文献速递乳腺US乳腺X线

超声引导下空芯针活检确诊的导管原位癌中浸润性乳腺癌的预测因素

Predictors of Invasive Breast Cancer in Patients With Ductal Carcinoma In Situ in Ultrasound-Guided Core Needle Biopsy.
PubMed 文献 · J Ultrasound Med · 2018-08-01

回顾性分析80个超声引导下活检确诊的导管原位癌病灶,27个(33.8%)术后病理升级为浸润性癌。BI-RADS超声评估分类(P=.015)、核分级(P=.005)及剪切波弹性成像最大硬度值(纯DCIS组119.04 vs 85.33 kPa,P=.041)与浸润性成分相关。

要点

  • 超声BI-RADS分类和核分级与DCIS术后升级为浸润性癌显著相关。
  • 剪切波弹性成像最大硬度值在纯DCIS组较低(119.04 vs 85.33 kPa,P=.041)。
  • 常规BI-RADS超声描述词(形态、方向、边缘、回声)与升级无显著相关。

核心结论

  • 基于超声表现的BI-RADS分类、剪切波弹性成像最大硬度值和DCIS核分级可预测DCIS中是否存在浸润性成分。

研究设计与样本

  • 回顾性研究,纳入2015年1月至2016年9月共80个超声引导下活检确诊的DCIS病灶,患者均行术前乳腺X线摄影、B型超声和剪切波弹性成像。

诊断标准与关键数值

  • BI-RADS超声评估分类与肿块浸润性显著相关(P=.015)。
  • 核分级与肿块浸润性显著相关(P=.005)。
  • 剪切波弹性成像最大硬度值在纯DCIS组为119.04 kPa,在含浸润性成分组为85.33 kPa(P=.041)。
  • BI-RADS超声描述词(形态、方向、边缘、回声)与组织学升级率无显著相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine predictors of invasiveness of lesions with US-guided biopsy-confirmed ductal carcinoma in situ (DCIS), focusing on US features, including shear wave elastography (SWE).

METHODS: From January 2015 to September 2016, a total of 80 lesions with US-guided biopsy-confirmed DCIS were detected in patients who underwent preoperative mammography, B-mode US, and SWE. Data were retrospectively reviewed from clinical records, pathologic reports, and imaging assessments. Imaging data included mammographic findings, B-mode US findings based on the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS), and the mean and maximum elasticity values on SWE. The final BI-RADS assessment, including the degree of elasticity of the mass, was evaluated. Continuous variables were examined by an independent t test, and categorical variables were examined by the Fisher exact test. The independent factors for predicting a histologic upgrade were evaluated by a multivariate logistic regression analysis.

RESULTS: Among the 80 lesions, 27 (33.8%) showed an invasive component after surgical excision. None of the BI-RADS US descriptors, which include shape, orientation, margin, and echogenicity, showed a significant correlation with the rate of a histologic upgrade to invasive cancer. However, the BI-RADS assessment category (P = .015) and nuclear grade (P = .005) were significantly correlated with invasiveness of the mass. The maximum stiffness value was lower in the pure DCIS group (119.04 vs 85.33 kPa; P = .041).

CONCLUSIONS: The BI-RADS category based on US findings, maximum stiffness value on SWE, and nuclear grade of DCIS are predictive of invasive components in DCIS.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Shin YJ, Kim SM, Yun B, et al. Predictors of Invasive Breast Cancer in Patients With Ductal Carcinoma In Situ in Ultrasound-Guided Core Needle Biopsy. J Ultrasound Med. 2018. PMID: 30069893. doi:10.1002/jum.14722

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。