高加速压缩感知飞行时间MR血管成像诊断颅内动脉狭窄的临床评估

Clinical Evaluation of Highly Accelerated Compressed Sensing Time-of-Flight MR Angiography for Intracranial Arterial Stenosis.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-09-13

本研究对22例颅内动脉狭窄患者行压缩感知TOF与并行成像TOF-MRA,压缩感知TOF扫描时间2分31秒、并行成像4分48秒;两者图像质量相当,压缩感知TOF诊断狭窄的置信度更高(P=.025),血管边缘锐度显著更高(P<.001),狭窄率无显著差异。

要点

  • 压缩感知TOF扫描时间2分31秒,较并行成像TOF的4分48秒明显缩短。
  • 压缩感知TOF图像质量与并行成像TOF相当,诊断动脉狭窄的置信度更高(P=.025)。
  • 压缩感知TOF颅内动脉边缘锐度显著高于并行成像TOF(P<.001),狭窄率无显著差异。

核心结论

  • 压缩感知TOF显著缩短扫描时间,并为颅内动脉狭窄的诊断提供足够的图像质量。

研究设计与样本

  • 对22例颅内动脉狭窄患者行压缩感知TOF和并行成像TOF-MRA检查。
  • 压缩感知TOF扫描时间2分31秒,并行成像TOF扫描时间4分48秒。
  • 压缩感知TOF重建分辨率0.4×0.4×0.4 mm3,并行成像TOF为0.4×0.4×0.6 mm3。

关键影像表现/征象

  • 压缩感知TOF图像质量与并行成像TOF相当,但诊断动脉狭窄的置信度更高(P=.025)。
  • 压缩感知TOF颅内动脉边缘锐度显著高于并行成像TOF(P<.001)。
  • 压缩感知TOF与并行成像TOF的管腔狭窄率无显著差异。

诊断标准与关键数值

  • 由2名对检查方法盲法的神经放射科医师独立对图像诊断质量和狭窄可见度进行评分,采用Wilcoxon符号秩检验比较。
  • 采用Cohen κ计算一致性,评估者间一致性为良好至优秀。
  • 血管边缘锐度和管腔狭窄率采用配对样本t检验比较。

临床应用与阅片要点

  • 压缩感知TOF可显著缩短扫描时间,同时为颅内动脉狭窄诊断提供足够图像质量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Time-of-flight MR angiography is the preferred imaging technique to assess intracranial arterial stenosis but is limited by a relatively long acquisition time. Compressed sensing provides an innovative approach in undersampling k-space to minimize the data-acquisition time. We aimed to evaluate the diagnostic accuracy of compressed sensing TOF for detecting intracranial arterial stenosis by comparison with conventional parallel imaging TOF-MRA.

MATERIALS AND METHODS: Compressed sensing TOF and parallel imaging TOF were performed in 22 patients with intracranial arterial stenosis. The MRA scan times were 2 minutes and 31 seconds and 4 minutes and 48 seconds for compressed sensing TOF and parallel imaging TOF, respectively. The reconstructed resolutions were 0.4 × 0.4 × 0.4 and 0.4 × 0.4 × 0.6 mm3 for compressed sensing TOF and parallel imaging TOF, respectively. The diagnostic quality of the images and visibility of the stenoses were independently ranked by 2 neuroradiologists blinded to the type of method and were compared using the Wilcoxon signed rank test. Concordance was calculated with the Cohen κ. Edge sharpness of the arteries and the luminal stenosis ratio were analyzed and compared using a paired-sample t test.

RESULTS: The interrater agreement was good to excellent. Compressed sensing TOF resulted in image quality comparable with that of parallel imaging TOF but boosted confidence in diagnosing arterial stenoses (P = .025). The edge sharpness of the intracranial arteries for compressed sensing TOF was significantly higher than that for parallel imaging TOF (P < .001). The luminal stenosis ratio on compressed sensing TOF showed no significant difference compared with that on parallel imaging TOF.

CONCLUSIONS: Compressed sensing TOF both remarkably reduced the scan time and provided adequate image quality for the diagnosis of intracranial arterial stenosis.