成人非酒精性脂肪性肝炎临床试验中磁共振成像质子密度脂肪分数的阅片者间一致性及其纵向变化
本研究为一项胆汁酸螯合剂安慰剂对照随机临床试验的二次分析,纳入45例非酒精性脂肪性肝炎成人,在3 T下行六回波扰相梯度回波幅度脂肪定量,三名独立阅片者于基线和治疗结束时测量全肝PDFF及其纵向变化;结果显示阅片者间一致性高,27个ROI的ICC为0.998(基线)和0.998(治疗结束),9个ROI测量的一致性仅略低。
要点
- 全肝PDFF及其纵向变化的阅片者间一致性高。
- 27-ROI测量基线ICC 0.998、CV 1.8%,治疗结束ICC 0.998、CV 1.8%。
- 9-ROI测量一致性仅略低于27-ROI测量。
核心结论
- 测量全肝PDFF及其纵向变化的阅片者间一致性高,9-ROI测量的一致性仅略低于27-ROI测量。
研究设计与样本
- 安慰剂对照随机临床试验的二次分析,纳入45例非酒精性脂肪性肝炎成人,在3 T下行六回波扰相梯度回波幅度脂肪定量,三名独立阅片者于基线和治疗结束时各测量一个主要ROI和两个附加ROI。
诊断标准与关键数值
- 27-ROI测量基线ICC 0.998、CV 1.8%,治疗结束ICC 0.998、CV 1.8%,纵向变化ICC 0.997。
- 9-ROI测量基线ICC 0.997、CV 2.6%,治疗结束ICC 0.996、CV 2.4%,纵向变化ICC 0.994。
- 使用27个ROI时,阅片者间全肝PDFF偏倚幅度在基线为0.03%至0.06%点,治疗结束为0.01%至0.07%点,纵向变化为0.01%至0.02%点。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To determine the inter-reader agreement of magnetic resonance imaging proton density fat fraction (PDFF) and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis (NASH).
STUDY TYPE: We performed a secondary analysis of a placebo-controlled randomized clinical trial of a bile acid sequestrant in 45 adults with NASH. A six-echo spoiled gradient-recalled-echo magnitude-based fat quantification technique was performed at 3 T. Three independent readers measured MRI-PDFF by placing one primary and two additional regions of interest (ROIs) in each segment at both time points. Cross-sectional agreement between the three readers was evaluated using intra-class correlation coefficients (ICCs) and coefficients of variation (CV). Additionally, we used Bland-Altman analyses to examine pairwise agreement between the three readers at baseline, end of treatment (EOT), and for longitudinal change.
RESULTS: Using all ROIs by all readers, mean PDFF at baseline, at EOT, and mean change in PDFF was 16.1%, 16.0%, and 0.07%, respectively. The 27-ROI PDFF measurements had 0.998 ICC and 1.8% CV at baseline, 0.998 ICC and 1.8% CV at EOT, and 0.997 ICC for longitudinal change. The 9-ROI PDFF measurements had corresponding values of 0.997 and 2.6%, 0.996 and 2.4%, and 0.994. Using 27 ROIs, the magnitude of the bias between readers for whole-liver PDFF measurement ranged from 0.03% to 0.06% points at baseline, 0.01% to 0.07% points at EOT, and 0.01% to 0.02% points for longitudinal change.
CONCLUSION: Inter-reader agreement for measuring whole-liver PDFF and its longitudinal change is high. 9-ROI measurements have only slightly lower agreement than 27-ROI measurements.
引用
- Hooker JC, Hamilton G, Park CC, et al. Inter-reader agreement of magnetic resonance imaging proton density fat fraction and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis. Abdom Radiol (NY). 2019. PMID: 30128694. doi:10.1007/s00261-018-1745-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。