胎儿心胸直径比的Z评分参考范围

Z Score Reference Ranges of Fetal Cardiothoracic Diameter Ratio.
PubMed 文献 · J Ultrasound Med · 2018-09-12

横断面研究纳入683例低危单胎妊娠健康胎儿,在14至40周经二维超声四腔心切面测量心胸直径比(CTR),以孕龄、双顶径和头围为自变量建立均数与标准差的Z评分参考范围。CTR随孕龄、双顶径和头围增大而轻度升高,所建列线图可能有助于检出心脏异常。

要点

  • 胎儿CTR随孕龄、双顶径和头围增加而轻度升高,报告时需按相应自变量换算Z评分。
  • 已建立以孕龄(周)、双顶径(cm)、头围(cm)为自变量的CTR均数与标准差方程,可用于计算Z评分。
  • 列线图可能有助于检出心脏异常,原文未报告诊断敏感度或特异度。

核心结论

  • 建立了覆盖全孕期的CTR Z评分参考范围列线图,原文认为这些列线图可能有助于检出心脏异常。

研究设计与样本

  • 横断面研究,纳入低危单胎妊娠且胎儿健康的孕妇,共测量683例胎儿。
  • 采用简单二维超声在典型胎儿四腔心切面测量CTR。
  • 以孕龄、双顶径和头围为独立变量,基于最佳拟合模型分别构建均数与标准差的参考范围。

关键影像表现/征象

  • CTR随孕龄、双顶径和头围增大而轻度升高。

诊断标准与关键数值

  • CTR均值与标准差方程(孕龄):CTR=0.365+0.004×孕龄(周),标准差=0.031+0.001×孕龄(周)。
  • CTR均值与标准差方程(双顶径):CTR=0.373+0.014×双顶径(cm),标准差=0.034+0.004×双顶径(cm)。
  • CTR均值与标准差方程(头围):CTR=0.373+0.004×头围(cm),标准差=0.032+0.001×头围(cm)。

临床应用与阅片要点

  • 原文未据此给出具体阅片或报告操作建议。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aims to establish the z score reference ranges of cardiothoracic diameter ratio (CTR) of normal fetuses from 14 to 40 weeks' gestation.

METHOD: A cross-sectional study was conducted on low-risk singleton pregnancies with healthy fetuses. The CTR was performed using simple 2-dimensional sonography on the typical fetal 4-chamber view. The reference ranges were constructed according to gestational age (GA), biparietal diameter (BPD), and head circumference (HC) as independent variables based on the best-fit models, both mean and standard deviation (SD).

RESULTS: A total of 683 fetuses were measured for CTR. The best-fit equations for the mean and SD as a function of GA, BPD, and HC are as follows: (1) CTR = 0.365 + 0.004 × GA in weeks (SD = 0.031 + 0.001 × GA); (2) CTR = 0.373 + 0.014 × BPD in cm (SD = 0.034 + 0.004 × BPD); and (3) CTR = 0.373 + 0.004 × HC in cm (SD = 0.032 + 0.001 × HC). The CTR was slightly increased with advanced GA, BPD, and HC.

CONCLUSION: Complete nomograms with z score reference ranges of CTR were established throughout pregnancy. These nomograms may be useful to detect cardiac abnormalities.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Sirilert S, Tongprasert F, Srisupundit K, et al. Z Score Reference Ranges of Fetal Cardiothoracic Diameter Ratio. J Ultrasound Med. 2018. PMID: 30208233. doi:10.1002/jum.14786

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。