16厘米宽探测器CT行冠状动脉CT血管造影时缩短注射时间降低对比剂剂量
前瞻性随机将106例行16厘米宽探测器CT冠状动脉CT血管造影的患者分为A组(n=50,注射时间8秒)和B组(n=56,标准10秒),对比剂按25 mgI/kg/s的剂量率给予。A组总对比剂剂量36.2±5.7 ml显著低于B组46.4±6.3 ml(p<0.001),两组注射速率和强化持续时间无差异(p>0.05),各主要冠状动脉CT值及主观图像质量评分均无差异(均p>0.05)。结论认为缩短注射至8秒可行,能显著降低对比剂剂量、维持 adequate 强化并减少对比剂相关伪影。
要点
- A组对比剂剂量36.2±5.7 ml显著低于B组46.4±6.3 ml(p<0.001)。
- 两组注射速率及强化持续时间无差异(p>0.05)。
- 两组各主要冠状动脉CT值及主观图像质量评分无差异(均p>0.05)。
核心结论
- 在16厘米宽探测器CT系统上行CCTA时,将对比剂注射时间缩短至8秒并延迟触发可行,能显著降低对比剂剂量、维持血管 adequate 强化并减少对比剂相关伪影。
研究设计与样本
- 前瞻性随机研究,共纳入106例行16厘米宽探测器CT冠状动脉CT血管造影的患者,随机分为A组(n=50,注射时间8秒)和B组(n=56,标准注射时间10秒);使用体重依赖的对比剂碘帕醇(Iopamiro,370 mgI/ml),剂量率25 mgI/kg/s。
诊断标准与关键数值
- A组总对比剂剂量36.2±5.7 ml显著低于B组46.4±6.3 ml(p<0.001)。
- 两组注射速率和强化持续时间无差异(p>0.05)。
- 两组所有主要冠状动脉CT值无差异(p>0.05)。
- 两组主观图像质量评分无差异(均p>0.05)。
临床应用与阅片要点
- 在16厘米宽探测器CT系统上行CCTA时,可采用8秒缩短注射时间联合延迟触发方案以降低对比剂剂量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES:: To investigate the use of shortened contrast injection with late triggering in coronary CT angiography (CCTA) for decreasing contrast dose and maintaining image quality.
METHODS:: 106 patients for CCTA on a 16-cm wide-detector CT were prospectively enrolled into groups A (n = 50) and B (n = 56) randomly. Patient weight-dependent contrast medium (Iopamiro, 370 mgI ml-1) at dose rate of 25 mgI/kg/s was used with 8 s and the standard 10 s injection time in groups A and B, respectively. CT values of the aortic sinus (AS), right coronary artery, left anterior descending and left circumflex at the proximal, middle and distal segments were measured and compared. Subjective image quality was evaluated and analyzed with Fisher exact test. Contrast dose, injection rate and enhancement duration (between the start of enhancement in AS and scan finish) were also compared.
RESULTS:: There was no difference in the injection rate and enhancement duration between the two groups (p > 0.05), while the total contrast dose in group A (36.2 ± 5.7 ml) was significantly lower than in group B (46.4 ± 6.3 ml) (p < 0.001). There was no difference for CT values in all major coronary vessels between the two groups and no difference in subjective image quality scores (all p > 0.05).
CONCLUSION:: It is feasible to shorten contrast injection to 8 s in CCTA on wide-detector CT systems to significantly reduce contrast dosage, maintain adequate enhancement and reduce contrast-related artifacts.
ADVANCES IN KNOWLEDGE:: (1) Coronary CT angiography (CCTA) scans with shortened contrast medium injection duration and late triggering are feasible with a 16-cm wide-detector CT system (2) Compared with the conventional CCTA with 10 s contrast injection duration, the new contrast injection protocol of using shortened injection duration (to 8 s) and late triggering reduces contrast dose to 36.2 ml, while maintaining adequate enhancement in vessels and reducing contrast-related artifacts.
引用
- Qu TT, Li JY, Jiao XJ, et al. Contrast dose reduction with shortened injection durations in coronary CT angiography on 16-cm Wide-detector CT scanner. Br J Radiol. 2018. PMID: 30160183. doi:10.1259/bjr.20180580
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。