文献速递腹部泌尿生殖CT

基于光子计数CT的肾结石检测与成分表征

Detection and Characterization of Renal Stones by Using Photon-Counting-based CT.
PubMed 文献 · Radiology · 2018-08-07

研究纳入30例已知肾结石患者,在同一辐射剂量下先后行双能量CT与研究用光子计数探测器CT扫描,由两名放射科医师检测结石并用商业双能量CT分析软件区分尿酸与非尿酸结石。共检出160枚结石(91枚≤3mm);光子计数CT对全部结石的检出优势比为1.29(95%CI 0.48, 3.45),结石分割与表征成功率70.0%(112/160) vs 双能量CT 54.4%(87/160),≤3mm结石光子计数CT成功45枚 vs 双能量CT 25枚(P=0.002)。结论认为光子计数CT检出肾结石与双能量CT相似,对小结石的表征能力更优。

要点

  • 光子计数CT检出全部肾结石的优势比1.29(95%CI 0.48, 3.45),与双能量CT相似。
  • 结石分割与表征成功率光子计数CT 70.0%(112/160) vs 双能量CT 54.4%(87/160)。
  • ≤3mm结石表征成功光子计数CT 45枚 vs 双能量CT 25枚(P=0.002),光子计数CT更优。

核心结论

  • 光子计数探测器CT检出肾结石与双能量CT相似,对小结石的表征能力优于双能量CT。

研究设计与样本

  • 研究纳入30例已知肾结石患者(中位年龄61岁,10例女性),先行临床双能量CT结石表征扫描,再行研究用光子计数探测器CT扫描,两者辐射剂量相同(以容积CT剂量指数表示);由两名放射科医师检测结石,并用商业双能量CT分析软件将结石表征为尿酸或非尿酸。

诊断标准与关键数值

  • 共检出160枚肾结石,其中91枚轴向长度≤3mm。
  • 与双能量CT 1mm层厚常规图像相比,光子计数CT检出全部结石的优势比为1.29(95%CI 0.48, 3.45)。
  • 结石分割与表征成功率:光子计数CT 70.0%(112/160) vs 双能量CT 54.4%(87/160)。
  • ≤3mm结石表征成功:光子计数CT 45枚 vs 双能量CT 25枚(P=0.002)。
  • 两扫描仪对全部大小结石的结石表征一致性为中等(k=0.65)。

临床应用与阅片要点

  • 光子计数CT检出肾结石与双能量CT相似,可用于肾结石检测。
  • 对≤3mm小结石,光子计数CT的分割与尿酸/非尿酸表征成功率高于双能量CT。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To compare a research photon-counting-detector (PCD) CT scanner to a dual-source, dual-energy CT scanner for the detection and characterization of renal stones in human participants with known stones. Materials and Methods Thirty study participants (median age, 61 years; 10 women) underwent a clinical renal stone characterization scan by using dual-energy CT and a subsequent research PCD CT scan by using the same radiation dose (as represented by volumetric CT dose index). Two radiologists were tasked with detection of stones, which were later characterized as uric acid or non-uric acid by using a commercial dual-energy CT analysis package. Stone size and contrast-to-noise ratio were additionally calculated. McNemar odds ratios and Cohen k were calculated separately for all stones and small stones (≤3 mm). Results One-hundred sixty renal stones (91 stones that were ≤ 3 mm in axial length) were visually detected. Compared with 1-mm-thick routine images from dual-energy CT, the odds of detecting a stone at PCD CT were 1.29 (95% confidence interval: 0.48, 3.45) for all stones. Stone segmentation and characterization were successful at PCD CT in 70.0% (112 of 160) of stones versus 54.4% (87 of 160) at dual-energy CT, and was superior for stones 3 mm or smaller at PCD CT (45 vs 25 stones, respectively; P = .002). Stone characterization agreement between scanners for stones of all sizes was substantial (k = 0.65). Conclusion Photon-counting-detector CT is similar to dual-energy CT for helping to detect renal stones and is better able to help characterize small renal stones. © RSNA, 2018.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Marcus RP, Fletcher JG, Ferrero A, et al. Detection and Characterization of Renal Stones by Using Photon-Counting-based CT. Radiology. 2018. PMID: 30084728. doi:10.1148/radiol.2018180126

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。