文献速递腹部MR

磁共振扩散峰度成像评估兔肝纤维化模型分期

Magnetic Resonance Diffusion Kurtosis Imaging for Evaluating Stage of Liver Fibrosis in a Rabbit Model.
PubMed 文献 · Acad Radiol · 2018-07-31

本研究纳入56只新西兰白兔,48只随机给予四氯化碳建模肝纤维化,8只给予生理盐水作为对照,在建模后第6、8、10、12周末行肝脏扩散峰度成像(DKI)后活检进行纤维化分期(F0-F4)。结果显示,随着纤维化分期从F0增至F4,FA(r=0.512)和MK(r=0.567)升高,MD(r=-0.574)降低(所有P值<0.05);MK预测分期≥F1、≥F2、≥F3及F4的AUC为0.766-0.930。结论认为DKI衍生参数有助于纤维化分期。

要点

  • 兔肝纤维化模型中,MK随纤维化分期升高而增大(r=0.567),MD随分期升高而减小(r=-0.574)。
  • MK预测纤维化分期≥F1、≥F2、≥F3和F4的AUC为0.766-0.930。
  • FA和MD可区分F0与F2,MD和MK可区分F1与F3。

核心结论

  • DKI衍生参数(MK、FA、MD)与兔肝纤维化分期相关,MK在预测纤维化分期方面表现最佳。

研究设计与样本

  • 动物实验:56只健康新西兰白兔,其中48只随机给予四氯化碳建模肝纤维化,8只给予生理盐水作为对照;所有兔在建模后第6、8、10、12周末行肝脏DKI检查后活检进行纤维化分期(F0-F4);从DKI数据衍生出平均峰度(MK)、各向异性分数(FA)和平均扩散(MD)。

诊断标准与关键数值

  • MK预测分期≥F1、≥F2、≥F3及F4的AUC为0.766-0.930;FA与分期正相关(r=0.512),MK与分期正相关(r=0.567),MD与分期负相关(r=-0.574),均P<0.05。

临床应用与阅片要点

  • 作者认为DKI衍生参数可帮助肝纤维化分期。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: As an extension of the conventional diffusion weighted imaging, diffusion kurtosis imaging (DKI) is based on the non-Gaussian diffusion model that can inherently account for restricted water diffusion within the complex microstructure of most tissues. This study aimed to investigate association of liver DKI derived parameter with stage of liver fibrosis.

MATERIALS AND METHODS: Fifty-six healthy New Zealand white rabbits were enrolled into this study, among which 48 rabbits were randomly given carbon tetrachloride to model liver fibrosis, and 8 rabbits treated with normal saline served as control subjects. All rabbits underwent liver DKI followed by biopsy to stage fibrosis (stages F0-F4) on 6th, 8th, 10th, and 12th weekends after initiation of modeling fibrosis. Mean kurtosis (MK), fractional anisotropy (FA), and mean diffusion (MD) were derived from DKI data. Statistical analysis was to evaluate association of DKI derived parameter with stage of fibrosis.

RESULTS: FA (r = 0.512) and MK (r = 0.567) increased, and MD (r = -0.574) decreased with increasing stage of fibrosis from F0 to F4 (all p values < 0.05). Significant differences were found in all parameters between F0 and F3 or F4, F1 and F4, F0 and F1-4, and F0-1 and F2-4 (all p values < 0.05). FA and MD could distinguish between F0 from F2, MD, and MK could distinguish F1 from F3, F0-2 from F3-4, and F1-2 from F3-4, and MK and FA could distinguish F2 from F4, and F0-3 from F4 (all p values < 0.05). According to receiver operating characteristic analysis, MK could best predict stage ≥F1, ≥F2, ≥F3, and F4, and discriminate F1-2 from F3-4 with areas under receiver operating characteristic curve of 0.766-0.930.

CONCLUSION: DKI derived parameters can help stage fibrosis.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Li J, Wang D, Chen TW, et al. Magnetic Resonance Diffusion Kurtosis Imaging for Evaluating Stage of Liver Fibrosis in a Rabbit Model. Acad Radiol. 2018. PMID: 30072289. doi:10.1016/j.acra.2018.06.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。