文献速递心血管外周血管胸部CTDSA

经导管主动脉瓣置换术前CT检查采用低碘对比剂注射方案:主动脉评估与冠状动脉疾病筛查

Low Iodine Contrast Injection for CT Acquisition Prior to Transcatheter Aortic Valve Replacement: Aorta Assessment and Screening for Coronary Artery Disease.
PubMed 文献 · Acad Radiol · 2018-08-01

研究纳入84例经导管主动脉瓣置换术前患者,42例采用标准碘注射方案(120 mL),42例采用低剂量碘注射方案(60 mL)。标准方案升主动脉平均衰减显著更高,但两组图像质量、冠状动脉诊断图像质量及基于冠状动脉造影的冠状动脉疾病诊断敏感度、特异度、预测值和准确率均无显著差异。

要点

  • 低碘方案(60 mL)与标准方案(120 mL)的冠状动脉图像诊断质量分别为96.5%与94.6%,无显著差异。
  • 低碘方案显示冠状动脉疾病的敏感度、特异度、阴性预测值、阳性预测值和准确率分别为100%、86%、87%、100%和93%。
  • 标准方案升主动脉平均衰减显著高于低碘方案,但主动脉瓣、升主动脉和腹主动脉图像质量无显著差异。

核心结论

  • 尽管主动脉平均衰减存在差异,低碘注射方案在图像质量和冠状动脉疾病检出方面与标准注射方案相似。

研究设计与样本

  • 研究纳入84例经导管主动脉瓣置换术前患者,42例采用标准碘注射方案(120 mL),42例采用低剂量碘注射方案(60 mL),以冠状动脉造影为参考标准计算冠状动脉疾病的诊断效能。

关键影像表现/征象

  • 标准方案(P1)升主动脉平均衰减显著高于低碘方案(P2)(p < 0.001)。
  • 主动脉瓣、升主动脉和腹主动脉图像质量在两组间无显著差异(p = 0.876;p = 0.306;p = 1.0)。

诊断标准与关键数值

  • 冠状动脉诊断图像质量优良率:标准方案94.6% vs 低碘方案96.5%(p = 0.08)。
  • 冠状动脉疾病诊断敏感度:标准方案100% vs 低碘方案100%(p = 0.93)。
  • 冠状动脉疾病诊断特异度:标准方案79% vs 低碘方案86%(p = 0.58)。
  • 冠状动脉疾病诊断阴性预测值:标准方案70% vs 低碘方案87%(p = 0.90);阳性预测值:标准方案100% vs 低碘方案100%(p = 1.0)。
  • 冠状动脉疾病诊断准确率:标准方案86% vs 低碘方案93%(p = 0.74)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To assess both the complete aorta and coronary artery disease (CAD) using low iodine contrast computed-tomography angiography before transcatheter aortic valve replacement.

MATERIALS AND METHODS: 84 patients underwent computed-tomography angiography before transcatheter aortic valve replacement: 42 with standard iodine injection protocol (P1:120 mL); 42 with a low dose iodine injection protocol (P2:60 mL). Mean attenuation and subjective image quality were rated at different levels of the aorta, iliac and coronary arteries. Sensitivity, specificity, negative and positive predictive values for depiction of CAD were calculated according to the coronary angiography.

RESULTS: Mean attenuation was significantly higher in P1 for the ascending aorta (p < 0.001). No significant difference was observed regarding image quality of the aortic valve (p = 0.876), the ascending aorta (p = 0.306), or the abdominal aorta (p = 1.0). Diagnostic image quality of coronary arteries was excellent for P1 and P2 (94.6% vs 96.5%, p = 0.08). Sensitivity, specificity, negative and positive predictive values, and accuracy for depiction of CAD were excellent for P1 and P2 (100% vs 100%; 79% vs 86%, 70% vs 87%, 100% vs 100% and 86% vs 93%) without significant differences (p = 0.93; p = 0.58; p = 0.90; p = 1.0; p = 0.74), respectively.

CONCLUSION: Despite a difference in aortic mean attenuation, a reduced iodine injection protocol showed similar image quality and detection of CAD in comparison with a standard injection protocol.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Hachulla AL, Noble S, Ronot M, et al. Low Iodine Contrast Injection for CT Acquisition Prior to Transcatheter Aortic Valve Replacement: Aorta Assessment and Screening for Coronary Artery Disease. Acad Radiol. 2018. PMID: 30076081. doi:10.1016/j.acra.2018.06.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。