成人膝关节全自动10分钟3D CAIPIRINHA SPACE TSE MRI:一项多中心、多阅片者、多场强验证研究
本研究纳入3 T症状受试者100例和1.5 T症状受试者50例,比较10分钟3D CAIPIRINHA SPACE TSE与20分钟2D TSE标准参考方案对膝关节内部紊乱的诊断价值。互换性分析显示3D MRI可替代2D方案,且3D MRI在内外侧半月板撕裂、软骨缺损和骨髓水肿检测中共同配对精确匹配比例显著更高(P<0.01)。3D TSE的阅片者间可靠性(κ=0.941)和诊断确定性显著高于2D TSE(P<0.01)。
要点
- 10分钟3D CAIPIRINHA SPACE TSE可替代20分钟2D TSE标准方案用于膝关节内部紊乱评估。
- 3D MRI在内外侧半月板撕裂、软骨缺损和骨髓水肿检测中共同配对精确匹配比例显著更高(P<0.01)。
- 3D TSE阅片者间可靠性(κ=0.941)和诊断确定性显著高于2D TSE(P<0.01)。
核心结论
- 10分钟3D CAIPIRINHA SPACE TSE MRI方案在个体患者诊断中产生与20分钟2D TSE标准参考方案相似的结果,可替代后者用于膝关节内部紊乱评估,且3D检查的阅片者间可靠性、方法间一致性和阅片者确定性总体更高。
研究设计与样本
- 经内部审查委员会批准并获前瞻性知情同意后开展的多中心、多阅片者、多场强验证研究;3 T症状受试者100例和1.5 T症状受试者50例接受10分钟3D CAIPIRINHA SPACE TSE与20分钟2D TSE标准参考方案MRI检查。
关键影像表现/征象
- 由两名接受过 fellowship 培训的肌肉骨骼放射科医师以匿名随机方式评估结构异常。
- 3D MRI在内外侧半月板撕裂、软骨缺损和骨髓水肿检测中共同配对精确匹配比例显著更高(P<0.01)。
诊断标准与关键数值
- 3D TSE总体阅片者间可靠性为96%精确匹配(κ=0.941),2D TSE为89%精确匹配(κ=0.842),差异P<0.01。
- 方法间一致性良好(κ=0.736;范围0.579-1.000)。
- 阅片者间可靠性:2D TSE κ=0.748(0.603-1.000),3D TSE κ=0.901(0.797-1.000),3D显著高于2D(P<0.01)。
- 互换性分析显示3D MRI可替代2D MRI方案。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to test the hypothesis that magnetic resonance imaging (MRI) of the knee with 10-minute 3-dimensional (3D) controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) turbo spin echo (TSE) protocols can replace 20-minute 2-dimensional (2D) TSE standard-of-reference protocols for the diagnosis of internal derangement.
MATERIALS AND METHODS: After internal review board approval and prospective informed consent, 100 symptomatic subjects underwent MRI of the knee at 3 T and 50 symptomatic subjects at 1.5 T, consisting of 10-minute 3D CAIPIRINHA SPACE TSE and 20-minute standard-of-reference 2D TSE protocols. Two fellowship-trained musculoskeletal radiologists assessed the studies in an anonymized and randomized fashion for structural abnormalities. Descriptive statistics, interreader reliability, intermethod concordance, diagnostic definitiveness, and interchangeability tests were applied. P values equal to or smaller than 0.01 were considered significant.
RESULTS: The interchangeability analysis showed that the 3D MRI can replace the 2D MRI protocols, whereas a superiority of 3D MRI was suggested statistically for the detection of medial and lateral meniscal tears, cartilage defects, and bone marrow edema by significantly higher common pair exact match proportions of readers (P < 0.01, respectively).The overall interreader reliabilities were 89% of exact matches for 2D TSE (κ, 0.842) and 96% of exact matches for 3D TSE (κ, 0.941) (P < 0.01). There was good intermethod concordance (κ, 0.736; range, 0.579-1.000). The interreader reliability (2D TSE: κ, 0.748 [0.603-1.000]; 3D TSE: κ, 0.901 [0.797-1.000]) and diagnostic definitiveness were significantly higher for the 3D than 2D MRI (P < 0.01).
CONCLUSIONS: 10-minute 3D CAIPIRINHA SPACE TSE MRI protocols can replace 20-minute 2D TSE standard-of-reference MRI protocols for the evaluation of internal derangement of the knee by producing similar results in individual patient diagnoses, whereas interpretations of 3D CAIPIRINHA SPACE TSE MRI examinations resulted in an overall higher interreader reliability, intermethod concordance, and reader definitiveness.
引用
- Del Grande F, Delcogliano M, Guglielmi R, et al. Fully Automated 10-Minute 3D CAIPIRINHA SPACE TSE MRI of the Knee in Adults: A Multicenter, Multireader, Multifield-Strength Validation Study. Invest Radiol. 2018. PMID: 30085948. doi:10.1097/RLI.0000000000000493
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。