血管壁MR成像在颅内动脉瘤支架辅助弹簧圈栓塞术后随访中的应用价值
单中心回顾性研究纳入47例颅内动脉瘤支架辅助弹簧圈栓塞术后患者,比较血管壁MRI与3D TOF-MRA评估支架载瘤动脉通畅性的价值,以DSA为参考。血管壁MRI显示支架动脉与正常动脉信号强度无显著差异(P = .133),支架载瘤动脉可视化评分显著优于TOF-MRA(P < .001),阳性预测值达100%,与DSA一致率100%(κ = 1);TOF-MRA阳性预测值仅11%(95% CI, 9%-12%),一致率28%(κ = 0.038)。
要点
- 血管壁MRI评估支架载瘤动脉通畅性阳性预测值100%,与DSA一致率100%(κ = 1)。
- TOF-MRA阳性预测值仅11%(95% CI, 9%-12%),与DSA一致率28%(κ = 0.038)。
- 血管壁MRI支架载瘤动脉可视化评分显著优于TOF-MRA(P < .001)。
核心结论
- 血管壁MRI可能有助于评估颅内动脉瘤支架辅助弹簧圈栓塞术后支架动脉的通畅性。
研究设计与样本
- 单中心回顾性病历回顾研究,纳入47例在2016年3月至2018年1月间接受支架辅助弹簧圈栓塞术后行3D TOF-MRA、血管壁MRI和DSA检查的患者。
- 以DSA为参考标准,比较TOF-MRA与血管壁MRI评估支架载瘤动脉通畅性的诊断准确率和一致率。
关键影像表现/征象
- 血管壁MRI上支架动脉与对侧正常动脉的平均信号强度无显著差异(P = .133)。
- 血管壁MRI上支架载瘤动脉可视化平均评分显著优于TOF-MRA图像(P < .001)。
诊断标准与关键数值
- 血管壁MRI评估支架载瘤动脉的阳性预测值为100%,似然比27.36(P < .001),与DSA一致率100%(κ = 1)。
- TOF-MRA评估支架载瘤动脉的阳性预测值为11%(95% CI, 9%-12%),似然比2.98(P = .225),与DSA一致率28%(κ = 0.038)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Follow-up with MRA for intracranial aneurysms after stent-assisted coiling is complicated by imaging artifacts. We evaluated the usefulness of an alternative method: vessel wall MR imaging.
MATERIALS AND METHODS: We conducted a single-center, retrospective review of medical records of 47 patients who underwent 3D TOF-MRA, vessel wall MRI, and DSA after stent-assisted coiling between March 2016 and January 2018. We evaluated the mean value of the signal intensity in the stented artery and the contralateral normal artery on vessel wall MRI. The quality of visualization was further compared between TOF-MRA and vessel wall MRI. Furthermore, we evaluated the diagnostic accuracy and concordance rate of TOF-MRA and vessel wall MRI for assessing the patency of the stented parent artery. DSA was used as a reference test.
RESULTS: The mean signal intensities of the stented and normal arteries on vessel wall MRI were not significantly different (P = .133). The mean scores for the visualization of the stented parent artery on vessel wall MRI were significantly superior to those of TOF-MRA images (P < .001). Vessel wall MRI reached an excellent positive predictive value (100%). However, TOF-MRA had a poor positive predictive value (11%; 95% CI, 9%-12%). The likelihood ratios of vessel wall MRI and TOF-MRA were 27.36 (P < .001) and 2.98 (P = .225), respectively. The concordance rate of vessel wall MRI and TOF-MRA with DSA for evaluating the state of the stented artery was 100% (κ = 1) and 28% (κ = 0.038), respectively.
CONCLUSIONS: Vessel wall MRI may be useful in evaluating the patency of stented arteries after stent-assisted coil embolization for intracranial aneurysms.
引用
- Kim S, Kang M, Kim DW, et al. Usefulness of Vessel Wall MR Imaging for Follow-Up after Stent-Assisted Coil Embolization of Intracranial Aneurysms. AJNR Am J Neuroradiol. 2018. PMID: 30262640. doi:10.3174/ajnr.A5824
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。