文献速递腹部CT

低能量水平与碘基物质分解图像可提高快速kV切换双能CT上胰腺导管腺癌的可见性

Lower energy levels and iodine-based material decomposition images increase pancreatic ductal adenocarcinoma conspicuity on rapid kV-switching dual-energy CT.
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

研究纳入90例胰腺导管腺癌患者行快速kV切换双能CT,评估70 keV、个体优化能量水平和45 keV下肿瘤对比度、大小、CNR及噪声,并比较碘图上肿瘤与实质的标准化碘浓度。中位优化观察能量为51 keV,优化能量水平下CNR最高、对比增益最大,碘图上肿瘤与实质NIC差异有统计学意义,提示低能量水平和碘图可改善肿瘤可见性。

要点

  • 中位优化观察能量水平为51 keV,该水平下肿瘤CNR最高(3.37±0.93)。
  • 优化能量水平较70 keV的对比增益∆70-CNR为63±12,45 keV较优化水平∆CNR-45为31±26 HU。
  • 碘图上肿瘤NIC为0.62±0.03 mg/mL,低于胰腺实质的1.36±0.05 mg/mL(p=0.004)。

核心结论

  • 使用快速kV切换双能CT的低能量水平和碘图可改善肿瘤可见性,可能有助于更好地检出胰腺肿瘤。

研究设计与样本

  • 对90例胰腺导管腺癌病例行快速kV切换双能CT评估,分别在70 keV、个体CNR优化能量水平和45 keV下测量肿瘤对比度差值、肿瘤大小、CNR和噪声,并比较碘图上以主动脉归一化的肿瘤与实质碘浓度。

关键影像表现/征象

  • 肿瘤对比度在70 keV为62±20 HU,优化能量水平为115±48 HU,45 keV为152±48 HU(p<0.001)。
  • 肿瘤最大轴径在70 keV为36.6±5.1 mm,优化能量水平为37.9±4.2 mm,45 keV为38.3±3.7 mm(p=0.015)。
  • CNR在70 keV为1.83±0.72,优化能量水平为3.37±0.93,45 keV为2.36±0.56。
  • 图像噪声在70 keV为23.7±6.8,优化能量水平为39.3±11.6,45 keV为59.5±17.2(p<0.001)。

诊断标准与关键数值

  • 中位优化观察能量水平为51 keV。
  • 对比增益∆70-CNR为63±12,∆CNR-45为31±26 HU(p<0.001)。
  • 碘图上肿瘤NIC为0.62±0.03 mg/mL,胰腺实质NIC为1.36±0.05 mg/mL(p=0.004)。

临床应用与阅片要点

  • 阅片时可关注快速kV切换双能CT的低能量水平图像(中位优化能量51 keV)以提高胰腺导管腺癌的肿瘤对比度和CNR。
  • 碘图上肿瘤NIC(0.62±0.03 mg/mL)低于胰腺实质NIC(1.36±0.05 mg/mL),可辅助识别肿瘤与实质的碘浓度差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Multidetector computed tomography (MDCT) is used in the diagnosis of pancreatic ductal adenocarcinoma (PDAC), but it may be inadequate in some cases. Tumor detection can be improved using rapid kV-switching dual-energy CT (rsDECT) and iodine maps. Our aim this study is to evaluate tumor conspicuity in PDAC cases using rsDECT and iodine maps.

METHODS: Ninety cases with PDAC were evaluated rsDECT. Tumor contrast (HU) differences, tumor size, CNR (contrast-noise ratio), and noise were measured at 70 keV, individual CNR-energy level, and 45 keV, respectively. Quantitative differences in contrast gain ∆70-CNR and ∆CNR-45 were compared. On iodine maps, the iodine concentration measured in the tumor and parenchyma was normalized to the aorta as normalized iodine concentration (NIC) and compared.

RESULTS: The median optimized viewing energy level was 51 keV. The mean ± SD tumor contrast values were 62 ± 20, 115 ± 48, and 152 ± 48 HU (p < 0.001); the largest axial diameters were 36.6 ± 5.1, 37.9 ± 4.2, and 38.3 ± 3.7 mm (p = 0.015); the CNRs were 1.83 ± 0.72, 3.37 ± 0.93, and 2.36 ± 0.56; and the image noise levels were 23.7 ± 6.8, 39.3 ± 11.6, and 59.5 ± 17.2 (p < 0.001) (p < 0.001) for 70 keV, optimized energy level, and 45 keV, respectively. The mean ± SD contrast gain ∆70-CNR was 63 ± 12; and ∆CNR-45 was 31 ± 26 HU (p < 0.001). NICtumor and NICparenchyma values were 0.62 ± 0.03 and 1.36 ± 0.05 mg/mL, respectively (p = 0.004).

CONCLUSION: The use of low energy levels on rsDECT and iodine maps improves tumor conspicuity. This situation may be help better detection of pancreatic tumors.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Aslan S, Camlidag I, Nural MS, et al. Lower energy levels and iodine-based material decomposition images increase pancreatic ductal adenocarcinoma conspicuity on rapid kV-switching dual-energy CT. Abdom Radiol (NY). 2019. PMID: 30155698. doi:10.1007/s00261-018-1754-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。