同相位与反相位化学位移成像鉴别椎体骨髓良恶性病变的诊断效能:一项Meta分析
该Meta分析纳入12项研究共591例患者663个病灶,评估同相位与反相位化学位移成像(CSI)鉴别椎体骨髓良恶性病变的诊断效能。CSI汇总敏感度0.92、特异度0.89、HSROC AUC 0.95;鉴别良恶性压缩骨折的敏感度0.96、特异度0.89、AUC 0.93。作者推荐采用短TR、小翻转角和Dixon法以提高特异度。
要点
- CSI鉴别椎体骨髓良恶性病变汇总敏感度0.92、特异度0.89、HSROC AUC 0.95。
- 鉴别良恶性压缩骨折敏感度0.96、特异度0.89、AUC 0.93。
- 短TR(<100 ms)、小翻转角(<50°)和Dixon法倾向于有更高特异度。
核心结论
- 同相位与反相位CSI对鉴别椎体骨髓良恶性病变具有 excellent 诊断效能,推荐采用短TR、小翻转角和Dixon法以提高诊断准确性和特异度。
研究设计与样本
- Meta分析,检索PubMed和EMBASE数据库,纳入12项诊断准确性研究,共591例患者663个病灶,以组织病理学或最佳参考标准为对照,采用QUADAS-2工具评价方法学质量,行双变量模型和HSROC模型分析。
诊断标准与关键数值
- CSI鉴别良恶性椎体骨髓病变汇总敏感度0.92(95% CI 0.84-0.96),汇总特异度0.89(95% CI 0.81-0.93),HSROC AUC 0.95(95% CI 0.93-0.97)。
- CSI鉴别良恶性压缩骨折汇总敏感度0.96(95% CI 0.81-0.99),汇总特异度0.89(95% CI 0.83-0.93),HSROC AUC 0.93(95% CI 0.91-0.95)。
临床应用与阅片要点
- 作者推荐采用短TR(<100 ms)、小翻转角(<50°)和Dixon法进行CSI检查,以提高特异度。
- Meta回归显示研究人群、层厚(<5 mm)、最小TE(<2.3 ms)、翻转角(<50°)和盲法也显著影响异质性(p<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study was to assess the diagnostic performance of in-phase and opposed-phase chemical-shift imaging (CSI) for differentiating benign and malignant vertebral bone marrow lesions (BMLs).
MATERIALS AND METHODS: The PubMed and EMBASE databases were searched for diagnostic accuracy studies comparing conventional gradient-echo CSI or the Dixon method for differentiating benign and malignant vertebral BMLs with histopathologic or best-value comparator results. Methodologic quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Bivariate modeling and hierarchical summary ROC (HSROC) modeling were performed to evaluate the diagnostic performance of CSI. For heterogeneity exploration, we performed meta-regression analyses.
RESULTS: Twelve studies including 663 lesions of 591 patients were included. CSI showed a pooled sensitivity of 0.92 (95% CI, 0.84-0.96), pooled specificity of 0.89 (95% CI, 0.81-0.93), and HSROC AUC of 0.95 (95% CI, 0.93-0.97) for differentiating benign from malignant vertebral BMLs. The corresponding values for differentiating benign from malignant compression fractures were 0.96 (95% CI, 0.81-0.99), 0.89 (95% CI, 0.83-0.93), and 0.93 (95% CI, 0.91-0.95). In meta-regression analysis, minimum TR (< 100 ms), flip angle (< 50°), and Dixon method tended to have higher specificity. Study population, slice thickness (< 5 mm), minimum TE (< 2.3 ms), flip angle (< 50°), and blinding also significantly affected heterogeneity (p < 0.05).
CONCLUSION: In-phase and opposed-phase CSI has excellent diagnostic performance for differentiating benign and malignant vertebral BMLs. CSI with a short TR, small flip angle, and Dixon method is recommended for more accurate diagnosis as specificity increases.
引用
- Suh CH, Yun SJ, Jin W, et al. Diagnostic Performance of In-Phase and Opposed-Phase Chemical-Shift Imaging for Differentiating Benign and Malignant Vertebral Marrow Lesions: A Meta-Analysis. AJR Am J Roentgenol. 2018. PMID: 30160981. doi:10.2214/AJR.17.19306
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。