基于二尖瓣运动的收缩功能估测:急诊医师在呼吸困难患者中的精准床旁工具
这项前瞻性观察研究纳入118例以呼吸困难为主诉的成人患者,测量二尖瓣前叶与室间隔距离等4项二尖瓣运动指标,并与经验丰富的心脏科医师完成的完整超声心动图所测左心室射血分数(LVEF)进行相关分析。结果显示胸骨旁长轴B型二尖瓣前叶室间隔分离、E点室间隔分离和心尖四腔B型二尖瓣前叶室间隔分离与LVEF高度相关(相关系数分别为-0.848、-0.833、-0.822,P<.001),部分阈值排除LVEF减低或严重减低时阴性预测值达100%。作者认为二尖瓣测量法可能有助于预测LVEF,作为超声图像困难患者的补充诊断方法。
要点
- 胸骨旁长轴B型二尖瓣前叶室间隔分离与LVEF相关系数为-0.848(P<.001),是4项指标中相关性最高者。
- 该指标<2.30 mm、E点室间隔分离<2 mm、二尖瓣叶分离>25.15 mm时,排除LVEF减低的阴性预测值均为100%。
- 该指标<4.95 mm、E点室间隔分离<5.85 mm、心尖四腔B型二尖瓣前叶室间隔分离<6.95 mm、二尖瓣叶分离>24.05 mm时,排除LVEF严重减低的阴性预测值均为100%。
核心结论
- 二尖瓣测量方法可能有助于预测LVEF或其数值,可作为超声图像困难患者的补充诊断方法。
研究设计与样本
- 前瞻性观察研究,纳入118例以呼吸困难为主诉的成人患者;由经验丰富的心脏科医师完成完整超声心动图作为参照,并计算二尖瓣测量值与LVEF的相关性,采用受试者工作特征曲线和卡方检验确定截断值。
关键影像表现/征象
- 胸骨旁长轴B型测量二尖瓣前叶至室间隔距离,命名为胸骨旁长轴二尖瓣前叶室间隔分离。
- 胸骨旁长轴M型测量二尖瓣前叶至室间隔距离,命名为E点室间隔分离。
- 心尖四腔B型测量二尖瓣前叶至室间隔距离,命名为心尖四腔二尖瓣前叶室间隔分离。
- 心尖四腔测量两枚二尖瓣叶之间最大距离,命名为二尖瓣叶分离。
诊断标准与关键数值
- 胸骨旁长轴二尖瓣前叶室间隔分离、E点室间隔分离、心尖四腔二尖瓣前叶室间隔分离与LVEF的相关系数分别为-0.848、-0.833、-0.822(P<.001)。
- 胸骨旁长轴二尖瓣前叶室间隔分离<2.30 mm、E点室间隔分离<2 mm、二尖瓣叶分离>25.15 mm时,排除LVEF减低的阴性预测值为100%。
- 胸骨旁长轴二尖瓣前叶室间隔分离<4.95 mm、E点室间隔分离<5.85 mm、心尖四腔二尖瓣前叶室间隔分离<6.95 mm、二尖瓣叶分离>24.05 mm时,排除LVEF严重减低的阴性预测值为100%。
临床应用与阅片要点
- 作者认为二尖瓣测量方法可能有助于预测LVEF或其数值,可作为超声图像困难患者的补充诊断方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The purpose of this study was to determine the success of mitral valve movements in the estimation of left ventricular ejection fraction (LVEF).
METHODS: Adult patients whose principal symptom was dyspnea were included in this prospective observational study. The distance from the anterior mitral valve (AMV) to the interventricular septum (IVS) during early diastole was measured first in B-mode in the parasternal long axis (PLAX) named parasternal long axis-anterior leaflet septal separation. Second, the AMV-IVS distance was measured in M-mode in the PLAX named E-point septal separation. Third, AMV-IVS distance was measured in B-mode in the apical 4-chamber view named apical 4-chamber view-anterior leaflet septal separation. Finally, maximum distance between the 2 mitral leaflets in the apical 4-chamber view was measured and named mitral valve leaflet separation. Comprehensive echocardiography was performed by an experienced cardiologist. Correlation was calculated between mitral valve measurements and LVEF. Cutoff values were determined using receiver operating characteristic curves and the chi-square test.
RESULTS: A total of 118 patients were included in the study. Parasternal long axis-anterior leaflet septal separation, E-point septal separation, and apical 4-chamber view-anterior leaflet septal separation were highly correlated with LVEF (correlation coefficient, -0.848, -0.833, and-0.822 [P < .001]). Parasternal long axis-anterior leaflet septal separation values less than 2.30 mm, E-point septal separation values less than 2 mm, and mitral valve leaflet separation values greater than 25.15 mm exhibited a 100% negative predictive value in excluding reduced LVEF. Parasternal long axis-anterior leaflet septal separation values less than 4.95 mm, EPSS values less than 5.85 mm, apical 4-chamber view-anterior leaflet septal separation values less than 6.95 mm, and mitral valve leaflet separation values greater than 24.05 mm exhibited a 100% negative predictive value in excluding severe reduced LVEF.
CONCLUSIONS: Mitral valve measurement methods may be useful in predicting LVEF or values thereof as a complementary method of diagnosing challenging patients on echocardiographic images.
引用
- Satılmış Siliv N, Yamanoglu A, Pınar P, et al. Estimation of Cardiac Systolic Function Based on Mitral Valve Movements: An Accurate Bedside Tool for Emergency Physicians in Dyspneic Patients. J Ultrasound Med. 2018. PMID: 30265408. doi:10.1002/jum.14791
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。