早孕期静脉导管流速比值作为主要心脏缺陷标志物的研究
本研究回顾性分析480例解剖正常胎儿与48例主要心脏缺陷胎儿的早孕期静脉导管血流,评估a波定性、PIV及流速比值。心脏缺陷组a波反向和PIV高于第95百分位者均为26例(54.2%),a/S或a/D比值低于第5百分位对心脏异常的检出率为62.5%,优于PIV的54.2%。作者认为a/S比值在5%假阳性率下可检出约60%的先天性心脏缺陷。
要点
- 心脏缺陷胎儿中a/S或a/D比值低于第5百分位者检出率达62.5%,高于PIV的54.2%。
- 心脏缺陷组a波反向和PIV高于第95百分位者均为26例(54.2%)。
- 正常组a波反向15例(3.1%),PIV高于第95百分位25例(5.2%)。
核心结论
- 早孕期a/S比值在5%假阳性率下可检出约60%的先天性心脏缺陷,优于静脉导管搏动指数。
研究设计与样本
- 回顾性研究,纳入2010–2017年图宾根大学和2013–2016年科隆大学的单胎早孕期超声筛查病例,正常胎儿与主要心脏缺陷胎儿比例为10:1,共480例正常和48例缺陷胎儿。
关键影像表现/征象
- 心脏缺陷组a波反向和PIV高于第95百分位者均为26例(54.2%)。
- 正常组a波反向15例(3.1%),PIV高于第95百分位25例(5.2%)。
- 多数心脏缺陷与a/S或a/D比值异常相关。
诊断标准与关键数值
- a/S或a/D比值 cutoff 设为正常分布第5百分位时,胎儿心脏异常检出率为62.5%。
- 同一阈值下DV-PIV检出26例(54.2%)缺陷胎儿。
- 正常组和缺陷组中位颈项透明层分别为1.9 mm和2.6 mm,颈项透明层厚度高于第99百分位者分别有5例(1.0%)和18例(37.5%)。
临床应用与阅片要点
- 早孕期评估静脉导管血流时,除PIV和a波外,可测量a/S或a/D流速比值。
- a/S或a/D比值低于正常分布第5百分位提示心脏缺陷风险增高。
局限性
- 本研究为回顾性研究。
- 作者结论指出a/S比值有潜力检出约60%的先天性心脏缺陷,需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To examine ductus venosus (DV) flow in fetuses with and those without a cardiac defect and to evaluate different phases of DV flow in addition to the standard assessment of DV pulsatility index for veins (PIV) and the a-wave.
METHODS: This was a retrospective study of singleton pregnancies that underwent first-trimester ultrasound screening, which included DV flow assessment, at the University of Tübingen (between 2010 and 2017) or the University of Cologne (between 2013 and 2016). The study population comprised normal fetuses and fetuses with major cardiac defects at a ratio of 10:1. For each fetus, the following parameters of the DV waveform were evaluated: qualitative assessment of the a-wave, PIV measurement and ratios of flow velocities during the S-wave (S) or D-wave (D) and the a-wave (a) or v-wave (v). Reproducibility of DV-PIV and DV flow ratios was evaluated in 30 fetuses in which the DV flow was assessed twice.
RESULTS: Our study population included 480 anatomically normal fetuses and 48 with a cardiac defect. Median fetal nuchal translucency (NT) in the normal and in the affected group was 1.9 mm and 2.6 mm, respectively. In five (1.0%) of the normal and 18 (37.5%) of the affected cases, fetal NT thickness was above the 99th centile. In the normal group, the DV a-wave was reversed in 15 (3.1%) cases and the DV-PIV was above the 95th centile in 25 (5.2%). In the cases with cardiac defects, the a-wave was reversed and the DV-PIV measurement was above the 95th centile in 26 (54.2%). The reproducibility of measurement of the ratios of DV flow velocities was similar to that of the DV-PIV. Most cardiac defects were associated with an abnormal a/S or a/D ratio. If the cut-off for these two ratios was set at the 5th centile of the normal distribution, the detection rate of fetal cardiac anomalies would be 62.5%. This compares favorably with the DV-PIV, which detects 26 (54.2%) of the affected fetuses for the same threshold.
CONCLUSION: In the first trimester, the a/S ratio has the potential to detect approximately 60% of congenital cardiac defects for a false-positive rate of 5%. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.
引用
- Wagner P, Eberle K, Sonek J, et al. First-trimester ductus venosus velocity ratio as a marker of major cardiac defects. Ultrasound Obstet Gynecol. 2019. PMID: 30125415. doi:10.1002/uog.20099
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。