文献速递头颈神经MR

扩散加权成像鉴别头颈部鳞状细胞癌转移性淋巴结的诊断价值:系统评价与Meta分析

The Diagnostic Value of Diffusion-Weighted Imaging in Differentiating Metastatic Lymph Nodes of Head and Neck Squamous Cell Carcinoma: A Systematic Review and Meta-Analysis.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-09-13

该系统评价与Meta分析纳入9项研究共337例患者,评估DWI鉴别头颈部鳞状细胞癌转移性与良性颈部淋巴结的诊断效能。转移性淋巴结ADC值显著低于良性淋巴结,中位ADC阈值为0.965×10-3 mm2/s,汇总敏感度和特异度分别为90%(95%CI 84%-94%)和88%(95%CI 80%-93%)。

要点

  • 转移性淋巴结ADC值显著低于良性淋巴结,中位ADC阈值为0.965×10-3 mm2/s。
  • DWI鉴别转移性与良性淋巴结的汇总敏感度90%、特异度88%。
  • 3 mm层厚DWI研究的敏感度93%高于层厚>3 mm研究的86%(P<.01)。

核心结论

  • DWI在鉴别头颈部鳞状细胞癌患者转移性与良性淋巴结方面表现出高诊断效能,中位ADC阈值为0.965×10-3 mm2/s;3 mm DWI层厚可略微提高敏感度。

研究设计与样本

  • 系统评价与Meta分析,纳入9项原始研究共337例患者,检索Ovid MEDLINE和EMBASE,采用双变量随机效应模型及分层汇总受试者工作特征曲线进行诊断性Meta分析,并行Meta回归。

关键影像表现/征象

  • 所有研究中,转移性淋巴结的ADC值均显著低于良性淋巴结。

诊断标准与关键数值

  • DWI鉴别转移性与良性淋巴结的汇总敏感度为90%(95%CI 84%-94%),汇总特异度为88%(95%CI 80%-93%)。
  • 中位ADC阈值为0.965×10-3 mm2/s。
  • Meta回归显示,3 mm层厚研究的敏感度为93%(95%CI 88%-98%),高于层厚>3 mm研究的86%(95%CI 77%-95%),P<.01。

局限性

  • 本Meta分析纳入的研究数量较少。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Accurate lymph node staging is crucial for proper treatment planning for metastasis in patients with head and neck squamous cell carcinoma.

PURPOSE: Our aim was to evaluate the diagnostic performance of DWI for differentiating metastatic cervical lymph nodes from benign cervical lymph nodes in patients with head and neck squamous cell carcinoma and to identify optimal cutoff values for ADC.

DATA SOURCES: A computerized literature search was performed to identify relevant original articles in Ovid MEDLINE and EMBASE.

STUDY SELECTION: Studies evaluating the diagnostic performance of DWI for differentiating metastatic cervical lymph nodes from benign cervical lymph nodes were selected.

DATA ANALYSIS: Diagnostic meta-analysis was conducted with a bivariate random-effects model, and a hierarchical summary receiver operating characteristic curve was obtained. Meta-regression was also performed.

DATA SYNTHESIS: Nine studies with 337 patients were included. In all studies, ADC values derived from metastatic lymph nodes were significantly lower than ADC values derived from benign lymph nodes. The median ADC cutoff value was 0.965 × 10-3 mm2/s. The pooled sensitivity and specificity for the diagnostic performance of DWI in differentiating metastatic lymph nodes from benign lymph nodes were 90% (95% CI, 84%-94%) and 88% (95% CI, 80%-93%), respectively. In the meta-regression, sensitivity was significantly higher in the studies using a 3-mm slice thickness (93% [95% CI, 88%-98%]) than in studies using a slice thickness of >3 mm (86% [95% CI, 77%-95%], P < .01).

LIMITATIONS: A small number of studies were included in our meta-analysis.

CONCLUSIONS: DWI demonstrated high diagnostic performance for differentiating metastatic lymph nodes from benign lymph nodes in patients with head and neck squamous cell carcinoma, and the median ADC cutoff value was 0.965 × 10-3 mm2/s. A 3-mm DWI slice thickness can provide a slight improvement in sensitivity.