双能CT在结直肠癌患者中的应用:噪声优化虚拟单能成像改善低密度肝转移瘤评估
回顾性纳入53例经组织学证实的结直肠癌低密度肝转移患者,行腹部双能CT并重建标准线性融合M_0.6、传统虚拟单能图像(VMI)及噪声优化VMI+(40–100 keV,每10 keV递增)。定量参数在40 keV VMI+达峰值(SNR 8.1±3.4,CNR 6.5±2.6),主观图像质量最佳评分为60 keV VMI+(中位数5分),病灶 delineation 最佳为40 keV VMI+(中位数5分),均显著优于标准重建及所有传统VMI序列(P≤0.001)。
要点
- 40 keV VMI+的SNR和CNR达峰值,定量图像质量优于标准重建和传统VMI。
- 60 keV VMI+的主观图像质量评分最高(中位数5分)。
- 40 keV VMI+对低密度肝转移瘤的病灶 delineation 最佳(中位数5分)。
核心结论
- 低 keV VMI+重建较标准重建和传统VMI序列显著提高结直肠癌低密度肝转移患者的定量和定性图像质量参数;40 keV VMI+可获得最佳病灶 delineation。
研究设计与样本
- 经IRB批准的回顾性研究,连续纳入53例经组织学证实的结直肠癌低密度肝转移患者(平均年龄70.3±11.4岁,范围44–86岁),行腹部双能CT,重建标准线性融合M_0.6、传统VMI及噪声优化VMI+序列(40–100 keV,每10 keV递增)。
关键影像表现/征象
- VMI+序列在40 keV时定量图像质量参数达峰值(SNR 8.1±3.4,CNR 6.5±2.6)。
- 60 keV VMI+序列的主观图像质量评分最高(中位数5分)。
- 40 keV VMI+序列对病灶 delineation 的评分显著优于所有其他重建(中位数5分)。
诊断标准与关键数值
- 定量参数:40 keV VMI+的SNR 8.1±3.4、CNR 6.5±2.6,与标准重建及所有传统VMI序列差异有统计学意义(P≤0.001)。
- 主观图像质量:60 keV VMI+评分中位数5分,与线性融合M_0.6及所有传统VMI序列差异有统计学意义(P≤0.001)。
- 病灶 delineation:40 keV VMI+评分中位数5分,显著优于所有其他重建(P≤0.001)。
临床应用与阅片要点
- 低 keV VMI+(40 keV)可提高低密度肝转移瘤的SNR和CNR,有助于病灶 delineation。
- 60 keV VMI+在主观图像质量上评分最高,可用于兼顾图像噪声与病灶显示。
- 主观评分采用五点Likert量表,由三名盲法放射科医师完成。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the value of the noise-optimized virtual monoenergetic imaging (VMI+) technique on quantitative and qualitative image parameters in patients with hypoattenuating liver metastases from colorectal cancer (CRC) at abdominal dual-energy CT (DECT).
MATERIALS AND METHODS: Fifty-three consecutive patients (mean age, 70.3 ± 11.4 years; range, 44-86 years) with histologically proven, hypoattenuating liver metastases from CRC were retrospectively included in this IRB-approved study. DECT datasets were reconstructed as standard linearly-blended M_0.6 image series, traditional virtual monoenergetic images (VMI), and noise-optimized VMI+ series. VMI and VMI+ reconstructions were obtained at energy levels ranging from 40 to 100-keV with 10-keV increments. Signal attenuation of liver parenchyma and liver metastases was measured to calculate signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Each image series was subjectively rated by three blinded radiologists with regard to image quality, lesion delineation, and image noise using a five-point Likert scale.
RESULTS: Quantitative image quality parameters peaked at 40-keV VMI+ (SNR, 8.1 ± 3.4; CNR, 6.5 ± 2.6) with statistically significant differences in comparison with standard reconstructions and all traditional VMI series (P ≤ 0.001). Qualitative image analysis revealed best rating scores for 60-keV VMI+ series (median, 5) with significant differences compared to linearly-blended M_0.6 and all traditional VMI series (P ≤ 0.001). Lesion delineation showed significantly superior ratings for 40-keV VMI+ series compared to all other reconstructions (median, 5) (P ≤ 0.001).
CONCLUSION: Low-keV VMI+ reconstructions demonstrate significantly increased quantitative and qualitative image quality parameters in patients with hypoattenuating liver metastases from CRC in comparison with standard reconstructions and traditional VMI series at abdominal DECT. Best lesion delineation can be achieved at 40-keV VMI+.
引用
- Lenga L, Czwikla R, Wichmann JL, et al. Dual-energy CT in patients with colorectal cancer: Improved assessment of hypoattenuating liver metastases using noise-optimized virtual monoenergetic imaging. Eur J Radiol. 2018. PMID: 30150043. doi:10.1016/j.ejrad.2018.07.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。