文献速递腹部MR

肝移植术后胆道并发症:3T设备下MR胰胆管成像与MR成像的评估

Biliary complications after liver transplantation: Assessment with MR cholangiopancreatography and MR imaging at 3T device.
PubMed 文献 · Eur J Radiol · 2018-07-11

回顾性分析232例肝移植受者共384次3T MR检查,以直接胆管造影、手术及临床随访为参考标准,评估MRCP与MR成像诊断胆道并发症的效能,其敏感度99%、特异度96%、诊断准确率97%。

要点

  • 3T MRCP联合MR成像对肝移植术后胆道并发症诊断敏感度99%、特异度96%。
  • 最常见的胆道并发症为非吻合口狭窄(含缺血型胆道病变67例)和结石/胆泥/管型(65例)。
  • MRCP序列包括冠状薄层3D-FRFSE和冠状斜厚层SSFSE T2w,可多方位显示胆道。

核心结论

  • 3T设备下MRCP与MR成像对检测肝移植术后胆道并发症极为可靠。

研究设计与样本

  • 回顾性分析232例肝移植受者共384次MR检查,所有受者均因肝功能异常和/或超声发现胆道异常而怀疑胆道并发症。
  • 采用3T设备(GE-DISCOVERY MR750;GE Healthcare),序列包括轴位3D双回波T1w、T2w(propeller和SS-FSE)、冠状薄层3D-FRFSE和冠状斜厚层SSFSE T2w的MRCP、多b值(150、500、1000、1500 s/mm2)全方向DWI,25/232例加做增强MRCP。
  • 由两名经验丰富的腹部放射科医师盲法共识评估,最终诊断基于直接胆管造影、手术及结合超声和/或MRI的临床随访。

关键影像表现/征象

  • 113例未见胆道异常,119例存在一种或多种并发症:非吻合口狭窄包括典型缺血型胆道病变67例、吻合口狭窄34例、壶腹功能障碍4例、吻合口漏4例、结石/胆泥/管型65例、胆管消失1例。

诊断标准与关键数值

  • 评估者检测所有类型胆道并发症的敏感度99%、特异度96%、PPV 95%、NPV 99%、诊断准确率97%。

临床应用与阅片要点

  • 对肝移植术后怀疑胆道并发症者,可行3T MRCP联合MR成像评估胆道狭窄、漏、结石及胆管消失等并发症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Our study was aimed to assess the diagnostic value of MR cholangiopancreatography (MRCP) and MR imaging at 3 T device when evaluating biliary adverse events after liver transplantation.

MATERIALS AND METHODS: A series of 384 MR examinations in 232 liver transplant subjects with suspected biliary complications (impaired liver function tests and/or biliary abnormalities on ultrasound) were performed at 3 T device (GE-DISCOVERY MR750; GE Healthcare). After the acquisition of axial 3D dual-echo T1-weighted images and T2-weighted sequences (propeller and SS-FSE), MRCP was performed through coronal thin-slab 3D-FRFSE and coronal oblique thick-slab SSFSE T2w sequences. DW-MRI of the liver was performed using an axial spin-echo echo-planar sequence with multiple b values (150, 500, 1000, 1500 s/mm2) in all diffusion directions. Contrast-enhanced MRCP was performed in 25/232 patients. All MR images were blindly evaluated by two experienced abdominal radiologists in consensus to determine the presence of biliary complications, whose final diagnosis was based on direct cholangiography, surgery and integrating clinical follow-up with ultrasound and/or MRI findings.

RESULTS: In 113 patients no biliary abnormality was observed. The remaining 119 subjects were affected by one or more of the following complications: non-anastomotic strictures including typical ischemic-type biliary lesions (n = 67), anastomotic strictures (n = 34), ampullary dysfunction (n = 4), anastomotic leakage (n = 4), stones, sludge and casts (n = 65), vanishing bile duct (n = 1). The sensitivity, specificity, PPV, NPV and diagnostic accuracy of the reviewers for the detection of all types of biliary complications were 99%, 96%, 95%, 99% and 97%, respectively.

CONCLUSION: MR cholangiopancreatography and MR imaging at 3 T device are extremely reliable for detecting biliary complications after liver transplantation.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Boraschi P, Donati F, Pacciardi F, et al. Biliary complications after liver transplantation: Assessment with MR cholangiopancreatography and MR imaging at 3T device. Eur J Radiol. 2018. PMID: 30150050. doi:10.1016/j.ejrad.2018.07.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。