文献速递骨肌MR

高浓度碘对比剂用于T1加权直接磁共振关节造影

High-concentration iodinated contrast media for T1-weighted direct magnetic resonance arthrography.
PubMed 文献 · Clin Radiol · 2018-08-09

本研究通过体外1.5 T MRI实验量化碘对比剂的T1W信号表达,并在15只正常兔中比较碘普罗胺(370 mg碘/ml)与碘普罗胺稀释钆对比剂混合物的体内表现;体外碘普罗胺最高SNR为Gd-DOTA的45.9%,体内关节内及关节外碘普罗胺和混合物的SNR均显著高于肌肉(p<0.01),作者认为高浓度碘对比剂可为T1W直接MRI关节造影提供良好图像质量并可能作为特定临床情况下的替代选择。

要点

  • 体外实验中碘普罗胺浓度越高SNR越高,最高SNR为Gd-DOTA的45.9%。
  • 兔体内关节内及关节外碘普罗胺和混合物SNR均显著高于肌肉(p<0.01)。
  • 作者认为高浓度碘对比剂可能作为T1W直接MRI关节造影的替代选择。

核心结论

  • 高浓度碘对比剂可为T1W直接MRI关节造影提供良好图像质量,并可能作为特定临床情况下的替代选择。

研究设计与样本

  • 体外研究在1.5 T MRI系统上使用Gd-DOTA、碘普罗胺与Gd-DOTA混合物及单用碘普罗胺进行;体内研究使用15只正常兔比较碘普罗胺(370 mg碘/ml)与碘普罗胺稀释Gd-DOTA混合物,其中9只兔行关节外给药以模拟对比剂渗漏,扫描序列为FS T1W和轴位IDEAL T1W。

关键影像表现/征象

  • 体外实验中碘普罗胺浓度越高SNR越高,碘普罗胺最高SNR为Gd-DOTA的45.9%。
  • 体内研究中所有兔的碘普罗胺和混合物均被良好识别。
  • FS T1W图像上关节内和关节外碘普罗胺及混合物的SNR均显著高于肌肉SNR(均p<0.01)。
  • IDEAL图像上关节内和关节外碘普罗胺及混合物的SNR均显著高于肌肉SNR(均p<0.01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To quantify in vitro the T1-weighted (T1W) expression of iodinated contrast media (CM), and to compare the in vivo performances of iodinated CM and gadolinium-based CM for T1W direct magnetic resonance imaging (MRI) arthrography.

MATERIALS AND METHODS: An in vitro study on a 1.5 T MRI system was performed using Gd-DOTA, a mixture of iopromide and Gd-DOTA, and iopromide alone. The fat-suppressed (FS) T1W signal intensities were measured and analysed. In an in vivo study, 15 normal rabbits were used to compare the expression of iopromide (370 mg iodine/ml), and the mixture of iopromide and diluted Gd-DOTA. In nine of the 15 rabbits, extra-articular administrations of CM were performed to mimic the situation of CM leak. The rabbits were scanned on a 1.5 T MRI system, and the FS T1W sequence and an axial iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) T1W sequence were acquired. Signal intensities were measured and signal-to-noise ratios (SNR) were analysed.

RESULTS: In the in vitro study, a higher SNR was noted in a higher concentration of iopromide, and the highest SNR of iopromide was 45.9% of that of Gd-DOTA. In the in vivo study, the iopromide and the mixture were well identified in all rabbits. The SNRs of the intra-articular and extra-articular iopromide and the mixture were significantly higher than the SNR of the muscles in the FS T1W images (all, p<0.01) and the IDEAL images (all, p<0.01).

CONCLUSIONS: A high-concentration iodinated CM can provide good imaging quality for T1W direct MRI arthrography, and may be an alternative option in certain clinical situations.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Huang YF, Hsieh TJ, Chen YJ, et al. High-concentration iodinated contrast media for T1-weighted direct magnetic resonance arthrography. Clin Radiol. 2018. PMID: 30100345. doi:10.1016/j.crad.2018.07.100

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。