文献速递介入腹部CT

兔肿瘤模型中使用不透射线药物洗脱微球行经动脉化疗栓塞后CT图像上药物剂量分布的映射

Mapping Drug Dose Distribution on CT Images Following Transarterial Chemoembolization with Radiopaque Drug-Eluting Beads in a Rabbit Tumor Model.
PubMed 文献 · Radiology · 2018-08-14

在4只VX2肝肿瘤兔中行经动脉化疗栓塞(TACE),使用载多柔比星的不透射线药物洗脱微球(70-150微米),栓塞后1小时切除肝脏并用三维打印模具实现标本与CT图像共定位。洗脱的多柔比星在1小时后仍紧邻微球(<600微米);CT测得的微球体积和衰减与肝标本中多柔比星含量呈正线性相关(分别为0.950和0.965),基于CT的模型预测与实际肝多柔比星水平相比准确。结论认为CT可用于估算TACE后肝脏内药物剂量递送和分布。

要点

  • CT上微球体积和衰减与肝组织多柔比星含量呈正线性相关(0.950和0.965)。
  • 洗脱的多柔比星在TACE后1小时仍位于微球周围<600微米范围内。
  • 基于CT图像的模型预测与实际肝多柔比星水平相比准确。

核心结论

  • CT可能用于估算载多柔比星不透射线药物洗脱微球行TACE后肝脏内药物剂量递送和分布;作者认为该信息图可能有助于规划和理解TACE的空间效应(原文称此为推测性)。

研究设计与样本

  • 动物实验研究,兔VX2肝肿瘤模型(n=4),经动脉化疗栓塞使用载多柔比星的不透射线药物洗脱微球(70-150微米),栓塞后1小时切除肝脏并立即冷冻,用肝脏特异性三维打印模具实现肝标本与CT图像共定位,荧光显微镜评估多柔比星向微球周围组织渗透,统计模型将组织多柔比星含量与CT测得的微球体积和衰减相关联以预测多柔比星水平,并与实际测量浓度比较。

关键影像表现/征象

  • 洗脱的多柔比星在TACE后1小时仍紧邻肝内微球(<600微米)附近。
  • CT图像上测得的微球体积和衰减与肝标本中多柔比星含量呈正线性相关(分别为0.950和0.965)。
  • 基于CT图像的模型预测与实际1小时肝多柔比星水平相比准确。

诊断标准与关键数值

  • 微球体积和衰减与肝标本多柔比星含量的线性相关系数分别为0.950和0.965。
  • 多柔比星向微球周围组织渗透范围<600微米(TACE后1小时)。

临床应用与阅片要点

  • CT图像上微球体积和衰减可在兔VX2肿瘤模型中用于估算肝内多柔比星递送剂量和分布。
  • 作者认为该信息图可能有助于规划和理解药物洗脱微球TACE的空间效应(原文称此为推测性)。

局限性

  • 原文称该信息图的用途为推测性(Although speculative)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To correlate bead location and attenuation on CT images with the quantity and distribution of drug delivered to the liver following transarterial chemoembolization (TACE) with radiopaque drug-eluting beads (DEB) in a rabbit tumor model. Materials and Methods All procedures were performed with a protocol approved by the Institutional Animal Care and Use Committee. TACE was performed in rabbits (n = 4) bearing VX2 liver tumors by using radiopaque DEB (70-150 µm) loaded with doxorubicin (DOX). Livers were resected 1 hour after embolization, immediately frozen, and cut by using liver-specific three-dimensional-printed molds for colocalization of liver specimens and CT imaging. DOX penetration into tissue surrounding beads was evaluated with fluorescence microscopy. DOX levels in liver specimens were predicted by using statistical models correlating DOX content measured in tissue with bead volume and attenuation measured on CT images. Model predictions were then compared with actual measured DOX concentrations to assess the models' predictive power. Results Eluted DOX remained in close proximity (<600 µm) to beads in the liver 1 hour after TACE. Bead volume and attenuation measured on CT images demonstrated positive linear correlations (0.950 and 0.965, respectively) with DOX content in liver specimens. DOX content model predictions based on CT images were accurate compared with actual liver DOX levels at 1 hour. Conclusion CT may be used to estimate drug dose delivery and distribution in the liver following transarterial chemoembolization (TACE) with doxorubicin-loaded radiopaque drug-eluting beads (DEB). Although speculative, this informational map might be helpful in planning and understanding the spatial effects of TACE with DEB. © RSNA, 2018.