多回波Dixon磁共振成像无创鉴别非酒精性脂肪性肝炎与单纯性脂肪变中的肝铁含量
本研究纳入32名受试者(健康对照10名、单纯性脂肪变12名、非酒精性脂肪性肝炎10名),在3 T MRI上采用单次屏气六回波梯度回波序列测量T2*值以评估肝铁含量。非酒精性脂肪性肝炎组平均T2*值(15.49 ± 2.87 ms)显著短于单纯性脂肪变组(20.96 ± 4.28 ms,p = 0.008),以铁含量大于17.95 ms为截断值区分两者的AUC为0.908(95%CI 0.775-1.000,p = 0.001),敏感度0.833、特异度0.800。研究提示T2*计算有助于鉴别诊断非酒精性脂肪性肝炎。
要点
- 非酒精性脂肪性肝炎组T2*值15.49 ± 2.87 ms,显著短于单纯性脂肪变组20.96 ± 4.28 ms(p = 0.008)。
- 以铁含量大于17.95 ms为截断值区分非酒精性脂肪性肝炎与单纯性脂肪变,AUC为0.908(95%CI 0.775-1.000,p = 0.001)。
- 该截断值诊断敏感度0.833、特异度0.800,观察者间组内相关系数高于0.9。
核心结论
- 本研究提示T2*计算有助于鉴别诊断非酒精性脂肪性肝炎。
研究设计与样本
- 研究纳入32名受试者,分为健康对照10名、单纯性脂肪变12名和非酒精性脂肪性肝炎10名三组;所有MRI检查在3 T MRI上使用32通道体线圈完成,采用单次屏气内六回波梯度回波序列测量T2*值,并以活检证实的单纯性脂肪变和非酒精性脂肪性肝炎作为参考标准。
关键影像表现/征象
- 健康对照组平均T2*值为45.42 ± 7.19 ms,单纯性脂肪变组为20.96 ± 4.28 ms,非酒精性脂肪性肝炎组为15.49 ± 2.87 ms。
- 非酒精性脂肪性肝炎组平均T2*值显著短于单纯性脂肪变组(p = 0.008)。
- 所有肝铁含量测量的变异均未超过20%,平均变异系数为18.3%。
诊断标准与关键数值
- 以铁含量大于17.95 ms为截断值区分非酒精性脂肪性肝炎与单纯性脂肪变,AUC为0.908(95%CI 0.775-1.000,p = 0.001)。
- 该截断值的诊断敏感度为0.833,特异度为0.800。
- 观察者间组内相关系数高于0.9。
临床应用与阅片要点
- 本研究提示基于T2*弛豫测量所计算的肝铁含量可能有助于无创鉴别非酒精性脂肪性肝炎与单纯性脂肪变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The roles of iron stores in nonalcoholic fatty liver disease have not yet been clearly identified, and it is lack of uniform criteria and a standardized study design for assessing the liver iron content (LIC) in nonalcoholic steatohepatitis (NASH). This study was to compare LICs in biopsy-proven simple steatosis (SS) and NASH based on T2⁎-relaxometry.
MATERIAL AND METHODS: A total of 32 subjects divided to three groups, consisting of 10 healthy controls, 12 SS and 10 NASH. All MRI examinations were performed on a 3 T MRI with a 32-channel body coil. To measure T2⁎-value, we used a gradient echo sequence with six multiechoes within a single breath-hold. Hepatic iron contents among three groups were compared using Kruskal-Wallis H test and Mann-Whitney's posthoc tests. Diagnostic accuracy was determined by calculating the area under the receiver operating characteristics curve. To identify the reliability of iron measurements in the different region of interests, coefficient of variance (CV) was calculated overall CV values for the variability of measurements. Interobserver agreement and reliability were estimated by calculating the intraclass correlation coefficient.
RESULTS: The variations of all LIC measurements are not exceeded 20%, as a mean CV value 18.3%. intraclass correlation coefficients were higher than 0.9. Mean T2⁎-values at localized region of interests were healthy controls 45.42 ± 7.19 ms, SS 20.96 ± 4.28 ms, and NASH 15.49 ± 2.87 ms. The mean T2⁎-value in NASH is significantly shorter than that in SS (p = 0.008). The area under the receiver operating characteristics curve to distinguish NASH from SS was 0.908 (95% confidence interval 0.775-1.000, p = 0.001) at a cut-off of iron contents greater than 17.95 ms, and its diagnostic accuracy had 0.833 sensitivity and 0.800 specificity.
CONCLUSION: This study demonstrates that the T2⁎ calculation can help to differentially diagnose NASH.
引用
- Kim TH, Jeong CW, Jun HY, et al. Noninvasive Differential Diagnosis of Liver Iron Contents in Nonalcoholic Steatohepatitis and Simple Steatosis Using Multiecho Dixon Magnetic Resonance Imaging. Acad Radiol. 2018. PMID: 30143402. doi:10.1016/j.acra.2018.06.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。