B型图像引导的超声衰减参数可准确检测慢性肝病中的肝脂肪变性

The B-Mode Image-Guided Ultrasound Attenuation Parameter Accurately Detects Hepatic Steatosis in Chronic Liver Disease.
PubMed 文献 · Ultrasound Med Biol · 2018-08-02

该前瞻性研究纳入163例慢性肝病患者,同日行超声引导衰减参数(UGAP)、受控衰减参数(CAP)、CT和肝活检,以组织病理学为参考标准。UGAP诊断≥S1、≥S2、≥S3的AUC分别为0.900、0.953、0.959,对≥S2和≥S3的识别显著优于CAP。结论认为UGAP对慢性肝病患者肝脂肪变性具有高诊断准确性。

要点

  • UGAP诊断≥S1、≥S2、≥S3的AUC分别为0.900、0.953、0.959。
  • UGAP对≥S2和≥S3的识别显著优于CAP。
  • 衰减系数与脂肪变百分比、CAP值及肝脾CT衰减比显著相关(p < 0.001)。

核心结论

  • UGAP对慢性肝病患者肝脂肪变性具有高诊断准确性,对≥S2和≥S3的识别显著优于CAP。

研究设计与样本

  • 前瞻性分析163例连续慢性肝病患者,2016年4月至2017年7月间同日行UGAP、CAP、CT和肝活检,以组织病理学为参考标准。

诊断标准与关键数值

  • UGAP诊断≥S1的AUC为0.900,≥S2为0.953,≥S3为0.959。
  • UGAP对≥S2和≥S3的识别显著优于CAP。
  • S0(n = 62)、S1(n = 63)、S2(n = 23)、S3(n = 15)级患者的中位衰减系数值分别为0.485、0.560、0.660、0.720。
  • 衰减系数与脂肪变百分比、CAP值及肝脾CT衰减比显著相关(p < 0.001)。

临床应用与阅片要点

  • 作者结论认为UGAP对慢性肝病患者肝脂肪变性具有高诊断准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The purpose of our study was to evaluate the diagnostic accuracy of the ultrasound-guided attenuation parameter (UGAP) for the detection of hepatic steatosis in comparison with the controlled attenuation parameter (CAP), using histopathology as the reference standard. We prospectively analyzed 163 consecutive chronic liver disease patients who underwent UGAP, CAP, computed tomography and a liver biopsy on the same day between April 2016 and July 2017. Radiofrequency signals corresponding to the images were compensated by the reference signal previously measured from the uniform phantom with known attenuation (0.44 dB/cm/MHz). The attenuation coefficient was calculated from the signals' decay slope. The median attenuation coefficient values in patients with S0 (n = 62), S1 (n = 63), S2 (n = 23) and S3 grade (n = 15) were 0.485, 0.560, 0.660 and 0.720, respectively. Significant correlations were found between attenuation coefficient and percentage steatosis, CAP values and liver-to-spleen computed tomography attenuation ratio (p < 0.001). The areas under the receiver operating characteristic curve of UGAP for identifying ≥S1, ≥S2 and ≥S3 were 0.900, 0.953 and 0.959, respectively, which were significantly better than the results obtained with CAP for identifying ≥S2 and ≥S3. In conclusion, UGAP had high diagnostic accuracy for detecting hepatic steatosis in patients with chronic liver disease.