文献速递骨肌儿科影像US

新手操作者使用二维与三维超声评估婴儿髋关节发育不良的可靠性

Reliability of 2D and 3D ultrasound for infant hip dysplasia in the hands of novice users.
PubMed 文献 · Eur Radiol · 2018-08-29

本研究纳入30例疑似发育性髋关节发育不良(DDH)婴儿,比较新手与专家操作者行二维超声(2DUS)和三维超声(3DUS)的组内与组间可靠性。2DUS组间可靠性差(ICC=0.10/0.04),3DUS组间可靠性中至高(ICC=0.73-0.83/0.55);新手使用3DUS正确分类57/58(98%)髋关节。结论认为新手操作3DUS的可靠性和准确性接近专家。

要点

  • 2DUS组间可靠性差:α角ICC=0.10,髋臼覆盖率ICC=0.04。
  • 3DUS组间可靠性中至高:α角ICC=0.73-0.83,髋臼覆盖率ICC=0.55。
  • 新手使用3DUS正确分类57/58(98%)婴儿髋关节。

核心结论

  • 新手操作者使用3DUS评估DDH的可靠性和准确性接近专家超声医师;新手使用2DUS的可靠性和准确性差。

研究设计与样本

  • 前瞻性纳入30例疑似DDH婴儿(平均年龄10.8周),新手(1.5小时培训)与专家(5-15年经验)分别行2DUS和3DUS,每名操作者采集两幅2DUS静态图像和两幅3DUS扫掠图像;以放射科医师审阅专家2DUS作为金标准诊断(正常、临界或发育不良)。

诊断标准与关键数值

  • 图像质量采用5分制评估(是/否:完整股骨头、完整髋臼顶、水平髂骨翼、坐骨、无运动/伪影):2DUS新手2.7±1.2 vs 专家4.9±0.3(p=0.04),3DUS新手4.2±1.0 vs 专家4.9±0.3(p=0.99)。2DUS组间可靠性差:α角ICC=0.10,髋臼覆盖率ICC=0.04;3DUS组间可靠性中至高:α角ICC=0.73-0.83,髋臼覆盖率ICC=0.55。3DUS组内可靠性和诊断准确性高于2DUS。

临床应用与阅片要点

  • 新手使用3DUS可正确分类57/58(98%)婴儿髋关节,提示3DUS可能使新手操作者可靠地评估DDH。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Developmental dysplasia of the hip (DDH) diagnosis by two-dimensional ultrasound (2DUS) can have poor inter-rater reliability. 3D ultrasound (3DUS) may be more reliably performed, particularly by novice users. We compared intra- and inter-rater reliability between expert and novice operators performing 2DUS and 3DUS for DDH.

MATERIALS AND METHODS: Infants with suspected DDH were assessed with 2DUS and 3DUS. Novice operators had 1.5 h of training and Experts had 5-15 years' experience. Images included two 2DUS static and two 3DUS sweep images per operator. Image quality was assessed by 5-point system (yes/no: full femoral head; full acetabular roof; horizontal iliac wing; os ischium; absent motion/artifact). 2DUS indices (alpha angle, coverage) were measured centrally by a blinded reader with 2 years DDH US experience. 3DUS was post-processed by semi-automated custom software generating acetabular surface models, indices and estimated probability of DDH. Gold-standard diagnosis of each hip as normal, borderline or dysplastic was based on radiologist review of expert 2DUS.

RESULTS: Thirty infants, mean age 10.8 weeks were enrolled. Quality scores were 2.7±1.2 Novice versus 4.9±0.3 Expert for 2DUS (p = 0.04), and 4.2±1.0 Novice versus 4.9±0.3 Expert for 3DUS (p = 0.99). Inter-rater reliability was poor for 2DUS (ICC=0.10 for alpha angle, 0.04 for acetabular coverage) and moderate to high for 3DUS (ICC=0.73-0.83 for alpha angle, 0.55 for acetabular coverage). Intra-rater reliability and diagnostic accuracy was higher for 3DUS than 2DUS.

CONCLUSION: Novice operators can perform 3DUS for DDH with reliability and accuracy approaching expert sonographers. Novices perform 2DUS with poor reliability and accuracy.

KEY POINTS: • Novice/expert inter-rater reliability improved from poor with 2DUS to moderate/high with 3DUS. • Novice operators using 3DUS correctly classified 57/58 (98%) of infant hips. • DDH can be reliably assessed by novice operators using 3DUS.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Mostofi E, Chahal B, Zonoobi D, et al. Reliability of 2D and 3D ultrasound for infant hip dysplasia in the hands of novice users. Eur Radiol. 2018. PMID: 30159618. doi:10.1007/s00330-018-5699-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。