文献速递神经介入DSAMR

球囊辅助弹簧圈栓塞后置入支架治疗宽颈动脉瘤的再通率低:联合技术可在随访期间获得稳定且改善的结果

Low rates of recanalization for wide-necked aneurysms treated with stenting after balloon-assisted coiling: combination of techniques delivers stable and improved results during follow-up.
PubMed 文献 · Neuroradiology · 2018-09-05

回顾性分析87个未破裂宽颈动脉瘤(80例患者),在球囊辅助弹簧圈栓塞因弹簧圈脱出而最终置入支架。初始完全闭塞53个(60.9%)、近完全闭塞28个(32.2%);随访80个动脉瘤平均34.68±25.26个月,92.4%(74/80)稳定或进一步血栓形成,再通6例(7.5%,6/83)。作者认为该联合技术再通率低、远期造影结果改善。

要点

  • 球囊辅助弹簧圈栓塞后因弹簧圈脱出置入支架,随访再通率仅7.5%(6/83)。
  • 随访平均34.68±25.26个月,92.4%(74/80)动脉瘤稳定或进一步血栓形成。
  • 动脉瘤大小与结局无显著差异(p=0.641)。

核心结论

  • 作者认为,球囊辅助弹簧圈栓塞后置入支架治疗宽颈动脉瘤的再通率低,长期随访造影结果改善且稳定。

研究设计与样本

  • 回顾性研究,纳入80例患者的87个未破裂宽颈动脉瘤,均在球囊辅助弹簧圈栓塞术最终阶段因弹簧圈脱出而置入支架;由两名独立评估者判读治疗后及随访造影,分为「稳定」「进一步血栓形成」「再通」。

诊断标准与关键数值

  • 动脉瘤平均最大直径9.1±4.7 mm,纵横比1.20±0.47。
  • 初始完全闭塞53个(60.9%),近完全闭塞28个(32.2%)。
  • 随访80个动脉瘤(平均34.68±25.26个月),稳定或进一步血栓形成占92.4%(74/80)。
  • 再通6例(7.5%,6/83),其中4例再次治疗。
  • 动脉瘤大小与结局无显著差异(p=0.641)。

临床应用与阅片要点

  • 作者认为,球囊辅助弹簧圈栓塞后置入支架治疗宽颈动脉瘤可获得低再通率和改善的长期造影结果。
  • 随访造影判读采用「稳定」「进一步血栓形成」「再通」三类,再通者中4例再次治疗。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: In the treatment of wide-necked aneurysms, stenting may be required after balloon-assisted coiling (BAC) for reconstructing the lumen/flow of the parent artery in cases of coil herniation. The potential benefits and complications of both techniques remain unclear when used together. Our aim was to assess the safety and long-term angiographic outcomes of stenting after BAC.

METHODS: Retrospective review of 87 unruptured wide necked aneurysms (in 80 patients) treated with BAC and requiring stent placement at the final stage of the procedure due to coil prolapse. Aneurysm characteristics, technical issues, clinical records, and MR results were assessed. Post-treatment and follow-up angiograms were evaluated by two independent reviewers and categorized as "stable," "further thrombosis," or "recanalization."

RESULTS: The mean maximum diameter was 9.1 ± 4.7 mm and aspect ratio 1.20 ± 0.47. Complete and near-complete initial occlusion were observed in 53 (60.9%) and 28 (32.2%) of all treated aneurysms, respectively. Angiographic follow-up (80 aneurysms; mean, 34.68 ± 25.26 months) revealed stability and further thrombosis in 92.4% (74/80). Recanalization was observed in six cases (7.5%, 6/83), four of which were retreated. No significantly different outcomes were found in terms of aneurysm size (p = 0.641). Transient and reversible procedure-related complications occurred in eight (9.2%), minor permanent deficits in 2.3%, and major deficits, including death, in four cases (4.6%).

CONCLUSION: Our results suggest that treatment of wide-necked aneuryms with stent placement after BAC yields low recanalization rates and enhanced angiographic outcomes in long-term follow-up.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Velasco González A, Stracke P, Nordmeyer H, et al. Low rates of recanalization for wide-necked aneurysms treated with stenting after balloon-assisted coiling: combination of techniques delivers stable and improved results during follow-up. Neuroradiology. 2018. PMID: 30187084. doi:10.1007/s00234-018-2088-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。