新手操作者使用二维与三维超声评估婴儿髋关节发育不良的可靠性
本研究纳入30例疑似发育性髋关节发育不良(DDH)婴儿,比较新手与专家操作者行二维超声(2DUS)和三维超声(3DUS)的组内与组间可靠性。2DUS组间可靠性差(ICC=0.10/0.04),3DUS组间可靠性中至高(ICC=0.73-0.83/0.55);新手使用3DUS正确分类57/58(98%)髋关节。结论认为新手操作3DUS的可靠性和准确性接近专家。
要点
- 2DUS组间可靠性差:α角ICC=0.10,髋臼覆盖率ICC=0.04。
- 3DUS组间可靠性中至高:α角ICC=0.73-0.83,髋臼覆盖率ICC=0.55。
- 新手使用3DUS正确分类57/58(98%)婴儿髋关节。
核心结论
- 新手操作者使用3DUS评估DDH的可靠性和准确性接近专家超声医师;新手使用2DUS的可靠性和准确性差。
研究设计与样本
- 前瞻性纳入30例疑似DDH婴儿(平均年龄10.8周),新手(1.5小时培训)与专家(5-15年经验)分别行2DUS和3DUS,每名操作者采集两幅2DUS静态图像和两幅3DUS扫掠图像;以放射科医师审阅专家2DUS作为金标准诊断(正常、临界或发育不良)。
诊断标准与关键数值
- 图像质量采用5分制评估(是/否:完整股骨头、完整髋臼顶、水平髂骨翼、坐骨、无运动/伪影):2DUS新手2.7±1.2 vs 专家4.9±0.3(p=0.04),3DUS新手4.2±1.0 vs 专家4.9±0.3(p=0.99)。2DUS组间可靠性差:α角ICC=0.10,髋臼覆盖率ICC=0.04;3DUS组间可靠性中至高:α角ICC=0.73-0.83,髋臼覆盖率ICC=0.55。3DUS组内可靠性和诊断准确性高于2DUS。
临床应用与阅片要点
- 新手使用3DUS可正确分类57/58(98%)婴儿髋关节,提示3DUS可能使新手操作者可靠地评估DDH。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Developmental dysplasia of the hip (DDH) diagnosis by two-dimensional ultrasound (2DUS) can have poor inter-rater reliability. 3D ultrasound (3DUS) may be more reliably performed, particularly by novice users. We compared intra- and inter-rater reliability between expert and novice operators performing 2DUS and 3DUS for DDH.
MATERIALS AND METHODS: Infants with suspected DDH were assessed with 2DUS and 3DUS. Novice operators had 1.5 h of training and Experts had 5-15 years' experience. Images included two 2DUS static and two 3DUS sweep images per operator. Image quality was assessed by 5-point system (yes/no: full femoral head; full acetabular roof; horizontal iliac wing; os ischium; absent motion/artifact). 2DUS indices (alpha angle, coverage) were measured centrally by a blinded reader with 2 years DDH US experience. 3DUS was post-processed by semi-automated custom software generating acetabular surface models, indices and estimated probability of DDH. Gold-standard diagnosis of each hip as normal, borderline or dysplastic was based on radiologist review of expert 2DUS.
RESULTS: Thirty infants, mean age 10.8 weeks were enrolled. Quality scores were 2.7±1.2 Novice versus 4.9±0.3 Expert for 2DUS (p = 0.04), and 4.2±1.0 Novice versus 4.9±0.3 Expert for 3DUS (p = 0.99). Inter-rater reliability was poor for 2DUS (ICC=0.10 for alpha angle, 0.04 for acetabular coverage) and moderate to high for 3DUS (ICC=0.73-0.83 for alpha angle, 0.55 for acetabular coverage). Intra-rater reliability and diagnostic accuracy was higher for 3DUS than 2DUS.
CONCLUSION: Novice operators can perform 3DUS for DDH with reliability and accuracy approaching expert sonographers. Novices perform 2DUS with poor reliability and accuracy.
KEY POINTS: • Novice/expert inter-rater reliability improved from poor with 2DUS to moderate/high with 3DUS. • Novice operators using 3DUS correctly classified 57/58 (98%) of infant hips. • DDH can be reliably assessed by novice operators using 3DUS.
引用
- Mostofi E, Chahal B, Zonoobi D, et al. Reliability of 2D and 3D ultrasound for infant hip dysplasia in the hands of novice users. Eur Radiol. 2018. PMID: 30159618. doi:10.1007/s00330-018-5699-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。