文献速递神经技术与安全CTMR

多模态体素分析统一平台用于评估放射治疗前后肿瘤灌注与扩散特征:在转移性脑癌中的验证

Unified platform for multimodal voxel-based analysis to evaluate tumour perfusion and diffusion characteristics before and after radiation treatment evaluated in metastatic brain cancer.
PubMed 文献 · Br J Radiol · 2019-02-26

本研究构建了基于体素的多模态统一分析平台,将灌注与扩散的溶质转运过程纳入同一框架,并在合成数据、数字参考对象及治疗前后接受容积DCE-CT、DCE-MRI和DWI-MRI扫描的患者中进行验证。结果显示CT与MR药代动力学参数间存在统计学显著相关,第7天Ktrans相关性峰值R=0.74,ADC与Ve最高中位相关出现在第3天(R=0.6),采用体素T10图较固定T10值相关性更强(R=0.575)。作者认为统一平台较既往报道显示不同模态间药代动力学参数更高相关性。

要点

  • 统一体素分析平台可自动计算每体素药代动力学参数,不依赖观察者判读。
  • CT与MR的Ktrans相关性在第7天达峰值(R=0.74,p≤0.0001)。
  • ADC与Ve最高中位相关在第3天(R=0.6,p<0.01),用体素T10图时DCE-MRI与DCE-CT相关最强(R=0.575,p<0.001)。

核心结论

  • 多参数转运建模的统一实现可提供更稳健、及时且不依赖观察者的数据分析,统一分析平台显示不同模态间药代动力学参数相关性高于既往报道。

研究设计与样本

  • 基于体素的多模态统一分析平台,先在合成Tofts模型数据和数字参考对象上测试,再在治疗前后接受容积DCE-CT、DCE-MRI和DWI-MRI扫描的患者中评估。

诊断标准与关键数值

  • 合成Tofts模型数据平均相对百分误差为1.07×10⁻⁷,数字参考对象为5.60×10⁻⁴;CT与MR的Ktrans体素-体素Pearson相关第7天达峰值R=0.74(p≤0.0001);ADC与Ve中位相关最高在第3天R=0.6(p<0.01);DCE-MRI采用体素T10图时与DCE-CT相关最强R=0.575(p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE:: Early changes in tumour behaviour following stereotactic radiosurgery) are potential biomarkers of response. To-date quantitative model-based measures of dynamic contrast-enhanced (DCE) and diffusion-weighted (DW) MRI parameters have shown widely variable findings, which may be attributable to variability in image acquisition, post-processing and analysis. Big data analytic approaches are needed for the automation of computationally intensive modelling calculations for every voxel, independent of observer interpretation.

METHODS:: This unified platform is a voxel-based, multimodality architecture that brings complimentary solute transport processes such as perfusion and diffusion into a common framework. The methodology was tested on synthetic data and digital reference objects and consequently evaluated in patients who underwent volumetric DCE-CT, DCE-MRI and DWI-MRI scans before and after treatment. Three-dimensional pharmacokinetic parameter maps from both modalities were compared as well as the correlation between apparent diffusion coefficient (ADC) values and the extravascular, extracellular volume (Ve). Comparison of histogram parameters was done via Bland-Altman analysis, as well as Student's t-test and Pearson's correlation using two-sided analysis.

RESULTS:: System testing on synthetic Tofts model data and digital reference objects recovered the ground truth parameters with mean relative percent error of 1.07 × 10-7 and 5.60 × 10-4 respectively. Direct voxel-to-voxel Pearson's analysis showed statistically significant correlations between CT and MR which peaked at Day 7 for Ktrans (R = 0.74, p <= 0.0001). Statistically significant correlations were also present between ADC and Ve derived from both DCE-MRI and DCE-CT with highest median correlations found at Day 3 between median ADC and Ve,MRI values (R = 0.6, p < 0.01) The strongest correlation to DCE-CT measurements was found with DCE-MRI analysis using voxelwise T10 maps (R = 0.575, p < 0.001) instead of assigning a fixed T10 value.

CONCLUSION:: The unified implementation of multiparametric transport modelling allowed for more robust and timely observer-independent data analytics. Utility of a common analysis platform has shown higher correlations between pharmacokinetic parameters obtained from different modalities than has previously been reported.

ADVANCES IN KNOWLEDGE:: Utility of a common analysis platform has shown statistically higher correlations between pharmacokinetic parameters obtained from different modalities than has previously been reported.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Coolens C, Driscoll B, Foltz W, et al. Unified platform for multimodal voxel-based analysis to evaluate tumour perfusion and diffusion characteristics before and after radiation treatment evaluated in metastatic brain cancer. Br J Radiol. 2019. PMID: 30235004. doi:10.1259/bjr.20170461

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。