肝肿瘤患者肝实质硬度的评估:剪切波弹性成像的最佳策略

Evaluation of liver parenchyma stiffness in patients with liver tumours: optimal strategy for shear wave elastography.
PubMed 文献 · Eur Radiol · 2018-08-13

127例肝肿瘤患者术前接受二维剪切波弹性成像,测量肝距肿瘤边缘0-1 cm、1-2 cm和>2 cm处及脾的硬度。距肿瘤边缘>2 cm处肝硬度诊断肝硬化的AUC为0.940,优于更近处测量和脾硬度;结论认为肝硬度应在距肿瘤边缘>2 cm处测量。

要点

  • 肝肿瘤患者背景肝硬度应在距肿瘤边缘>2 cm处测量。
  • 距肿瘤边缘>2 cm处肝硬度诊断肝硬化AUC为0.940,特异度90.3%。
  • 无可用肝组织检测时,脾硬度测量可作为肝硬度测量的替代。

核心结论

  • 肝肿瘤患者肝硬度最佳测量位置为距肿瘤边缘>2 cm处;无可用肝组织检测时,脾硬度测量可作为肝硬度测量的替代。

研究设计与样本

  • 127例肝肿瘤患者术前接受二维剪切波弹性成像,测量肝距肿瘤边缘0-1 cm(PLS-1)、1-2 cm(PLS-2)、>2 cm(RLS)处硬度及脾硬度(SS),以受试者工作特征曲线下面积(AUC)分析各值诊断肝硬化的效能。

关键影像表现/征象

  • PLS-1高于PLS-2,PLS-2高于RLS(p < 0.001)。
  • 肿瘤大小、位置或类型对二维剪切波弹性成像值无明显影响,但RLS在原发性肝癌患者中更高(p < 0.05)。

诊断标准与关键数值

  • PLS-1、PLS-2、RLS和SS诊断肝硬化的AUC分别为0.760、0.833、0.940和0.676,特异度分别为75.7%、67.6%、90.3%和77.4%。

临床应用与阅片要点

  • 肝肿瘤患者评估背景肝硬度时,应在距肿瘤边缘>2 cm处测量。
  • 无可用肝组织检测时,可测量脾硬度作为肝硬度测量的替代。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the methodology of non-invasive test for evaluation of liver stiffness (LS) with tumours using two-dimensional (2D) shear wave elastography (SWE).

METHODS: One hundred and twenty-seven patients with liver tumours underwent 2D-SWE before surgery to measure liver and spleen stiffness (SS). Two-dimensional SWE values were obtained in the liver at 0-1 cm, 1-2 cm and >2 cm from the tumour edge (PLS-1, PLS-2 and RLS, respectively). The influence of tumour-associated factors was evaluated. The area under the receiver operating characteristic curve (AUC) for each value was analysed to diagnose cirrhosis.

RESULTS: PLS-1 was higher than PLS-2, which was even higher than RLS (p < 0.001). The AUCs of PLS-1, PLS-2, RLS and SS for diagnosing cirrhosis were 0.760, 0.833, 0.940 and 0.676, with the specificity of 75.7%, 67.6%, 90.3% and 77.4%, respectively. Tumour sizes, locations or types showed no apparent influence on 2D-SWE values except for RLS, which was higher in patients with primary hepatic carcinomas (p < 0.05).

CONCLUSIONS: LS with tumours is best measured at >2 cm away from the tumour edge. SS measurement could be used as an alternative to LS measurement in the event of no available liver for detection.

KEY POINTS: • Tumour-associated factors impact background liver stiffness assessment. • Background liver stiffness is best measured at >2 cm from tumour edge. • Spleen stiffness can be an alternative to assess background liver stiffness.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zheng W, Zhou ZG, Wong CH, et al. Evaluation of liver parenchyma stiffness in patients with liver tumours: optimal strategy for shear wave elastography. Eur Radiol. 2018. PMID: 30105408. doi:10.1007/s00330-018-5676-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。