鉴别良恶性实性孤立性肺病变:体素内不相干运动与扩散峰度成像是否优于传统扩散加权成像
研究纳入89例实性孤立性肺病变患者,在3-T磁共振上行多b值DWI和DKI,比较单指数、双指数及DKI各参数鉴别良恶性的价值。D*、f、Kapp两组无统计学显著差异。ADCtotal的AUC最高(0.862),但各参数间诊断效能差异无统计学显著意义(p>0.05)。
要点
- 恶性实性孤立性肺病变的ADCtotal、D、Dapp及ADC(0,≥300)均低于良性病变,D*、f、Kapp两组无统计学显著差异。
- ADC(0,≥500)的鉴别效能优于ADC(0,<500),但IVIM与DKI各参数间诊断效能差异无统计学显著意义(p>0.05)。
核心结论
- IVIM和DKI衍生参数在鉴别实性孤立性肺病变方面与传统ADC表现相似。
研究设计与样本
- 采用3-T磁共振成像设备对89例实性孤立性肺病变患者行多b值DWI和DKI检查,计算单指数模型各b值组合的ADC、双指数模型参数D、D*、f以及DKI参数Kapp、Dapp,采用Mann-Whitney U检验比较恶性组与良性组,并对所有参数行受试者工作特征分析。
关键影像表现/征象
- D*、f、Kapp在恶性组与良性组间无统计学显著差异。
诊断标准与关键数值
- ADCtotal的AUC最高(AUC=0.862)。
- 各参数间诊断效能差异无统计学显著意义(p>0.05)。
临床应用与阅片要点
- 单指数、双指数DWI及DKI均可用于实性孤立性肺病变的良恶性鉴别。
- ADC(0,≥500)在评估实性孤立性肺病变方面表现优于ADC(0,<500)。
- IVIM和DKI在鉴别实性孤立性肺病变方面与传统DWI表现相似。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To quantitatively compare the diagnostic values of various diffusion parameters obtained from mono- and biexponential diffusion-weighted imaging (DWI) models and diffusion kurtosis imaging (DKI) in differentiating between benign and malignant solitary pulmonary lesions (SPLs).
METHODS: Multiple b-value DWIs and DKIs were performed in 89 patients with SPL by using a 3-T magnetic resonance (MR) imaging unit. The apparent diffusion coefficient (ADC) of various b-value sets, true diffusivity (D), pseudo-diffusion coefficient (D*), perfusion fraction (f), apparent diffusional kurtosis (Kapp), and kurtosis-corrected diffusion coefficient (Dapp) were calculated and compared between the malignant and benign groups using a Mann-Whitney U test. Receiver-operating characteristic analysis was performed for all parameters.
RESULT: The ADC(0, 150) values of malignant tumors were lower than those of the benign group (p = 0.01). The ADC(0, 300), ADC(0, 500), ADC(0, 600), ADC(0, 800), ADC(0, 1000), ADCtotal, D, and Dapp of malignant tumors were significantly lower than those of benign lesions (all p < 0.001). D*, f, and Kapp showed no statistically significant differences between the two groups. ADCtotal showed the highest area under the curve (AUC = 0.862), followed by ADC(0, 800)(AUC = 0.844), ADC(0, 600)(AUC = 0.843), D(AUC = 0.834), ADC(0, 1000)(AUC = 0.834) and ADC(0, 500)(AUC = 0.824), Dapp(AUC = 0.796), and ADC(0, 300) (AUC = 0.773). However, the difference in diagnostic efficacy among these parameters was not statistically significant (p > 0.05).
CONCLUSION: Intravoxel incoherent motion (IVIM) and DKI-derived parameters have similar performance compared with conventional ADC in differentiating SPLs.
KEY POINTS: • Mono- and biexponential DWI and DKI are feasible for differentiating SPLs. • ADC (0, ≥500) has better performance than ADC (0, <500) in assessing SPLs. • IVIM and DKI have similar performance compared with conventional DWI in differentiating SPLs.
引用
- Wan Q, Deng YS, Lei Q, et al. Differentiating between malignant and benign solid solitary pulmonary lesions: are intravoxel incoherent motion and diffusion kurtosis imaging superior to conventional diffusion-weighted imaging? Eur Radiol. 2018. PMID: 30255258. doi:10.1007/s00330-018-5714-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。