性室间隔缺损和孤立性右位主动脉弓病例后,颈项透明层高于95th百分位在重大心脏缺陷胎儿中占63.3%(19/30),无心脏缺陷胎儿中占4.6%(71/1538)。
- 异常CAx在重大心脏缺陷胎儿中占63.3%(19/30),无心脏缺陷胎儿中占2.0%(30/1538)。
- 异常VSA在重大心脏缺陷胎儿中占66.7%(20/30),无心脏缺陷胎儿中占5.6%(86/1538)。
- 异常CAx或VSA在重大心脏缺陷胎儿中占93.3%(28/30),无心脏缺陷胎儿中占7.3%(113/1538)。
临床应用与阅片要点
- 在孕早期颈项透明层超声检查中,可于四腔心切面测量CAx、三血管气管切面多普勒模式下测量VSA,联合颈项透明层评估重大心脏缺陷风险。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To estimate the potential value of fetal assessment for the cardiac axis (CAx) and V-sign angle (VSA) in the first trimester in the prediction of fetal major cardiac defects.
METHODS: A cohort study was conducted from December 2015 to June 2016. Patients with singleton pregnancies and crown-rump length from 45 to 84 mm were recruited to undergo nuchal translucency sonography. The CAx on the 4-chamber view and the VSA on the 3-vessel and trachea view with Doppler mapping were measured. The estimated performance of different combinations of increased fetal nuchal translucency, CAx, and VSA in screening for major cardiac defects was examined.
RESULTS: The study population of fetuses included 30 fetuses with major cardiac defects and 1538 normal fetuses. The CAx and VSA were 30° to 60° and 30° to 40°, respectively, according to the 2.5th and 97.5th percentiles in normal fetuses. When cases of isolated septal wall defects and an isolated right aortic arch were excluded, nuchal translucency above the 95th percentile, an abnormal CAx, and an abnormal VSA were observed in 63.3% (19 of 30), 63.3% (19 of 30), and 66.7% (20 of 30) of fetuses with major cardiac defects, respectively, and in 4.6% (71 of 1538), 2.0% (30 of 1538), and 5.6% (86 of 1538) of those without cardiac defects. Either an abnormal CAx or VSA was found in 93.3% (28 of 30) of the fetuses with cardiac defects and in 7.3% (113 of 1538) of those without cardiac defects.
CONCLUSION: Assessment of the CAx and VSA is helpful in defining a population at risk for major cardiac defects in the first trimester.
引用
- Zheng MM, Tang HR, Zhang Y, et al. Contribution of the Fetal Cardiac Axis and V-Sign Angle in First-Trimester Screening for Major Cardiac Defects. J Ultrasound Med. 2018. PMID: 30208223. doi:10.1002/jum.14796
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。