文献速递心血管CT

解剖与功能CT诊断血流动力学显著冠状动脉疾病:一项Meta分析

Anatomical and Functional Computed Tomography for Diagnosing Hemodynamically Significant Coronary Artery Disease: A Meta-Analysis.
PubMed 文献 · JACC Cardiovasc Imaging · 2018-09-12

该Meta分析纳入54篇文献、5330例患者,以FFR为参考标准,评估CTA、CTP、FFRCT、TAG及联合CTA的诊断性能。血管水平上,CTP、FFRCT、TAG的特异度均高于CTA,联合CTA后特异度达0.80~0.92;CTP和FFRCT较CTA明显改善对血流动力学显著CAD的识别,作者推荐在血运重建前将其整合入临床流程。

要点

  • 血管水平上,CTP、FFRCT和TAG的特异度均高于CTA,联合CTA后特异度达0.80~0.92。
  • CTP、FFRCT及CTA联合CTP的血管水平诊断准确性优于CTA。
  • 动态CTP较静态CTP敏感度更高但特异度更低,作者推荐血运重建前整合功能CT。

核心结论

  • CTP和FFRCT较CTA明显改善对血流动力学显著CAD的识别。
  • 作者推荐在血运重建前将CTP和FFRCT整合入临床流程。

研究设计与样本

  • 研究类型为Meta分析,遵循PRISMA指南,检索PubMed、EMBASE和Web of Science自建库至2017年9月7日。
  • 共纳入54篇文献、5330例患者,采用贝叶斯随机效应分析计算合并敏感度、特异度及SROC曲线。
  • 以FFR为参考标准,在血管水平和患者水平进行分析,并收集个体FFRCT值。

诊断标准与关键数值

  • 血管水平合并特异度:CTP 0.86(95%CI 0.76~0.93)、FFRCT 0.78(95%CI 0.72~0.83)、TAG 0.77(95%CI 0.61~0.89),均高于CTA 0.61(95%CI 0.54~0.68)。
  • FFRCT、CTP和TAG联合CTA后特异度为0.80~0.92。
  • 血管水平SROC曲线显示CTP、FFRCT及CTA联合CTP的诊断准确性优于CTA。
  • 在场与离场FFRCT亚组分析:敏感度0.84 vs 0.85,特异度0.80 vs 0.73,两种技术间无实质差异。
  • 动态CTP较静态CTP敏感度更高(0.85 vs 0.72),但特异度更低(0.81 vs 0.90)。

临床应用与阅片要点

  • 作者推荐在血运重建前将CTP和FFRCT整合入临床流程,以改善对血流动力学显著CAD的识别。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This meta-analysis determined the diagnostic performance of coronary computed tomography (CT) angiography (CTA), CT myocardial perfusion (CTP), fractional flow reserve CT (FFRCT), the transluminal attenuation gradient (TAG), and their combined use with CTA versus FFR as a reference standard for detection of hemodynamically significant coronary artery disease (CAD).

BACKGROUND: CTA provides excellent anatomic, albeit limited functional information for the evaluation of CAD. Recently, various functional CT techniques emerged to assess the hemodynamic consequences of CAD.

METHODS: This meta-analysis was performed in adherence to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. PubMed, EMBASE, and Web of Science were searched from inception until September 7, 2017. Bayesian random effects analysis was used to compute pooled sensitivity, specificity, and the summary receiver-operating characteristic curve of the index tests and compare them with the FFR as a reference standard. Analyses were performed on vessel and patient levels. Because CTA has excellent sensitivity, specificity was considered most relevant. Individual FFRCT values were collected.

RESULTS: Overall, 54 articles and 5,330 patients were included. At vessel level, pooled specificity of CTP (0.86; 95% confidence interval [CI]: 0.76 to 0.93), FFRCT (0.78; 95% CI: 0.72 to 0.83) and TAG (0.77; 95% CI: 0.61 to 0.89) were substantially higher than that of CTA (0.61; 95% CI: 0.54 to 0.68). The addition of FFRCT, CTP, and TAG to CTA resulted in high to excellent specificities (0.80 to 0.92). The summary receiver-operating characteristic curve at vessel level yielded superior diagnostic accuracy for CTP, FFRCT, and combined CTA and CTP, compared with CTA. A subanalysis of on-site versus off-site FFRCT revealed no substantial differences between the sensitivity (0.84 vs. 0.85) and specificity (0.80 vs. 0.73) of the 2 techniques. In a second subanalysis, dynamic CTP showed higher sensitivity (0.85 vs. 0.72), but had a lower specificity (0.81 vs. 0.90) than static CTP.

CONCLUSIONS: CTP and FFRCT demonstrated a substantial improvement in the identification of hemodynamically significant CAD compared with CTA; therefore, their integration to clinical workflow before revascularization is recommended.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Celeng C, Leiner T, Maurovich-Horvat P, et al. Anatomical and Functional Computed Tomography for Diagnosing Hemodynamically Significant Coronary Artery Disease: A Meta-Analysis. JACC Cardiovasc Imaging. 2018. PMID: 30219398. doi:10.1016/j.jcmg.2018.07.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。