基于模板数据增强的卷积神经网络用于功能性肺影像定量
研究提出基于深度学习的质子肺MRI自动分割与通气定量流程,采用模板数据增强策略训练CNN,在63例和40例图像上评估。全肺分割Dice为0.94±0.02,略低于联合标签融合的0.96±0.01,但处理时间从约30分钟/例降至不足1秒/例。通气缺损定量平均Dice为0.94,优于既往方法(0.92)和三位专家阅片者(0.90、0.92、0.94)。
要点
- 全肺质子MRI分割Dice为0.94±0.02,处理时间不足1秒/例。
- 通气缺损定量平均Dice为0.94,高于既往方法0.92和专家阅片者0.90–0.94。
- CNN分割精度略低于联合标签融合(全肺0.96±0.01),但速度大幅提升。
核心结论
- 所提框架可实现接近实时的自动定量,CNN在离线模型构建后大幅缩短处理时间,显示出促进功能性肺MRI定量分析的未来潜力。
研究设计与样本
- 研究构建并训练深度卷积神经网络模型,采用自定义多标签Dice损失函数和基于模板的数据增强策略。训练(含模板生成与数据增强)使用205幅质子MR图像和73幅功能性肺MRI,评估分别使用63幅和40幅图像的数据集。
诊断标准与关键数值
- CNN质子肺MRI分割Dice重叠:左肺0.93±0.03、右肺0.94±0.02、全肺0.94±0.02;联合标签融合:左肺0.95±0.02、右肺0.96±0.01、全肺0.96±0.01。通气缺损定量基于共识标注的平均Dice(通气缺损区加正常区的多标签重叠):CNN方法0.94、既往方法0.92、专家阅片者分别为0.90、0.92、0.94。
临床应用与阅片要点
- CNN方法全肺分割处理时间不足1秒/例,联合标签融合约30分钟/例。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: We propose an automated segmentation pipeline based on deep learning for proton lung MRI segmentation and ventilation-based quantification which improves on our previously reported methodologies in terms of computational efficiency while demonstrating accuracy and robustness. The large data requirement for the proposed framework is made possible by a novel template-based data augmentation strategy. Supporting this work is the open-source ANTsRNet-a growing repository of well-known deep learning architectures first introduced here.
MATERIALS AND METHODS: Deep convolutional neural network (CNN) models were constructed and trained using a custom multilabel Dice metric loss function and a novel template-based data augmentation strategy. Training (including template generation and data augmentation) employed 205 proton MR images and 73 functional lung MRI. Evaluation was performed using data sets of size 63 and 40 images, respectively.
RESULTS: Accuracy for CNN-based proton lung MRI segmentation (in terms of Dice overlap) was left lung: 0.93 ± 0.03, right lung: 0.94 ± 0.02, and whole lung: 0.94 ± 0.02. Although slightly less accurate than our previously reported joint label fusion approach (left lung: 0.95 ± 0.02, right lung: 0.96 ± 0.01, and whole lung: 0.96 ± 0.01), processing time is <1 second per subject for the proposed approach versus ∼30 minutes per subject using joint label fusion. Accuracy for quantifying ventilation defects was determined based on a consensus labeling where average accuracy (Dice multilabel overlap of ventilation defect regions plus normal region) was 0.94 for the CNN method; 0.92 for our previously reported method; and 0.90, 0.92, and 0.94 for expert readers.
CONCLUSION: The proposed framework yields accurate automated quantification in near real time. CNNs drastically reduce processing time after offline model construction and demonstrate significant future potential for facilitating quantitative analysis of functional lung MRI.
引用
- Tustison NJ, Avants BB, Lin Z, et al. Convolutional Neural Networks with Template-Based Data Augmentation for Functional Lung Image Quantification. Acad Radiol. 2018. PMID: 30195415. doi:10.1016/j.acra.2018.08.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。