乳腺癌患者乳腺磁共振成像上的肌肉质量评估:CT腰大肌面积与MRI胸肌面积的比较
回顾性纳入26例同时有体部CT和乳腺MRI的乳腺癌患者,两位放射科医生分别测量CT腰大肌面积(1.25mm和5mm层厚)和MRI轴位T1WI胸肌面积。CT腰大肌面积与MRI胸肌面积的Pearson相关系数为0.70(95%CI 0.41-0.81),决定系数0.49。结论认为两者相关性很好,乳腺MRI胸肌面积或可用于估计乳腺癌女性肌肉质量。
要点
- 乳腺MRI轴位T1WI上测量的胸肌面积与CT腰大肌面积相关系数r=0.70(95%CI 0.41-0.81)。
- CT腰大肌面积在1.25mm与5mm层厚图像的组间一致性分别为k=0.85和k=0.79。
- MRI胸肌面积组间一致性k=0.61,组内一致性reader1为0.62、reader2为0.64。
核心结论
- CT图像上腰大肌面积与MRI上胸肌面积相关性很好,乳腺MRI胸肌面积或可用于估计乳腺癌女性肌肉质量。
研究设计与样本
- 回顾性研究,经机构审查委员会批准,纳入26例同时有体部CT和乳腺MRI的乳腺癌女性;两位放射科医生在1.25mm和5mm体部CT图像上计算腰大肌面积,两位放射科医生在轴位T1加权图像上测量胸肌面积;统计分析包括读者间和读者内一致性以及CT腰大肌面积与MRI胸肌面积的相关性。
诊断标准与关键数值
- CT腰大肌面积与MRI胸肌面积的Pearson相关系数r=0.70(95%CI 0.41-0.81),决定系数0.49。
- 轴位1.25mm和5mm CT图像上腰大肌面积的读者间一致性分别为k=0.85和k=0.79。
- 读者1在1.25mm和5mm CT图像上腰大肌面积的读者内一致性分别为k=0.98和k=0.94。
- 读者2在1.25mm和5mm CT图像上腰大肌面积的读者内一致性分别为k=0.95和k=0.94。
- 轴位T1加权图像上胸肌面积的读者间一致性k=0.61,读者1和读者2的读者内一致性分别为0.62和0.64。
临床应用与阅片要点
- 作者认为乳腺MRI胸肌面积或可用于估计乳腺癌女性肌肉质量。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the correlation between psoas muscle area (TPA) on CT images and pectoralis muscle area (PMA) on MRI in breast cancer patients.
METHODS: This retrospective study was institutional review board approved and women involved gave written informed consent. Twenty six patients with both body CT and breast MRI available were evaluated. Two radiologists calculated TPA on 1.25-mm and 5-mm body CT images. Two radiologists measured PMA on axial T1-weighted images. Statistical analysis included inter- and intra-reader agreement and correlation between TPA on CT and PMA on MRI.
RESULTS: The Pearson r correlation coefficient was 0.70 (95% CI 0.41-0.81) and the coefficient of determination was 0.49. The inter-reader agreement was k = 0.85 and k = 0.79 for axial 1.25-mm and 5-mm CT images, respectively. The intra-reader agreement of reader 1 was k = 0.98 and k = 0.94 for 1.25-mm and 5-mm CT images, respectively. The intra-reader agreement of reader 2 was k = 0.95 and k = 0.94 for 1.25-mm and 5-mm CT images, respectively. On axial T1-weighted images, the inter-reader agreement for radiologists evaluating the PMA was k = 0.61. Intra-observer agreement of reader 1 and reader 2 for PMA estimation was good (0.62 and 0.64), respectively.
CONCLUSION: The correlation between TPA on CT images and PMA on MRI was very good. Pectoralis muscle area on breast MRI could be useful to estimate muscle mass in women with breast cancer.
KEY POINTS: • Pectoralis muscle area can be estimated on breast MRI • Total psoas area on CT and pectoralis muscle area on MRI are strongly correlated • Pectoralis muscle area on breast MRI could estimate the skeletal muscle mass.