文献速递乳腺MR乳腺X线

乳腺磁共振成像与乳腺X线摄影在术前检测和测量纯导管原位癌中的准确性比较:一项回顾性分析

Accuracy of Breast Magnetic Resonance Imaging Compared to Mammography in the Preoperative Detection and Measurement of Pure Ductal Carcinoma In Situ: A Retrospective Analysis.
PubMed 文献 · Acad Radiol · 2018-08-24

回顾性分析295例活检证实的纯导管原位癌患者,41.7%(123/295)在乳腺X线摄影基础上加做乳腺MRI。乳腺X线摄影漏诊24.4%(30/123),MRI漏诊1.6%(2/123);乳腺X线摄影平均低估尺寸4.6 mm,MRI对低级别高估1 mm、中级别准确、高级别低估1 mm。结论认为MRI在DCIS检测和尺寸评估上优于乳腺X线摄影,并可降低阳性切缘率。

要点

  • 乳腺X线摄影对纯DCIS漏诊率24.4%(30/123),加做MRI后漏诊率降至1.6%(2/123)。
  • 乳腺X线摄影平均低估DCIS尺寸4.6 mm,高级别DCIS低估达10.5 mm(中位数)。
  • MRI对低级别DCIS高估1 mm(中位数)、中级别准确、高级别低估1 mm。

核心结论

  • MRI在纯DCIS的检测和尺寸评估上优于乳腺X线摄影,并可降低阳性切缘率。

研究设计与样本

  • 回顾性分析295例活检证实的纯导管原位癌患者,平均年龄57.0岁(范围27-87岁);全部患者接受乳腺X线摄影,41.7%(123/295)加做乳腺MRI;以手术标本组织病理学尺寸为参考标准。

诊断标准与关键数值

  • 乳腺X线摄影对DCIS漏诊24.4%(30/123),MRI漏诊1.6%(2/123);乳腺X线摄影平均低估尺寸4.6 mm,对低级别DCIS尺寸准确、中级别低估1 mm(中位数)、高级别低估10.5 mm(中位数);MRI对低级别DCIS高估1 mm(中位数)、中级别准确、高级别低估1 mm(中位数)。

临床应用与阅片要点

  • 原文结论认为MRI在DCIS检测和尺寸评估上优于乳腺X线摄影,并可降低阳性切缘率;背景实质强化不影响肿瘤检测和测量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Ductal carcinoma in situ (DCIS) hinders imaging detection due to multifocal appearance and discontinuous growth. Preoperative determination of its extent is therefore challenging. Aim of this study was to investigate the additional benefit of breast magnetic resonance imaging (MRI) to mammography (MG) in the diagnosis of DCIS according to size and grading.

MATERIALS AND METHODS: Retrospective analysis of 295 patients with biopsy-proven, pure DCIS. Mean patient age was 57.0 years (27-87 years). All patients obtained MG. Additional MRI was performed in 41.7% (123/295). Mammographic breast density, background parenchymal enhancement (BPE), tumor size and grading were analysed. Tumor size on MG and MRI were compared to histopathological size of the surgical specimen.

RESULTS: Mean tumor size was 39.6 mm. DCIS was occult on MG in 24.4% (30/123) and on MRI in 1.6% (2/123). Size was underestimated by 4.6 mm (mean) mammographically. DCIS was high grade in 54.5% (67/123), intermediate grade in 40.7% (50/123) and low grade in 4.9% (6/123). MG was exact regarding tumor size in low grade DCIS, underestimated intermediate grade DCIS by 1 mm (median) and high grade DCIS by 10.5 mm. MRI overestimated low grade DCIS by 1 mm (median), was exact regarding intermediate grade DCIS and underestimated high grade DCIS by 1 mm. BPE did not influence tumor detection and measurement.

CONCLUSION: MRI outperforms MG in the detection and size estimation of DCIS and can reduce positive margin rates.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Preibsch H, Beckmann J, Pawlowski J, et al. Accuracy of Breast Magnetic Resonance Imaging Compared to Mammography in the Preoperative Detection and Measurement of Pure Ductal Carcinoma In Situ: A Retrospective Analysis. Acad Radiol. 2018. PMID: 30149976. doi:10.1016/j.acra.2018.07.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。