心房颤动患者低剂量冠状动脉CT血管成像:两种技术方法的图像质量与辐射暴露比较
研究纳入105例慢性心房颤动患者,随机分为双采集方案组(50例)与单采集方案组(50例),采用全心脏覆盖高清晰度CT扫描仪行冠状动脉CT血管成像。单采集方案组整体图像质量与双采集方案组相当,冠状动脉可判读性相似,而有效剂量显著低于双采集方案组。
要点
- 单采集方案组有效剂量2.7±0.7 mSv,显著低于双采集方案组5.3±1.8 mSv(p<0.001)。
- 两组图像质量Likert评分分别为3.3±1.2与3.2±1.4(p=ns),冠状动脉可判读性分别为97.5%与97.1%(p=ns)。
- 扫描期间平均心率双采集方案组85.6±21 bpm,单采集方案组83.7±23 bpm(p<ns)。
核心结论
- 新型全心脏覆盖CT扫描仪使心房颤动患者可采用单采集方案行冠状动脉CT血管成像,图像质量高且辐射暴露低。
研究设计与样本
- 随机对照研究,纳入105例连续慢性心房颤动患者,排除5例肾功能受损者后,双采集方案组50例与单采集方案组50例;采用全心脏覆盖高清晰度CT扫描仪(16 cm z轴覆盖、256排探测器、0.28秒机架旋转时间)。
诊断标准与关键数值
- 图像质量采用Likert量表评分,双采集方案组3.3±1.2、单采集方案组3.2±1.4(p=ns);冠状动脉可判读性双采集方案组97.5%、单采集方案组97.1%(p=ns);有效剂量双采集方案组5.3±1.8 mSv、单采集方案组2.7±0.7 mSv(p<0.001)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To evaluate image quality, coronary interpretability and radiation exposure of coronary CT angiography (CCTA) performed in patients with atrial fibrillation (AF) with the latest scanner generation, comparing two different technical approaches. A new scanner that combines a 0.23 mm spatial resolution, a new generation of iterative reconstruction, fast gantry rotation time and the intracycle motion-correction algorithm to improve the temporal resolution was recently introduced in the clinical field.
MATERIALS AND METHODS: We enrolled 105 consecutive patients with chronic AF who performed CCTA with a whole-heart coverage high-definition CT scanner (16-cm z-axis coverage with 256 detector rows, 0.28 s gantry rotation time). Five of them were excluded for impaired renal function. Patients were randomized between a double acquisition protocol (50 patients, group 1) or a single acquisition protocol (50 patients, group 2). The image quality, coronary segment interpretability and effective dose (ED) of CCTA were assessed.
RESULTS: The mean HR during the scan was 85.6±21 bpm in group 1 vs. 83.7±23 bpm in Group 2, respectively (p < ns). In group 2, overall image quality was high and comparable with that of group 1 (Likert scale =3.2 ± 1.4 vs. 3.3 ± 1.2, p = ns, in group 1 and 2, respectively). Coronary interpretability was high and similar between the two groups (97.5% and 97.1% in group 1 and 2, p = ns, respectively). Mean ED was significantly higher in group 1 than in group 2 (5.3 ± 1.8 mSv vs. 2.7 ± 0.7 mSv, p < 0.001).
CONCLUSION: The novel whole-heart coverage CT scanner allows to perform CCTA with a single-acquisition protocol with high image quality and low radiation exposure in AF patients.
引用
- Mushtaq S, Pontone G, Conte E, et al. Low-Dose Coronary CT Angiography in Patients with Atrial Fibrillation: Comparison of Image Quality and Radiation Exposure with Two Different Approaches. Acad Radiol. 2018. PMID: 30093216. doi:10.1016/j.acra.2018.07.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。