文献速递儿科影像腹部MR

锥形超短回波时间(UTE)MRI在儿童急性阑尾炎评估中的应用

Conical ultrashort echo time (UTE) MRI in the evaluation of pediatric acute appendicitis.
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

回顾性分析84例疑似阑尾炎患儿,比较自由呼吸锥形UTE、屏气3D SPGR和自由呼吸高分辨率3D SPGR三种增强序列的图像质量、解剖 delineation和诊断信心。UTE的感知信噪比和伪影少于两种SPGR序列,但对比度低于两者;直接配对比较中读片者显著更偏好UTE。

要点

  • 自由呼吸锥形UTE序列在感知信噪比和伪影控制上优于屏气及自由呼吸3D SPGR序列。
  • UTE的对比度显著低于屏气3D SPGR和自由呼吸高分辨率3D SPGR。
  • 读片者直接配对比较中显著更偏好UTE的整体图像质量。

核心结论

  • 在疑似阑尾炎评估中,自由呼吸锥形UTE MRI在所评估指标上优于自由呼吸高分辨率3D SPGR;与屏气3D SPGR相比,UTE的感知信噪比更高、伪影更少。

研究设计与样本

  • 回顾性研究,纳入84例因疑似阑尾炎行MRI的儿童患者,比较自由呼吸锥形UTE、屏气三维 spoiled gradient echo(BH-SPGR)和自由呼吸高分辨率三维SPGR(FB-SPGR)三种增强序列;两名放射科医师盲法独立评估。

诊断标准与关键数值

  • 图像质量采用四点量表,解剖 delineation采用四点量表,诊断信心采用五点量表,整体图像质量直接配对比较采用-3至+3量表;UTE感知信噪比均值3.6,BH-SPGR均值3.4,FB-SPGR均值3.1;UTE伪影均值3.4,BH-SPGR均值3.2,FB-SPGR均值2.7;对比度BH-SPGR均值3.6、FB-SPGR均值3.4、UTE均值3.2。

临床应用与阅片要点

  • 作者结论认为,在疑似阑尾炎评估中自由呼吸锥形UTE MRI在所评估指标上优于FB-SPGR;与BH-SPGR相比,UTE的感知信噪比更高、伪影更少。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Magnetic resonance imaging (MRI) sequences with conical k-space trajectories are able to decrease motion artifacts while achieving ultrashort echo times (UTE). We assessed the performance of free-breathing conical UTE MRI in the evaluation of the pediatric pelvis for suspected appendicitis.

METHODS: Our retrospective review of 84 pediatric patients who underwent MRI for suspected appendicitis compared three contrast-enhanced sequences: free-breathing conical UTE, breath-hold three-dimensional (3D) spoiled gradient echo (BH-SPGR), and free-breathing high-resolution 3D SPGR (FB-SPGR). Two radiologists performed blinded and independent evaluations of each sequence for image quality (four point scale), anatomic delineation (four point scale), and diagnostic confidence (five point scale). Subsequently, the three sequences were directly compared for overall image quality (- 3 to + 3 scale). Scores were compared using Kruskal-Wallis and Wilcoxon signed-rank tests.

RESULTS: UTE demonstrated significantly better perceived signal-to-noise ratio (SNR) and fewer artifacts than BH-SPGR and FB-SPGR (means of 3.6 and 3.4, 3.4 and 3.2, 3.1 and 2.7, respectively; p < 0.0006). BH-SPGR and FB-SPGR demonstrated significantly better contrast than UTE (means of 3.6, 3.4, and 3.2, respectively; p < 0.03). In the remaining categories, UTE performed significantly better than FB-SPGR (p < 0.00001), while there was no statistical difference between UTE and BH-SPGR. Direct paired comparisons of overall image quality demonstrated the readers significantly preferred UTE over both BH-SPGR (mean + 0.5, p < 0.00001) and FB-SPGR (mean + 1.2, p < 0.00001).

CONCLUSIONS: In the evaluation of suspected appendicitis, free-breathing conical UTE MRI performed better in the assessed metrics than FB-SPGR. When compared to BH-SPGR, UTE demonstrated superior perceived SNR and fewer artifacts.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Roh AT, Xiao Z, Cheng JY, et al. Conical ultrashort echo time (UTE) MRI in the evaluation of pediatric acute appendicitis. Abdom Radiol (NY). 2019. PMID: 30066168. doi:10.1007/s00261-018-1705-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。