文献速递神经CT

早期缺血性卒中「高密度动脉征」:基于模型重建与标准混合迭代重建算法的诊断价值比较

"Hyperdense artery sign" in early ischemic stroke: diagnostic value of model-based reconstruction approach in comparison with standard hybrid iterative reconstruction algorithm.
PubMed 文献 · Neuroradiology · 2018-09-08

本研究连续纳入56例疑似缺血性卒中患者,均行平扫CT且血管造影CT证实血管闭塞或随访CT出现缺血灶;两位读者随机分析iDose4(4 mm)与IMR(2 mm)重建图像。IMR重建下两位读者均能在55/56例中识别高密度血管征,而iDose仅识别12/56例;IMR图像质量评分更高、血栓密度更高、噪声指数更低、CNR与SNR更高。

要点

  • IMR重建识别高密度动脉征55/56例,iDose4仅12/56例。
  • IMR图像质量评分3.32 vs iDose4 2.53,血栓密度57.2 vs 46.7 HU。
  • IMR噪声指数5 vs iDose4 2,CNR 4.2 vs 2,SNR 16.8 vs 8.5。

核心结论

  • 基于模型的重建方法较标准混合迭代重建算法显著提高检测高密度动脉征的敏感度,并提供更高的SNR和CNR。

研究设计与样本

  • 连续纳入56例疑似缺血性卒中患者,均行平扫CT,且血管造影CT显示血管闭塞或随访CT出现缺血病灶。
  • 两位读者随机分析iDose4(4 mm)与IMR(2 mm)重建的平扫CT图像。
  • 平均CTDI为43 mGy,DLP为819.7 mGy cm,ED为1.72 mSv。

关键影像表现/征象

  • 高密度动脉征在IMR重建下两位读者均识别55/56例,iDose4重建下仅识别12/56例。
  • IMR图像质量平均评分3.32,iDose4为2.53。
  • IMR血栓密度57.2 HU,iDose4为46.7 HU。
  • IMR噪声指数5,iDose4为2;IMR的CNR 4.2、SNR 16.8,iDose4的CNR 2、SNR 8.5。

诊断标准与关键数值

  • 高密度动脉征报告为0:无;1:有;2:不确定。
  • 图像质量采用4分制评分:1:不可接受;4:高于平均水平。

临床应用与阅片要点

  • 采用基于模型迭代重建(IMR,2 mm)可提高高密度动脉征的检出,阅片时需结合重建算法与层厚判读。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Hyperdense artery sign is the earliest sign of ischemic stroke on non-enhanced computed tomography and it can be visible long before parenchymal changes. The aim of our study was to compare diagnostic value of model-based iterative reconstruction algorithm (IMR) with that of iterative reconstruction algorithm (iDose4) in identifying hyperdense artery sign.

METHODS: We selected 56 consecutive patients suspected for ischemic stroke, who underwent a NCCT and that demonstrated a vessel occlusion at angio-CT or developed ischemic lesion at follow-up CT. Two readers randomly analyzed images of NCCT reconstructed both with iDose4 (4 mm) and IMR (2 mm), reporting presence of hyperdense artery sign (0: no; 1: yes; 2: not sure). They rated image quality on a 4-point scale (1: unacceptable; 4: more than average) and recorded HU values of clot and of normal vessel and measured noise index, CNR and SNR.

RESULTS: Mean values of CTDI, DLP, and ED were respectively of 43 mGy, 819.7 mGy cm, and 1.72 mSv. By analyzing the IMR reconstruction, both readers were able to recognize hyperdense vessel sign in 55/56 patients, while only in 12/56 patients were identified with iDose. IMR obtained better rating of image quality (mean score for IMR 3.32 vs 2.53 for iDose), higher clot density (57.2 vs 46.7 HU), lower noise index (5 vs 2), higher CNR and SNR (respectively 4.2 vs 2 and 16.8 vs 8.5).

CONCLUSIONS: Model-based approach significantly increases sensitivity in detecting hyperdense artery sign, offering higher SNR and CNR in brain CT images in comparison with standard hybrid reconstruction algorithm.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Lombardi S, Riva L, Patassini M, et al. "Hyperdense artery sign" in early ischemic stroke: diagnostic value of model-based reconstruction approach in comparison with standard hybrid iterative reconstruction algorithm. Neuroradiology. 2018. PMID: 30196373. doi:10.1007/s00234-018-2092-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。