文献速递心血管MR

T1与T2 mapping在识别非ST段抬高型心肌梗死患者急性心肌损伤中的应用

T1 and T2 mapping in the identification of acute myocardial injury in patients with NSTEMI.
PubMed 文献 · Radiol Med · 2018-08-21

研究纳入47例急性NSTEMI患者,在血运重建前于1.5 T行心脏磁共振T1与T2 mapping检查;梗死心肌T1、T2值均显著高于远程心肌(p<0.0001);T1/T2 mapping可检出无显著冠脉狭窄患者的心肌水肿,反之亦然,提示冠脉造影与CMR水肿成像在NSTEMI评估中可能提供互补信息。

要点

  • 梗死心肌T1值1151.6±53.5 ms、T2值69±6 ms,均显著高于远程心肌的958.2±38.6 ms与51.9±2.9 ms(p<0.0001)。
  • T1图与T2图分别检出51.1%与65.9%患者的水肿,差异源于T1图伪影。
  • 25.5%患者冠脉造影有阻塞性病变但CMR无水肿,12.8%患者无阻塞性病变但CMR见水肿。

核心结论

  • 在不可忽视比例的NSTEMI患者中,T1与T2 mapping可检出无冠脉显著狭窄者的心肌水肿,反之亦然;冠脉造影与CMR水肿成像在NSTEMI评估中可能提供互补信息。

研究设计与样本

  • 研究论文;47例急性NSTEMI患者,在血运重建前于1.5 T行心脏磁共振检查,包括T1与T2 mapping,并以冠状动脉造影为参照评估冠状动脉病变。

关键影像表现/征象

  • 梗死心肌在T1图上表现为T1值升高(1151.6±53.5 ms vs 远程心肌958.2±38.6 ms,p<0.0001)。
  • 梗死心肌在T2图上表现为T2值升高(69±6 ms vs 远程心肌51.9±2.9 ms,p<0.0001)。
  • T1图与T2图分别检出51.1%与65.9%患者的水肿,该差异归因于T1图的伪影。
  • 6例水肿阳性且冠脉多支阻塞性病变患者中,CMR显示心肌水肿的血管分布区与冠脉造影推测的罪犯病变所在区域不同。

诊断标准与关键数值

  • 以远程心肌为参照,梗死心肌T1值1151.6±53.5 ms vs 958.2±38.6 ms、T2值69±6 ms vs 51.9±2.9 ms,两者p<0.0001。
  • 冠状动脉造影显示阻塞性冠心病36例(80%)、非阻塞性冠心病11例(20%)。
  • 冠脉造影阻塞性病变且CMR见水肿者占53.2%,非阻塞性病变且无水肿者占8.5%。
  • 冠脉造影阻塞性病变但CMR无水肿者占25.5%,非阻塞性病变但CMR见水肿者占12.8%。

临床应用与阅片要点

  • 作者认为,冠脉造影与CMR水肿成像在NSTEMI评估中可能提供互补信息。

局限性

  • T1图存在伪影,导致T1图与T2图检出水肿的比例不同(51.1% vs 65.9%)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIMS: To test T1 and T2 mapping in the assessment of acute myocardial injury in patients with non-ST-segment elevation myocardial infarction (NSTEMI), evaluated before revascularization.

METHODS: Forty-seven patients with acute NSTEMI underwent cardiac magnetic resonance (CMR) at 1.5 T, including T1 and T2 mapping.

RESULTS: Coronary angiography (CA) evidenced an obstructive coronary artery disease (CAD) in 36 patients (80%) and a non-obstructive CAD in 11 patients (20%). Edema was detected in 51.1/65.9% of patients in T1/T2 maps, respectively. This difference was due to artifacts in T1 maps. T1/T2 values were significantly higher in the infarcted myocardium (IM) compared with the remote myocardium (RM) (in T1: 1151.6 ± 53.5 ms vs. 958.2 ± 38.6 ms, respectively; in T2: 69 ± 6 ms vs. 51.9 ± 2.9 ms, respectively; p < 0.0001 for both). We found both an obstructive CAD at CA and myocardial edema at CMR in 53.2% of patients, while 8.5% of patients had a non-obstructive CAD and no edema. However, 25.5% of patients had an obstructive CAD without edema, while 12.8% of patients showed edema despite a non-obstructive CAD. Furthermore, in 6 of the edema-positive patients with multi-vessels obstructive CAD, CMR identified myocardial edema in a vascular territory different from that of the lesion supposed to be the culprit at CA.

CONCLUSIONS: In a non-negligible percentage of NSTEMI patients, T1 and T2 mapping detect myocardial edema without significant stenosis at CA and vice versa. Therefore, CA and CMR edema imaging might provide complementary information in the evaluation of NSTEMI.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Tessa C, Del Meglio J, Lilli A, et al. T1 and T2 mapping in the identification of acute myocardial injury in patients with NSTEMI. Radiol Med. 2018. PMID: 30132183. doi:10.1007/s11547-018-0931-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。