上呼吸消化道高级别异型增生、原位癌及鳞状细胞癌的检出:窄带成像最佳使用与解读建议
荷兰格罗宁根大学医学中心回顾性研究纳入370例上呼吸消化道硬性内镜检查患者,评估窄带成像(NBI)诊断潜力及常见误判原因。NBI检出浸润癌、原位癌或高级别异型增生的敏感度92%、特异度68%、准确率77%;仅依据Ni分型V型判读时多观察者分析准确率65%,结合病变特异性临床特征后74%。作者建议充分放大并避免出血、模糊和光照不足以优化NBI图像质量。
要点
- NBI检出浸润癌、原位癌或高级别异型增生的敏感度92%、特异度68%、准确率77%。
- 仅依据Ni分型V型判读准确率65%,结合病变特异性临床特征后74%。
- 白斑、乳头状瘤及放疗后黏膜病变是导致误判的常见病变。
核心结论
- NBI是检出上呼吸消化道恶性肿瘤相对可靠的筛查方法,但仅依据Ni分型判读不够充分。
研究设计与样本
- 回顾性研究,荷兰格罗宁根大学医学中心三级转诊医院,370例上呼吸消化道硬性内镜检查患者,2名观察者评估全部病变,12名观察者评估100例病变子集,均提供白光成像和NBI。
关键影像表现/征象
- 导致误判的病变为白斑、乳头状瘤及放疗后黏膜病变。
- 185张照片因模糊(36%)、出血(6%)、放大不足(15%)和/或光照不足(17%)被评为质量欠佳。
诊断标准与关键数值
- NBI检出浸润癌、原位癌或高级别异型增生的敏感度92%、特异度68%、阳性预测值61%、阴性预测值94%、准确率77%。
- 多观察者分析中,严格依据Ni分型V型判读的敏感度76%、特异度58%、阳性预测值53%、阴性预测值83%、准确率65%。
- 多观察者分析中,结合病变特异性临床特征判读的敏感度83%、特异度68%、阳性预测值64%、阴性预测值85%、准确率74%。
临床应用与阅片要点
- 作者建议充分放大并避免出血、模糊和光照不足,以优化NBI图像质量。
- 作者认为仅依据Ni分型判读不够充分,评估时还应结合病变特异性临床特征。
- 白斑、乳头状瘤及放疗后黏膜病变判读时易出现误判。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The primary goal was to study the diagnostic potential of narrow-band imaging (NBI), and the secondary goal was to evaluate the most common mistakes when using and interpreting NBI.
DESIGN: Retrospective study.
SETTING: University Medical Center Groningen, tertiary referral hospital, the Netherlands.
PARTICIPANTS: Three hundred and seventy patients who underwent rigid endoscopy of the upper aerodigestive tract. Two observers assessed all lesions. Twelve observers assessed a selection of 100 lesions. All observers were provided with both white light imaging and NBI.
MAIN OUTCOME MEASURES: Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy and reasons for insufficient photograph quality.
RESULTS: When using NBI, the sensitivity, specificity, PPV, NPV and accuracy for detecting invasive carcinoma, carcinoma in situ or high-grade dysplasia were 92%, 68%, 61%, 94% and 77%, respectively. In multiple-observer analysis, values were 76%, 58%, 53%, 83% and 65% with the evaluation strictly based on type V patterns of Ni's classification, vs 83%, 68%, 64%, 85% and 74% when evaluation was also based on lesion-specific clinical characteristics. Lesions that caused misinterpretations were leukoplakia, papillomas and mucosal lesions after irradiation. In total, 185 photographs were assessed to be of suboptimal quality due to blurring (36%), bleeding (6%), insufficient zooming (15%) and/or insufficient lighting (17%).
CONCLUSION: NBI is a relatively reliable screening method for detecting malignancy. Evaluation based on Ni's classification alone is not sufficient. To optimise NBI photograph quality, we recommend sufficient zooming and prevention of bleeding, blurring and inadequate lighting.
引用
- Zwakenberg MA, Dikkers FG, Wedman J, et al. Detection of high-grade dysplasia, carcinoma in situ and squamous cell carcinoma in the upper aerodigestive tract: Recommendations for optimal use and interpretation of narrow-band imaging. Clin Otolaryngol. 2018. PMID: 30222908. doi:10.1111/coa.13229
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。