文献速递妇产影像介入MR

拟行MR引导高强度聚焦超声治疗的子宫肌瘤Funaki分型的多参数MRI特征研究

Multiparametric MRI Characterization of Funaki Types of Uterine Fibroids Considered for MR-Guided High-Intensity Focused Ultrasound (MR-HIFU) Therapy.
PubMed 文献 · Acad Radiol · 2018-07-29

一项前瞻性研究纳入48例有症状子宫肌瘤女性共100个肌瘤,在3T磁共振上行多参数MRI,比较Funaki 1、2、3型肌瘤的大小、灌注及扩散/体素内不相干运动参数差异。结果显示3型肌瘤的表观扩散系数和D值显著高于1型和2型,D值取1×10⁻³ mm²/s时诊断3型肌瘤的准确率76%、敏感度71%、特异度77%。

要点

  • 3型肌瘤的表观扩散系数和D值显著高于1型和2型肌瘤。
  • 3型肌瘤的转运常数显著高于1型,但与2型无显著差异。
  • D值取1×10⁻³ mm²/s诊断Funaki 3型肌瘤准确率76%。

核心结论

  • 多参数MRI定量参数可能有助于在MR引导高强度聚焦超声治疗前更客观地筛选患者。

研究设计与样本

  • 前瞻性、经机构审查委员会批准、符合《健康保险携带与责任法案》的研究,2013年12月至2015年4月纳入48例有症状子宫肌瘤女性,在3T磁共振上行矢状/轴位T2加权快速自旋回波、矢状扩散加权及矢状动态对比增强3D T1加权梯度回波成像。

关键影像表现/征象

  • 全部肌瘤基于T2加权成像分为Funaki 1、2、3型。
  • 共评估100个肌瘤,其中1型20个、2型66个、3型14个。

诊断标准与关键数值

  • 3型肌瘤的表观扩散系数显著高于1型(P<0.0001)和2型(P=0.004)。
  • 3型肌瘤的D值显著高于1型(P<0.0001)和2型(P<0.0001)。
  • 3型肌瘤的转运常数显著高于1型(P=0.0357),但与2型无显著差异(P=0.0752)。
  • D值取1×10⁻³ mm²/s诊断Funaki 3型肌瘤的准确率76%、敏感度71%、特异度77%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To compare quantitative multiparametric magnetic resonance imaging (mpMRI) data of symptomatic uterine fibroids being considered for MR-guided high-intensity focused ultrasound ablation with fibroid characterization based on the Funaki Classification scheme.

MATERIALS AND METHODS: This was a prospective, Institutional Review Board -approved, Health Insurance Portability, and Accountability Act-compliant study. Informed consent was obtained. From December 2013 to April 2015, 48 women with symptomatic fibroids underwent screening with mpMRI protocol including sagittal/axial T2-weighted fast spin-echo, sagittal diffusion-weighted, and sagittal dynamic contrast-enhanced 3D T1-weighted gradient echo imaging on a 3T magnet. All fibroids were assigned Funaki type 1, 2, or 3 based on T2-weighted imaging. Differences in size, perfusion, and diffusion/intravoxel incoherent motion parameters among the three Funaki types were determined using linear mixed model. A logistic regression analysis was performed to select the best model in predicting type 3 fibroids.

RESULTS: A total of 100 fibroids were assessed (20 type 1, 66 type 2, and 14 type 3). Apparent diffusion coefficient and D of type 3 fibroids were significantly higher than those of type 1 (P < 0.0001, P < 0.0001) and 2 fibroids (P = 0.004, P < 0.0001) respectively. Transfer constant of type 3 fibroids was significantly higher than type 1 (P = 0.0357), but not than type 2 (P = 0.0752). A cutoff value of D = 1 × 10-3 mm2/s offers an accuracy, sensitivity, and specificity of 76%, 71%, and 77%, respectively, for the diagnosis of Funaki 3 fibroids.

CONCLUSION: mpMRI-derived quantitative parameters may enable a more objective selection of patients prior to MR-guided high-intensity focused ultrasound therapy.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Andrews S, Yuan Q, Bailey A, et al. Multiparametric MRI Characterization of Funaki Types of Uterine Fibroids Considered for MR-Guided High-Intensity Focused Ultrasound (MR-HIFU) Therapy. Acad Radiol. 2018. PMID: 30064919. doi:10.1016/j.acra.2018.05.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。