文献速递腹部技术与安全PETCT

F-18 FDG PET/CT 对结直肠局灶性 FDG 摄取定性诊断准确性的系统评价与荟萃分析

Diagnostic accuracy of F-18 FDG PET/CT for characterization of colorectal focal FDG uptake: a systematic review and meta-analysis.
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

该系统评价与荟萃分析检索 MEDLINE、EMBASE 和 Cochrane Library 至 2018 年 4 月 30 日,纳入 8 项研究共 1451 例患者,评估 F-18 FDG PET/CT 对偶发结直肠局灶性 FDG 摄取的定性诊断效能。汇总敏感度为 0.87(95%CI 0.82-0.90),汇总特异度为 0.83(95%CI 0.76-0.89),汇总 LR+ 为 5.2(95%CI 3.6-7.4),LR- 为 0.16(95%CI 0.12-0.22),汇总 DOR 为 32(95%CI 20-51)。作者结论认为 F-18 FDG PET/CT 显示出良好的敏感度和特异度,但现有文献仍有限,需进一步开展大型多中心研究以证实其诊断准确性。

要点

  • 汇总敏感度 0.87(95%CI 0.82-0.90),汇总特异度 0.83(95%CI 0.76-0.89)。
  • 汇总 LR+ 为 5.2(95%CI 3.6-7.4),LR- 为 0.16(95%CI 0.12-0.22)。
  • 汇总 DOR 为 32(95%CI 20-51)。

核心结论

  • F-18 FDG PET/CT 对偶发结直肠局灶性 FDG 摄取显示出良好的敏感度和特异度。
  • 目前关于 F-18 FDG PET/CT 用于偶发结直肠局灶性 FDG 摄取定性的文献仍有限,需进一步开展大型多中心研究以证实其诊断准确性。

研究设计与样本

  • 系统评价与荟萃分析,检索 MEDLINE、EMBASE 和 Cochrane Library 数据库,检索时间自各库最早可检索日期至 2018 年 4 月 30 日。
  • 纳入评估 F-18 FDG PET/CT 对偶发结直肠局灶性 FDG 摄取诊断效能的研究,共纳入 8 项研究、1451 例患者。
  • 汇总各研究敏感度和特异度,计算阳性和阴性似然比(LR+ 和 LR-),并构建汇总受试者工作特征曲线。

关键影像表现/征象

  • F-18 FDG PET/CT 用于偶发结直肠局灶性 FDG 摄取的汇总敏感度为 0.87(95%CI 0.82-0.90),无 heterogeneity(χ2=10.84,p=0.37)。
  • 汇总特异度为 0.83(95%CI 0.76-0.89),存在 heterogeneity(χ2=130.1,p=0.00)。

诊断标准与关键数值

  • F-18 FDG PET/CT 对偶发结直肠局灶性 FDG 摄取的汇总敏感度为 0.87(95%CI 0.82-0.90),汇总特异度为 0.83(95%CI 0.76-0.89)。
  • 汇总 LR+ 为 5.2(95%CI 3.6-7.4),汇总 LR- 为 0.16(95%CI 0.12-0.22)。
  • 汇总 DOR 为 32(95%CI 20-51)。

局限性

  • 目前关于 F-18 FDG PET/CT 用于偶发结直肠局灶性 FDG 摄取定性的文献仍有限。
  • 需进一步开展大型多中心研究以证实 F-18 FDG PET/CT 对偶发结直肠局灶性 FDG 摄取定性的诊断准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: We aimed to explore the role of the diagnostic accuracy of F-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) for characterization of incidental colorectal focal FDG uptake through a systematic review and meta-analysis.

METHODS: The MEDLINE, EMBASE, and Cochrane Library database, from the earliest available date of indexing through April 30, 2018, were searched for studies evaluating the diagnostic performance of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR-), and constructed summary receiver operating characteristic curves.

RESULTS: Across 8 studies (1451 patients), the pooled sensitivity for F-18 FDG PET/CT was 0.87 (95% CI 0.82-0.90) without heterogeneity (χ2 = 10.84, p = 0.37) and a pooled specificity of 0.83 (95% CI 0.76-0.89) with heterogeneity (χ2 = 130.1, p = 0.00). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 5.2 (95% CI 3.6-7.4) and negative likelihood ratio (LR-) of 0.16 (95% CI 0.12-0.22). The pooled DOR was 32 (95% CI 20-51).

CONCLUSION: F-18 FDG PET/CT demonstrated good sensitivity and specificity for characterization of incidental colorectal focal FDG uptake. At present, the literature regarding the use of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。