文献速递头颈技术与安全CT

自适应4D容积灌注CT检测头颈部鳞状细胞癌转移性颈部淋巴结的诊断效能

Diagnostic Performance of Adaptive 4D Volume Perfusion CT for Detecting Metastatic Cervical Lymph Nodes in Head and Neck Squamous Cell Carcinoma.
PubMed 文献 · AJR Am J Roentgenol · 2018-09-21

本研究纳入30例组织学确诊的头颈部鳞状细胞癌患者,分析灌注参数与淋巴结大小的关系,并比较转移性与良性淋巴结的灌注参数。结果显示血流量、血容量和渗透表面积乘积与转移性淋巴结大小呈显著负相关,血流量鉴别转移性与良性淋巴结的敏感度和特异度分别为73.3%和70.8%。作者认为覆盖全颈的4D容积灌注CT可能有助于颈部淋巴结表征,值得将其纳入头颈部鳞状细胞癌的淋巴结分期。

要点

  • 转移性淋巴结的血流量、血容量和渗透表面积乘积与淋巴结大小呈显著负相关。
  • 最大径<10mm的转移性淋巴结血流量显著高于良性淋巴结(p=0.02)。
  • 血流量鉴别转移性与良性淋巴结的敏感度73.3%、特异度70.8%。

核心结论

  • 覆盖全颈的4D容积灌注CT可能有助于颈部淋巴结表征,值得将其纳入头颈部鳞状细胞癌的淋巴结分期。

研究设计与样本

  • 研究纳入30例组织学确诊的头颈部鳞状细胞癌患者,采用自适应4D容积灌注CT覆盖全颈,分析灌注参数与淋巴结大小的关系并比较转移性与良性淋巴结的灌注参数。

关键影像表现/征象

  • 转移性淋巴结的血流量(r=-0.40,p=0.002)、血容量(r=-0.32,p=0.02)和渗透表面积乘积(r=-0.27,p=0.04)与淋巴结大小呈显著负相关。
  • 淋巴结最大径<10mm时,血流量、血容量和渗透表面积乘积均显著高于最大径≥10mm者(血流量p=0.004;血容量p=0.01;渗透表面积乘积p=0.02)。
  • 最大径<10mm的淋巴结中,转移性淋巴结血流量显著高于良性淋巴结(p=0.02)。
  • 最大径≥10mm的淋巴结中,转移性淋巴结平均通过时间显著低于良性淋巴结(p=0.04)。

诊断标准与关键数值

  • 多因素分析显示,最大径<10mm淋巴结的血流量与转移性淋巴结检测显著相关。
  • 血流量鉴别转移性与良性淋巴结的敏感度为73.3%,特异度为70.8%。

临床应用与阅片要点

  • 作者认为覆盖全颈的4D容积灌注CT可能有助于颈部淋巴结表征。
  • 作者认为值得将4D容积灌注CT纳入头颈部鳞状细胞癌的淋巴结分期。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to investigate the diagnostic performance of adaptive 4D volume perfusion CT covering the entire neck for detecting metastatic nodes in patients with head and neck squamous cell carcinoma.

SUBJECTS AND METHODS: Thirty patients with histologically confirmed disease were enrolled. The relation between perfusion parameters and nodal size was analyzed, and perfusion parameters were compared between metastatic and benign nodes. The diagnostic capability for detecting metastatic nodes was evaluated.

RESULTS: Significant inverse correlations with nodal size were found for blood flow (r = -0.40, p = 0.002), blood volume (r = -0.32, p = 0.02), and permeability surface product (r = -0.27, p = 0.04) of the metastatic nodes. All three parameters had significantly higher values in association with nodal maximum diameter < 10 mm compared with diameter ≥ 10 mm (blood flow, p = 0.004; blood volume, p = 0.01; permeability surface product, p = 0.02). Among the nodes with maximum diameter < 10 mm, blood flow of the metastatic nodes was significantly higher than that of the benign nodes (p = 0.02), whereas among the nodes ≥ 10 mm in diameter, the mean transit time of the metastatic nodes was significantly lower than that of the benign nodes (p = 0.04). In multivariate analysis, blood flow in nodes with maximum diameter < 10 mm had a significant association with the detection of metastatic nodes. The sensitivity and specificity of blood flow for differentiating metastatic from benign nodes were 73.3% and 70.8%.

CONCLUSION: Findings from 4D volume perfusion CT covering the entire neck may be informative for characterization of cervical nodes. It is worthwhile to include the examination in nodal staging of head and neck squamous cell carcinoma.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Matoba M, Tsuji H, Shimode Y, et al. Diagnostic Performance of Adaptive 4D Volume Perfusion CT for Detecting Metastatic Cervical Lymph Nodes in Head and Neck Squamous Cell Carcinoma. AJR Am J Roentgenol. 2018. PMID: 30240295. doi:10.2214/AJR.17.19241

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。