合成磁共振成像序列用于脊柱成像的可行性研究
该研究纳入38例有感染、退变或肿瘤临床指征的患者,行脊柱MR成像(颈椎11例、胸椎8例、腰骶椎19例),在常规矢状位T1 TSE、T2 TSE和STIR TSE序列基础上加做SyntAc序列(采集时间5分40秒)。结果显示合成T1加权、T2加权和STIR图像质量 adequate,采集时间较常规MR减少53%,图像质量评级均为「良好」,病灶显示一致性的Cohen κ为0.737;合成序列中白色像素/尖峰噪声及血流伪影更常见,尤其合成STIR。
要点
- 合成MR可在单次5分40秒采集内生成T1WI、T2WI和STIR多种对比及定量图,采集时间较常规减少53%。
- 合成与常规图像质量均评为「良好」,病灶显示一致性Cohen κ为0.737。
- 合成序列白色像素/尖峰噪声及血流伪影更常见,尤其合成STIR。
核心结论
- 合成MR成像用于脊柱成像可行,总体图像质量和诊断信心良好;非可忽略的时间节省、定量测量能力及单次采集生成多种对比,提示其在临床常规中前景广阔。
研究设计与样本
- 可行性研究,纳入38例有感染、退变或肿瘤临床指征的患者,行脊柱MR成像(颈椎11例、胸椎8例、腰骶椎19例),在常规矢状位T1 TSE、T2 TSE和STIR TSE序列基础上加做SyntAc序列,采集时间5分40秒。
关键影像表现/征象
- 合成T1加权、T2加权和STIR图像质量 adequate,图像质量评级合成与常规均为「良好」。
- 合成序列中白色像素/尖峰噪声及血流伪影更常见,尤其合成STIR。
- 病灶显示一致性的Cohen κ为0.737。
临床应用与阅片要点
- 合成MR可在5分40秒采集时间内生成T1WI、T2WI和STIR多种对比,采集时间较常规减少53%。
- 合成序列尤其合成STIR中白色像素/尖峰噪声及血流伪影更常见,阅片时需注意。
局限性
- 合成序列中白色像素/尖峰噪声及血流伪影更常见,尤其合成STIR。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Synthetic MR imaging is a method that can produce multiple contrasts from a single sequence, as well as quantitative maps. Our aim was to determine the feasibility of a synthetic MR image for spine imaging.
MATERIALS AND METHODS: Thirty-eight patients with clinical indications of infectious, degenerative, and neoplastic disease underwent an MR imaging of the spine (11 cervical, 8 dorsal, and 19 lumbosacral MR imaging studies). The SyntAc sequence, with an acquisition time of 5 minutes 40 seconds, was added to the usual imaging protocol consisting of conventional sagittal T1 TSE, T2 TSE, and STIR TSE.
RESULTS: Synthetic T1-weighted, T2-weighted, and STIR images were of adequate quality, and the acquisition time was 53% less than with conventional MR imaging. The image quality was rated as "good" for both synthetic and conventional images. Interreader agreement concerning lesion conspicuity was good with a Cohen κ of 0.737. Artifacts consisting of white pixels/spike noise across contrast views, as well as flow artifacts, were more common in the synthetic sequences, particularly in synthetic STIR. There were no statistically significant differences between readers concerning the scores assigned for image quality or lesion conspicuity.
CONCLUSIONS: Our study shows that synthetic MR imaging is feasible in spine imaging and produces, in general, good image quality and diagnostic confidence. Furthermore, the non-negligible time savings and the ability to obtain quantitative measurements as well as to generate several contrasts with a single acquisition should promise a bright future for synthetic MR imaging in clinical routine.
引用
- Vargas MI, Drake-Pérez M, Delattre BMA, et al. Feasibility of a Synthetic MR Imaging Sequence for Spine Imaging. AJNR Am J Neuroradiol. 2018. PMID: 30072367. doi:10.3174/ajnr.A5728
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。