双能CT鉴别非穿孔性坏疽性阑尾炎与无并发症阑尾炎
本回顾性研究纳入209例经病理诊断的阑尾炎患者,由两名腹部放射科医师评估120kV模拟图像、40keV虚拟单能图像和彩色碘覆盖图像。坏疽性阑尾炎44例(21.0%);40keV虚拟单能图像敏感度100%、特异度81.2%、准确率85.2%,碘覆盖图像分别为100%、80.0%、84.2%,120kV模拟图像敏感度仅22.7%。结论认为双能CT虚拟单能和碘覆盖成像能高敏感度、高特异度地确认和排除坏疽性阑尾炎。
要点
- 40keV虚拟单能图像诊断坏疽性阑尾炎敏感度100%(44/44),特异度81.2%(134/165)。
- 碘覆盖图像敏感度100%(44/44),特异度80.0%(132/165),与虚拟单能图像接近。
- 120kV模拟图像敏感度仅22.7%(10/44),特异度96.4%(159/165),易漏诊坏疽。
核心结论
- 在疑似阑尾炎病例中,包含虚拟单能成像和碘覆盖成像的双能CT能以高敏感度和高特异度确认和排除坏疽性阑尾炎。
研究设计与样本
- 回顾性研究,纳入209例经病理诊断为阑尾炎的患者;由两名委员会认证的腹部放射科医师阅片,评估120kV模拟图像、40keV虚拟单能图像和彩色碘覆盖图像。
关键影像表现/征象
- 坏疽性阑尾炎44例(21.0%),病理结果阳性。
- 40keV虚拟单能图像和碘覆盖图像对所有坏疽性阑尾炎病例均为真阳性,无假阴性结果。
诊断标准与关键数值
- 40keV虚拟单能图像:敏感度100%(44/44),特异度81.2%(134/165),阳性预测值58.7%(44/75),阴性预测值100%(134/134),准确率85.2%,观察者间一致性0.99。
- 碘覆盖图像:敏感度100%(44/44),特异度80.0%(132/165),阳性预测值57.1%(44/77),阴性预测值100%(132/132),准确率84.2%,观察者间一致性0.99。
- 120kV模拟图像:敏感度22.7%(10/44),特异度96.4%(159/165),阳性预测值62.5%(10/16),阴性预测值82.4%(159/193),准确率77.5%,观察者间一致性0.93。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The hypothesis of this study was that the use of dual-energy spectral techniques in CT can improve accuracy in the diagnosis of acute gangrenous appendicitis.
MATERIALS AND METHODS: This retrospective study included 209 patients with a pathologic diagnosis of appendicitis. Two board-certified abdominal radiologists reviewed 120-kV simulated images, 40-keV virtual monoenergetic images, and color-coded iodine overlay images. Sensitivity, specificity, positive and negative predictive values (PPV and NPV), accuracy, and interobserver agreement were calculated for each set of images.
RESULTS: Forty-four patients (21.0%) had histopathologic results positive for gangrenous appendicitis. The sensitivity of 40-kV virtual monoenergetic imaging was 100% (44/44); specificity, 81.2% (134/165); PPV, 58.7% (44/75); NPV, 100% (134/134); accuracy, 85.2%; and interobserver agreement, 0.99. The corresponding values for the iodine overlay imaging datasets were 100% (44/44), 80.0% (132/165), 57.1% (44/77), 100% (132/132), 84.2%, and 0.99 and for 120-kV simulated imaging were 22.7% (10/44), 96.4% (159/165), 62.5% (10/16), 82.4% (159/193), 77.5%, and 0.93. All cases of gangrenous appendicitis had true-positive results of virtual monoenergetic and iodine overlay imaging. There were no false-negative results of virtual monoenergetic or iodine overlay imaging.
CONCLUSION: In cases of suspected appendicitis, dual-energy CT that includes virtual monoenergetic and iodine overlay imaging is accurate for confirming and excluding the presence of gangrenous appendicitis with high sensitivity and specificity.
引用
- Elbanna KY, Mohammed MF, Chahal T, et al. Dual-Energy CT in Differentiating Nonperforated Gangrenous Appendicitis From Uncomplicated Appendicitis. AJR Am J Roentgenol. 2018. PMID: 30063397. doi:10.2214/AJR.17.19274
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。