文献速递介入技术与安全CT

可转向穿刺针用于CT引导下神经丛阻滞

Use of a steerable needle for CT-guided nerve plexus blockade.
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

回顾性评估23例CT引导下神经丛阻滞,其中13例使用新型可转向21G针,10例使用标准针。可转向针组6/13(46%)操作中成功避开肾脏或其他器官到达靶区,肾脏穿刺0/13;标准针组肾脏穿刺4/10(40%),差异有统计学意义(P=0.02)。两组临床获益(P=1.00)与并发症(P=0.56)无显著差异。作者认为介入放射科医生可能发现该针及其未来迭代版本在神经阻滞以及其他需要避开中间结构的操作中有用。

要点

  • 可转向针在6/13(46%)操作中有利于避开肾脏或其他器官到达靶区。
  • 可转向针组肾脏穿刺0/13,标准针组4/10(40%),P=0.02。
  • 两组临床获益(P=1.00)与并发症(P=0.56)无显著差异。

核心结论

  • 与标准(非可转向)针相比,可转向21G针用于神经丛阻滞时可避开肾脏。

研究设计与样本

  • 回顾性评估23例连续CT引导下神经丛阻滞操作,其中最后13例使用新型可转向针,并与之前10例使用标准针的操作进行比较;证据等级为3级,非随机对照队列。

诊断标准与关键数值

  • 可转向针组13例中6例(46%)操作中可转向针有利于避开肾脏或其他器官到达靶区,其余7例无获益。
  • 可转向针组肾脏穿刺0/13,标准针组肾脏穿刺4/10(40%),P=0.02。
  • 可转向针组与标准针组临床获益无显著差异(P=1.00),并发症无显著差异(P=0.56)。

临床应用与阅片要点

  • 作者认为介入放射科医生可能发现该针及其未来迭代版本在神经阻滞以及其他需要避开中间结构的操作中有用。
  • 观察到3例并发症(1例主要和2例次要),认为与注射有关而非针类型。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Demonstrate the use of a new steerable needle for CT-guided neural plexus blockade to avoid traversing the kidneys.

MATERIALS AND METHODS: Retrospective evaluation of 23 consecutive CT-guided neural plexus blockade procedures in which a new steerable needle was used in the last 13 and compared with the prior 10 procedures in which a standard needle was used.

RESULTS: Use of the steerable needle was beneficial to reach the target area without traversing a kidney or other organs in 6/13 (46%) procedures; in the other 7 procedures there was no benefit. A kidney was traversed in 0/13 procedures performed with the steerable needle. In contrast, a kidney was traversed in 4/10 (40%) procedures using a standard needle (P = 0.02). There was no significant difference in clinical benefit (P = 1.00) or complications (P = 0.56) between procedures using the steerable needle versus a standard needle. Three complications were observed (1 major and 2 minor) felt to be related to the injection and not the needle type.

CONCLUSIONS: The utility of a steerable 21-gauge needle during neural plexus blockades was found to allow for avoidance of the kidneys when compared to a standard (non-steerable) needle. Interventional radiologists may find this needle and its future iterations useful for neural blockades, as well as other procedures, when intervening structures need to be avoided.

LEVEL OF EVIDENCE: Level 3, Non-randomized controlled cohort.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Kriegshauser JS, Knuttinen MG, Zhang N, et al. Use of a steerable needle for CT-guided nerve plexus blockade. Abdom Radiol (NY). 2019. PMID: 30078081. doi:10.1007/s00261-018-1721-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。