3T场强下乳腺对比增强与非增强扩散加权成像
这项前瞻性研究纳入62个经活检证实的乳腺病灶,在3T MRI下比较注射钆对比剂前后四个回波平面扩散加权序列(b值0和850、0和1000 s/mm²)的ADC值。注射对比剂后b=850和1000 s/mm²的ADC值低于未增强测量值(p<0.05),但ROC分析显示各序列AUC相似,敏感度和特异度未受显著影响。
要点
- 3T乳腺DWI中,静脉注射钆对比剂后b=850和1000 s/mm²的ADC值较增强前降低(p<0.05)。
- 对比剂对ADC的影响幅度不大,敏感度和特异度未受显著影响。
- 不同b值扩散序列的ROC曲线下面积相似。
核心结论
- 静脉注射对比剂会降低ADC值,但对比剂效应不大,敏感度和特异度未受显著影响。
研究设计与样本
- 前瞻性研究,纳入62个经活检证实的乳腺病灶,在3T MRI下使用四个回波平面扩散加权序列(重复时间7,100 ms,回波时间84 ms),b值分别为0和850、0和1,000 s/mm²;第一对DWI序列在静脉注射对比剂前采集,第二对在注射对比剂后6.5分钟(动态T1序列后即刻)采集;在病灶内绘制自由形态感兴趣区(ROI),排除邻近正常组织、坏死或囊性成分后计算ADC值;采用配对样本t检验比较注射对比剂前后ADC测量值的差异,并计算每个扩散序列的敏感度、特异度、阳性预测值、阴性预测值和曲线下面积。
关键影像表现/征象
- 58个病灶为肿块,4个病灶为非肿块样强化(NMLEs),其中2个NMLEs为恶性、2个为良性。
诊断标准与关键数值
- 注射对比剂后b=850和1,000 s/mm²的ADC测量值低于未增强测量值(p<0.05)。
- ROC分析显示不同扩散序列之间的曲线下面积值相似。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the effect of intravenous gadolinium contrast agent on diffusion-weighted sequences and apparent diffusion coefficient (ADC) measurements at 3 T.
MATERIALS AND METHODS: Sixty-two biopsy-proven breast lesions were included in this prospective study. Magnetic resonance imaging (MRI) was performed at 3 T, using four echo-planar diffusion-weighted sequences (7,100 ms repetition time, 84 ms echo time) with b-values of 0 and 850, and 0 and 1,000 s/mm2. The first pair of DWI sequences was taken before intravenous contrast medium injection. The second pair of sequences was taken 6.5 minutes after intravenous contrast medium administration (right after the dynamic T1 sequence). A freeform region of interest (ROI) was drawn inside the lesion excluding adjacent normal tissue, necrotic, or cystic components and ADC values were calculated. The paired samples t-test was used to assess differences between ADC measurements before and after intravenous contrast medium administration. Sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve were calculated for each diffusion sequence.
RESULTS: Twenty-seven malignant and 35 benign lesions were analysed. Fifty-eight lesions were masses, and four lesions were non-mass-like enhancements (NMLEs). Two of the NMLEs were malignant, and two were benign lesions. The contrast-enhanced ADC measurements were lower than the unenhanced measurements on b=850 and 1,000 s/mm2 (p<0.05). The receiver operating characteristic (ROC) analysis displayed similar area under the curve values between the different diffusion sequences.
CONCLUSION: The injection of intravenous contrast medium reduces ADC values; however, the effect of contrast medium is modest. Sensitivity and specificity are not significantly affected.
引用
- Fanariotis M, Tsougos I, Vlychou M, et al. Contrast-enhanced and unenhanced diffusion-weighted imaging of the breast at 3 T. Clin Radiol. 2018. PMID: 30060888. doi:10.1016/j.crad.2018.06.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。