文献速递技术与安全PETCT

基于体重的方案在全身FDG PET/CT中显著降低辐射剂量且不影响图像质量:大型队列研究发现

Body Weight-Based Protocols During Whole Body FDG PET/CT Significantly Reduces Radiation Dose without Compromising Image Quality:Findings in a Large Cohort Study.
PubMed 文献 · Acad Radiol · 2018-08-23

结果显示基于体重的方案在保持图像质量的同时显著降低辐射剂量,但体重方案IIB组患者体重与其他组存在显著差异。

要点

  • 按体重分级设置管电流可在全身FDG PET/CT中显著降低有效剂量。
  • 各级体重方案与常规方案相比对比噪声比无显著差异,视觉分级偏好体重方案。
  • 体重方案IIB组患者体重与其他组有显著差异,可能影响组间可比性。

核心结论

  • 采用基于患者体重的个体化方案可在全身18F-FDG PET/CT中显著降低辐射剂量,且不损害图像质量。

诊断标准与关键数值

  • 体重方案II分四档:A档(≤60 kg)35 mAs,B档(61-80 kg)50 mAs,C档(81-100 kg)65 mAs,D档(>101 kg)100 mAs;图像质量采用定量对比噪声比和定性视觉分级特征评估。

临床应用与阅片要点

  • 在全身FDG PET/CT中可按患者体重分档设置管电流以降低辐射剂量,同时需注意体重方案IIB组患者体重与其他组存在显著差异。

局限性

  • 患者人口学特征在各方案间无显著差异,但体重方案IIB组患者体重存在显著差异(p < 0.009)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To investigate radiation dose reduction during whole body fluorodeoxyglucose (18F-FDG) positron emission tomographic (PET)/computed tomography (CT) by employing weight-based protocols.

MATERIALS AND METHODS: One thousand and twenty-eight patients were referred for 18F-FDG PET/CT study with one of two protocols: conventional protocol I; 120 kVp, 120 mAs, 0.5 second rotation time, pitch 0.8 mm/rot across all body weights; four-tier body weight protocol II all used 140 kVp, 0.75 seconds rotation time and pitch 0.8 mm/rot: Protocol A (≤60 kg): 35 mAs, Protocol B (61-80 kg): 50 mAs, Protocol C (81-100 kg): 65 mAs, and Protocol D: (>101 kg): 100 mAs. All protocols employed tube current modulation. Quantitative and qualitative image visual grading characteristics assessed image quality.

RESULTS: Patient demographics demonstrated no significant difference between each protocol except for patient weight in weight protocol IIB (p < 0.009). Mean effective dose in all protocols were significantly lower in Protocol B compared to A (p < 0.009). Contrast-to-noise ratio demonstrated no differences between each protocol (p < 0.21) except for weight protocol in protocol IIA (<60 kg, p = 0.035) with the visual grading characteristics demonstrating preference over protocol II compared to I.

CONCLUSION: Significant reduction in radiation dose can be achieved using patient-specific body weight-based protocols during whole-body 18F-FDG PET/CT without compromising image quality when employing weight-based protocols.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Saade C, Ammous A, Abi-Ghanem AS, et al. Body Weight-Based Protocols During Whole Body FDG PET/CT Significantly Reduces Radiation Dose without Compromising Image Quality:Findings in a Large Cohort Study. Acad Radiol. 2018. PMID: 30145204. doi:10.1016/j.acra.2018.07.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。