通过回顾2000余份事件报告评估儿科放射学中患者的潜在风险
本研究回顾了一家大型儿科影像系统5年内提交的2009份事件报告,并与1,071,809次影像检查对比计算事件报告率。结果显示总报告率为0.19%,介入放射学和MRI的报告率较高,住院患者和接受镇静麻醉患者的报告率也较高。作者认为事件报告率可作为潜在患者伤害的替代指标,安全改进应聚焦于这些高风险领域。
要点
- 介入放射学的事件报告率(1.54%)高于其他影像方式,MRI为0.62%。
- 接受镇静麻醉患者的事件报告率(1.27%)高于未镇静患者(0.12%)。
- 住院患者的事件报告率(0.34%)高于门诊(0.1%)和急诊中心(0.14%)。
核心结论
- 以事件报告率作为潜在患者伤害的替代指标,该儿科放射学服务中风险最高的领域是介入放射学、接受镇静的患者和住院患者,风险最低的领域是超声(US)和X线摄影。安全改进工作应聚焦于高风险领域。
研究设计与样本
- 回顾性分析一家大型儿科影像系统2013年至2017年间提交的所有事件报告,按成像方式、患者类型(住院、门诊或急诊中心)及镇静/麻醉使用情况分类,并与同期影像检查总数比较计算事件报告率,进行统计学差异检验。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Incident reporting can be used to inform imaging departments about adverse events and near misses.
OBJECTIVE: To study incident reports submitted during a 5-year period at a large pediatric imaging system to evaluate which imaging modalities and other factors were associated with a greater rate of filed incident reports.
MATERIALS AND METHODS: All incident reports filed between 2013 and 2017 were reviewed and categorized by modality, patient type (inpatient, outpatient or emergency center) and use of sedation/anesthesia. The number of incident reports was compared to the number of imaging studies performed during that time period to calculate an incident report rate for each factor. Statistical analysis of whether there were differences in these rates between factors was performed.
RESULTS: During the study period, there were 2,009 incident reports filed and 1,071,809 imaging studies performed for an incident report rate of 0.19%. The differences in rates by modality were statistically significant (P=0.0001). There was a greater rate of incident reports in interventional radiology (1.54%) (P=0.0001) and in magnetic resonance imaging (MRI) (0.62%) (P=0.001) as compared to other imaging modalities. There was a higher incident report rate for inpatients (0.34%) as compared to outpatient (0.1%) or emergency center (0.14%) (P=0.0001). There was a higher rate of incident reports for patients under sedation (1.27%) as compared to non-sedated (0.12%) (P=0.0001).
CONCLUSION: Using incident report rates as a proxy for potential patient harm, the areas of our pediatric radiology service that are associated with the greatest potential for issues are interventional radiology, sedated patients, and inpatients. The areas associated with the least risk are ultrasound (US) and radiography. Safety improvement efforts should be focused on the high-risk areas.
引用
- Snyder EJ, Zhang W, Jasmin KC, et al. Gauging potential risk for patients in pediatric radiology by review of over 2,000 incident reports. Pediatr Radiol. 2018. PMID: 30159593. doi:10.1007/s00247-018-4238-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。