双能CT血管成像在颅内动脉瘤治疗术后患者中的价值
前瞻性纳入35例动脉瘤修复术后患者行双源双能CT血管成像,分析40个动脉瘤(弹簧圈栓塞23个、手术夹闭17个)。夹闭动脉瘤虚拟单能图像较混合图像显著减少伪影,95 keV为兼顾邻近血管对比的最佳折中;弹簧圈栓塞动脉瘤伪影无显著减少。
要点
- 夹闭动脉瘤在95 keV虚拟单能图像上伪影最少且邻近血管对比最佳。
- 弹簧圈栓塞动脉瘤在虚拟单能图像上伪影无显著减少。
- 双能CT血管成像减伪影效果因治疗方式而异,阅片需分别对待。
核心结论
- 双源双能CT血管成像的虚拟单能图像有助于减少夹闭动脉瘤的伪影,95 keV时邻近血管显示最佳,但对弹簧圈栓塞动脉瘤无帮助。
研究设计与样本
- 前瞻性研究,35例动脉瘤修复术后患者行双源双能CT血管成像(Somatom Force,Siemens Medical Solutions,Forchheim,Germany),分析40个动脉瘤(弹簧圈栓塞23个、手术夹闭17个),混合图像与75、95、115 keV虚拟单能图像比较。
诊断标准与关键数值
- 定量评估兴趣区平均衰减值和标准差,定性评估伪影严重程度评分和对比血管评分,由两名独立盲法阅片者完成。
临床应用与阅片要点
- 夹闭动脉瘤可参考95 keV虚拟单能图像以减少伪影并保持邻近血管对比;弹簧圈栓塞动脉瘤在虚拟单能图像上未见显著减伪影效果。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the ability of dual-energy CT angiography (DECTA) in metal artifact reduction in patients with treated intracranial aneurysms by comparing DECTA-based virtual monoenergetic extrapolations (VMEs) and mixed images (MI).
METHODS: Thirty-five patients underwent prospectively a dual-source DECTA (Somatom Force, Siemens Medical Solutions, Forchheim, Germany) after aneurysm repair. A total number of 40 aneurysms (23 treated by coil embolization and 17 treated by surgical clipping) were analyzed. Mixed images (equivalent to a conventional single-energy CT angiography) were compared to VMEs at 75, 95, and 115 keV. Artifact severity was assessed quantitatively by measuring the mean attenuation value and standard deviation within regions of interest placed in the most hypodense coil or clip artifact area. Artifact severity score and contrast vessel score were also assessed qualitatively by two independent blinded readers.
RESULTS: In those aneurysms treated by surgical clipping, quantitative and qualitative analyses showed significant reduction of artifacts on VMEs compared to MI with the best compromise being obtained at 95 keV in order to keep an optimal vessel contrast in the adjacent vessel. In those aneurysms treated by coil embolization, there was no significant reduction of artifacts both on quantitative and qualitative analyses.
CONCLUSION: Dual-source DECTA was helpful in order to reduce clip artifacts on VMEs with the optimal adjacent vessel visualization obtained at 95 keV, whereas this technique was not helpful in aneurysms treated by coiling.
引用
- Mocanu I, Van Wettere M, Absil J, et al. Value of dual-energy CT angiography in patients with treated intracranial aneurysms. Neuroradiology. 2018. PMID: 30219936. doi:10.1007/s00234-018-2090-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。