文献速递胸部DR

基于深度学习的胸片恶性肺结节自动检测算法的开发与验证

Development and Validation of Deep Learning-based Automatic Detection Algorithm for Malignant Pulmonary Nodules on Chest Radiographs.
PubMed 文献 · Radiology · 2018-09-25

本研究回顾性开发并验证了一种基于深度学习的胸片恶性肺结节自动检测算法(DLAD),使用43292张胸片训练卷积神经网络,并在一个内部和四个外部数据集上验证。DLAD在胸片分类和结节检测方面的AUROC为0.92-0.99,JAFROC FOM为0.831-0.924,在观察者性能测试中表现优于多数医师,且所有医师使用DLAD后结节检测性能均得到提升。

要点

  • DLAD在内部和外部验证集上胸片分类AUROC为0.92-0.99,结节检测JAFROC FOM为0.831-0.924。
  • 在观察者测试中,DLAD的AUROC高于18名医师中的17名,JAFROC FOM高于18名医师中的15名(P < .05)。
  • 所有医师使用DLAD辅助后结节检测性能均提升(平均JAFROC FOM提高0.043,范围0.006-0.190,P < .05)。

核心结论

  • 该深度学习自动检测算法在胸片恶性肺结节的分类和检测性能上优于医师,作为第二读者时可提升医师的检测性能。

研究设计与样本

  • 回顾性研究,使用2010至2015年间34676例患者的43292张胸片(正常与结节片比34 067:9225)开发DLAD,由13名委员会认证放射科医师标注和部分注释,在卷积神经网络中训练;使用来自韩国三家医院和美国一家医院的一个内部和四个外部数据集进行验证;另用其中一个外部验证集对18名医师(包括9名委员会认证放射科医师)进行观察者性能测试。

诊断标准与关键数值

  • DLAD在内部和外部验证集上的胸片分类性能以AUROC评估,范围为0.92-0.99;结节检测性能以JAFROC FOM评估,范围为0.831-0.924。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To develop and validate a deep learning-based automatic detection algorithm (DLAD) for malignant pulmonary nodules on chest radiographs and to compare its performance with physicians including thoracic radiologists. Materials and Methods For this retrospective study, DLAD was developed by using 43 292 chest radiographs (normal radiograph-to-nodule radiograph ratio, 34 067:9225) in 34 676 patients (healthy-to-nodule ratio, 30 784:3892; 19 230 men [mean age, 52.8 years; age range, 18-99 years]; 15 446 women [mean age, 52.3 years; age range, 18-98 years]) obtained between 2010 and 2015, which were labeled and partially annotated by 13 board-certified radiologists, in a convolutional neural network. Radiograph classification and nodule detection performances of DLAD were validated by using one internal and four external data sets from three South Korean hospitals and one U.S. hospital. For internal and external validation, radiograph classification and nodule detection performances of DLAD were evaluated by using the area under the receiver operating characteristic curve (AUROC) and jackknife alternative free-response receiver-operating characteristic (JAFROC) figure of merit (FOM), respectively. An observer performance test involving 18 physicians, including nine board-certified radiologists, was conducted by using one of the four external validation data sets. Performances of DLAD, physicians, and physicians assisted with DLAD were evaluated and compared. Results According to one internal and four external validation data sets, radiograph classification and nodule detection performances of DLAD were a range of 0.92-0.99 (AUROC) and 0.831-0.924 (JAFROC FOM), respectively. DLAD showed a higher AUROC and JAFROC FOM at the observer performance test than 17 of 18 and 15 of 18 physicians, respectively (P < .05), and all physicians showed improved nodule detection performances with DLAD (mean JAFROC FOM improvement, 0.043; range, 0.006-0.190; P < .05). Conclusion This deep learning-based automatic detection algorithm outperformed physicians in radiograph classification and nodule detection performance for malignant pulmonary nodules on chest radiographs, and it enhanced physicians' performances when used as a second reader. © RSNA, 2018 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Nam JG, Park S, Hwang EJ, et al. Development and Validation of Deep Learning-based Automatic Detection Algorithm for Malignant Pulmonary Nodules on Chest Radiographs. Radiology. 2018. PMID: 30251934. doi:10.1148/radiol.2018180237

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。