文献速递腹部外周血管CT

重建技术对腹部CT血管成像质量的影响:前向投影基于模型的迭代重建方案(FIRST)与常规重建方法的比较

Effects of reconstruction technique on the quality of abdominal CT angiography: A comparison between forward projected model-based iterative reconstruction solution (FIRST) and conventional reconstruction methods.
PubMed 文献 · Eur J Radiol · 2018-07-20

本研究对60例患者的腹部CTA图像分别用FBP、AIDR 3D和FIRST三种算法重建,客观评估腹主动脉、腹腔干、肠系膜上动脉、肾动脉和右肝动脉的噪声、SNR和CNR,并由两名放射科医生对周围动脉图像质量进行主观评分。结果显示FIRST和AIDR 3D较FBP显著降低噪声并提高SNR和CNR,FIRST在右肝动脉CNR最高,且被两名医生评为周围腹部动脉图像质量最佳。

要点

  • FIRST和AIDR 3D较FBP显著降低图像噪声(P < 0.001)。
  • FIRST在右肝动脉的CNR最高(14.31 ± 4.17),优于其他两种方法(P < 0.05)。
  • 两名医生均将FIRST图像评为周围腹部动脉评估的最佳质量(3.0 ± 0.0,P < 0.001)。

核心结论

  • FIRST重建较FBP或AIDR 3D重建能获得更优的腹部CTA图像。

研究设计与样本

  • 对60例患者(男:女=27:33,平均年龄62.4 ± 16.7岁)的腹部CTA图像分别用FBP、AIDR 3D和FIRST三种算法重建,通过感兴趣区分析客观评估图像噪声、SNR和CNR,并由两名放射科医生独立进行主观图像质量评分。

关键影像表现/征象

  • FIRST和AIDR 3D较FBP显著降低图像噪声(P < 0.001)。
  • AIDR 3D和FIRST的SNR和CNR显著高于FBP重建(P < 0.001)。
  • FIRST在右肝动脉的CNR最高(14.31 ± 4.17),高于其他两种方法(P < 0.05)。

诊断标准与关键数值

  • 两名放射科医生基于周围动脉视觉图像质量进行评分:最佳为3分,次佳为2分,最差为1分。
  • FIRST图像在周围腹部动脉评估中被两名医生评为最佳质量(3.0 ± 0.0,P < 0.001)。

临床应用与阅片要点

  • 在腹部CTA中,FIRST重建可提供优于FBP和AIDR 3D的图像质量,尤其有利于周围腹部动脉的评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study aimed to compare the quality of abdominal CT angiography (CTA) images obtained using conventional reconstruction algorithms with those obtained using a novel iterative algorithm (forward projected model-based iterative reconstruction solution, FIRST) for evaluating arteries in the abdomen.

MATERIALS AND METHODS: Abdominal CTA images from 60 patients (M:F = 27:33; mean age, 62.4 ± 16.7 years) were reconstructed using three algorithms - filtered back projection (FBP), adaptive iterative dose reduction 3D (AIDR 3D), and FIRST. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the abdominal aorta, celiac trunk, superior mesenteric, renal, and right hepatic arteries were objectively evaluated via region-of-interest analysis and compared using the one-way analysis of variance test. Two radiologists independently scored and selected the best (score 3), second best (score 2), and the worst (score 1) images based on the visual image quality of peripheral arteries. Wilcoxon signed rank test was used for comparing image quality scores.

RESULTS: FIRST and AIDR 3D significantly reduced image noise compared with FBP (P < 0.001). SNR and CNR were significantly higher with AIDR 3D and FIRST than with FBP reconstruction (P < 0.001), with FIRST displaying the highest CNR (14.31 ± 4.17) for the right hepatic artery than the other two methods (P < 0.05). Both radiologists scored FIRST images as having the best image quality among the three methods for peripheral abdominal artery evaluation (3.0 ± 0.0, P < 0.001).

CONCLUSION: FIRST reconstruction yielded superior abdominal CTA images as compared with FBP or AIDR 3D reconstruction.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Wu R, Hori M, Onishi H, et al. Effects of reconstruction technique on the quality of abdominal CT angiography: A comparison between forward projected model-based iterative reconstruction solution (FIRST) and conventional reconstruction methods. Eur J Radiol. 2018. PMID: 30150030. doi:10.1016/j.ejrad.2018.07.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。