文献速递介入腹部DSA

大孔径放射学插入胃造瘘管类型间结局与相关并发症的回顾性比较

Retrospective comparison of outcomes and associated complications between large bore radiologically inserted gastrostomy tube types.
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

该回顾性研究利用介入放射学数据库与电子病历,比较了1477例患者中球囊保留(BR)、环保留(LR)和拉出型(PT)大孔径放射学插入胃造瘘装置的30天结局与并发症。LR导管总并发症率1.6%,显著低于BR导管的5.7%(P=0.01),LR与PT之间、BR与PT之间无显著差异。作者认为三类装置均安全,初次置管时大孔径LR导管可能优于BR装置。

要点

  • LR导管总并发症率1.6%,显著低于BR导管的5.7%(P=0.01)。
  • LR与PT之间、BR与PT之间并发症数量无显著差异。
  • 初次置管时大孔径LR导管可能优于BR装置(作者结论)。

核心结论

  • 使用BR、LR和PT装置进行RIG是安全的,并发症发生率低;与BR导管相比,初次插入LR胃造瘘管与30天内总并发症显著更少相关,因此对于初始置管,大孔径LR导管可能优于BR装置。

研究设计与样本

  • 回顾性研究,纳入2005年1月1日至2016年12月31日期间接受RIG的1477例患者,使用专用介入放射学数据库和电子病历收集数据,比较BR、LR和PT装置间的并发症率。

诊断标准与关键数值

  • BR导管总并发症率5.7%(主要并发症25例[3.3%],次要并发症18例[2.4%])。
  • PT导管总并发症率3.7%(主要并发症8例[2.0%],次要并发症7例[1.7%])。
  • LR导管总并发症率1.6%(主要并发症4例[1.4%],次要并发症1例[0.8%])。
  • 与BR导管相比,LR导管总并发症显著更少(P=0.01),但次要并发症无显著差异(P=0.052)。
  • LR与PT之间、BR与PT之间并发症数量无显著差异。

临床应用与阅片要点

  • 作者认为,对于初始置管,大孔径LR导管可能优于BR装置。
  • 使用BR、LR和PT装置进行RIG是安全的,并发症发生率低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Multiple approaches to radiologically inserted gastrostomy (RIG) exist. The goal of this study was to compare 30-day outcomes and associated complications between large bore balloon-retained (BR), loop-retained (LR), and pull-type (PT) RIG devices.

METHODS: Data on 1477 patients who underwent RIG between January 1, 2005 and December 31, 2016 were collected retrospectively using a dedicated interventional radiology database and electronic medical record. Statistical analysis was performed to compare complication rates between BR, LR, and PT devices.

RESULTS: Ninety-eight percent (1477/1507) of the procedures were successfully performed. A total of 752 BR, 323 LR, and 402 PT gastrostomy tubes were placed. The overall complication rate for BR catheters was 5.7% (25 major [3.3%] and 18 minor [2.4%]). The overall complication rate for PT catheters was 3.7% (8 major [2.0%] and 7 minor [1.7%]). The overall complication rate for LR catheters was 1.6% (4 major [1.4%] and 1 minor [0.8%]). Compared to BR catheters, LR catheters had significantly fewer total complications (P = 0.01) but not minor complications (P = 0.052). There were no significant differences in the number of complications between LR and PT catheters or between BR and PT catheters.

CONCLUSIONS: Use of BR, LR, and PT devices for RIG is safe with a low incidence of complications. Compared to BR catheters, primary insertion of a LR gastrostomy was associated with significantly fewer overall complications within the first 30 days. Therefore, for initial tube placement, large bore LR catheters may be preferred over BR devices.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Tischfield DJ, Nadolski GJ, Hunt SJ, et al. Retrospective comparison of outcomes and associated complications between large bore radiologically inserted gastrostomy tube types. Abdom Radiol (NY). 2019. PMID: 30073401. doi:10.1007/s00261-018-1717-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。