静态数字胸部断层融合在成人囊性纤维化患者中的初步临床评估
本研究纳入14例接受临床指征胸片检查的囊性纤维化患者,在胸片检查72小时内行基于碳纳米管线性X射线源阵列的静态数字胸部断层融合(s-DCT)成像,由3名放射科医师评估图像质量,并以Brasfield评分和断层融合疾病严重度评分评估疾病严重程度,与肺功能检查对比。结果显示s-DCT对近端支气管、小气道和血管纹理的显示优于胸片,断层融合疾病严重度评分与FEV1、FEF 25-75%及FVC均呈负相关。
要点
- s-DCT对近端支气管、小气道和血管纹理的显示评分高于胸片。
- 断层融合疾病严重度评分与FEV1(r=-0.685)、FEF 25-75%(r=-0.719)及FVC(r=-0.582)呈负相关。
- 平均Brasfield评分与平均断层融合疾病严重度评分相关系数为-0.73(p=0.0033)。
核心结论
- 基于碳纳米管X射线的s-DCT在囊性纤维化疾病状态评估中具有潜力,可在较低剂量下改善重要肺部特征的显示并与肺功能检查高度相关。
研究设计与样本
- 首次s-DCT临床研究,纳入14例接受临床指征胸片检查的囊性纤维化患者,在胸片检查72小时内行s-DCT成像;由3名委员会认证的放射科医师评估图像质量;以Brasfield评分(胸片)和胸部断层融合评分(s-DCT)评估疾病严重程度,并与肺功能检查对比。
关键影像表现/征象
- s-DCT对近端支气管、小气道和血管纹理的显示评分高于胸片。
- 尽管该原型系统角度跨度短,s-DCT对近端支气管、小气道和肺血管等肺部特征的显示仍优于胸片。
诊断标准与关键数值
- 平均Brasfield评分与平均断层融合疾病严重度评分相关系数为-0.73(p=0.0033)。
- 断层融合疾病严重度评分与FEV1相关系数r=-0.685,与FEF 25-75%相关系数r=-0.719,与FVC相关系数r=-0.582。
临床应用与阅片要点
- 基于碳纳米管线性阵列X射线断层融合系统无需移动机架即可为囊性纤维化患者提供诊断相关信息。
- s-DCT可在较低剂量下改善近端支气管、小气道和肺血管的显示,并用于评估囊性纤维化疾病严重程度。
- 预期采用更长线性X射线阵列管可进一步改善成像。
局限性
- 该原型系统角度跨度短。
- 样本量为14例。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The imaging evaluation of cystic fibrosis currently relies on chest radiography or computed tomography. Recently, digital chest tomosynthesis has been proposed as an alternative. We have developed a stationary digital chest tomosynthesis (s-DCT) system based on a carbon nanotube (CNT) linear x-ray source array. This system enables tomographic imaging without movement of the x-ray tube and allows for physiological gating. The goal of this study was to evaluate the feasibility of clinical CF imaging with the s-DCT system.
MATERIALS AND METHODS: CF patients undergoing clinically indicated chest radiography were recruited for the study and imaged on the s-DCT system. Three board-certified radiologists reviewed both the CXR and s-DCT images for image quality relevant to CF. CF disease severity was assessed by Brasfield score on CXR and chest tomosynthesis score on s-DCT. Disease severity measures were also evaluated against subject pulmonary function tests.
RESULTS: Fourteen patients underwent s-DCT imaging within 72 h of their chest radiograph imaging. Readers scored the visualization of proximal bronchi, small airways and vascular pattern higher on s-DCT than CXR. Correlation between the averaged Brasfield score and averaged tomosynthesis disease severity score for CF was -0.73, p = 0.0033. The CF disease severity score system for tomosynthesis had high correlation with FEV1 (r = -0.685) and FEF 25-75% (r = -0.719) as well as good correlation with FVC (r = -0.582).
CONCLUSION: We demonstrate the potential of CNT x-ray-based s-DCT for use in the evaluation of cystic fibrosis disease status in the first clinical study of s-DCT.
KEY POINTS: • Carbon nanotube-based linear array x-ray tomosynthesis systems have the potential to provide diagnostically relevant information for patients with cystic fibrosis without the need for a moving gantry. • Despite the short angular span in this prototype system, lung features such as the proximal bronchi, small airways and pulmonary vasculature have improved visualization on s-DCT compared with CXR. Further improvements are anticipated with longer linear x-ray array tubes. • Evaluation of disease severity in CF patients is possible with s-DCT, yielding improved visualization of important lung features and high correlation with pulmonary function tests at a relatively low dose.
引用
- Gunnell ET, Franceschi DK, Inscoe CR, et al. Initial clinical evaluation of stationary digital chest tomosynthesis in adult patients with cystic fibrosis. Eur Radiol. 2018. PMID: 30255248. doi:10.1007/s00330-018-5703-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。